Márcio de Carvalho Formiga

Dr. Márcio de Carvalho Formiga

Periodontology and Oral Implantology, Universidade do Vale do Itajaí, Itajaí, Santa Catarina, Brazil
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Brazilian Oral Research
Verified
Journal Article
Open access
PDF file
Belen Retamal-ValdesBelen Retamal-Valdes
Belen Retamal-Valdes
MFMárcio de Carvalho Formiga
Márcio de Carvalho Formiga
MAMariana Linhares Almeida
Mariana Linhares Almeida
AFAretuza Fritoli
Aretuza Fritoli
KFKadmo Azevedo Figueiredo
Kadmo Azevedo Figueiredo
MFMagda Feres
Magda Feres
The aim was of this study was to determine the current weight of evidence for the existence of specific differences between the microbiota of healthy teeth and healthy implants, or of teeth with periodontitis and implants with peri-implantitis. A systematic review was conducted according to the PRISMA statement. The MEDLINE, EMBASE and Cochrane databases were searched up to February 2018 for studies comparing microbiological data of biofilm samples collected from healthy teeth and implants or from teeth with periodontitis and implants with peri-implantitis. The weight of evidence was defined in three categories (strong, moderate and mild/some), according to the difference in number of studies showing statistically significantly higher counts and/or proportions and/or abundance and/or prevalence of microorganisms in health or in disease. Of the 132 articles identified, 8 were included. A wide range of microorganisms were present in different conditions but no microorganisms showed strong, moderate or mild/some evidence for a specific association with either teeth or implants. The results of this systematic review indicated that there is insufficient evidence in the literature to support specific differences between microorganisms colonizing teeth and implants, either in health or in disease.

8 September 2019 in Materials
Verified
Journal Article
Open access
PDF file
MFMárcio de Carvalho Formiga
Márcio de Carvalho Formiga
UDUlisses Ribeiro Campos Dayube
Ulisses Ribeiro Campos Dayube
CCCristiane Kern Chiapetti
Cristiane Kern Chiapetti
DFDaniela de Rossi Figueiredo
Daniela de Rossi Figueiredo
Jamil Awad ShibliJamil Awad Shibli
Jamil Awad Shibli
When alveolar preservation procedures are not performed after tooth extraction, aesthetic and functional impairment could occur. Guided bone regeneration using polytetrafluoroethylene (PTFE) membranes has proven to be a simple alternative treatment that results in good maintenance of the alveolar bone for mediate/late implant placement. Therefore, this study compared the effect of alveolar preservation with the use of dense PTFE membranes, with and without xenograft material by Computerized tomography-based body composition (CTBC) analysis, after four months of the socket preservation procedure. A total of 29 teeth indicated for extraction. In the test group, the sockets were filled with bone graft biomaterial and subsequently coated with a dense PTFE membrane. In the control group, the sockets were filled with the blood clots and subsequently coated with a dense PTFE membrane. The results we found on the changes of the bone width and height after the procedures were: buccal plate: control group 0.46 mm, test group 0.91 mm; alveolar height: control group −0.41 mm, test group 0.35 mm; cervical third: control group −0.89 mm, test group −0.11 mm; middle third: control group −0.64, test group −0.50; and apical third: control group 0.09 mm, test group −0.14 mm. The use of a xenograft in conjunction with d-PTFE membranes proved to be superior to the use of the same membrane and blood clot only in regions of the crest, middle third, and alveolar height.

15 May 2022 in Materials
Verified
Journal Article
Open access
PDF file
MFMárcio de Carvalho Formiga
Márcio de Carvalho Formiga
Kinga Grzech-LeśniakKinga Grzech-Leśniak
Kinga Grzech-Leśniak
VMVittorio Moraschini
Vittorio Moraschini
Jamil Awad ShibliJamil Awad Shibli
Jamil Awad Shibli
RNRodrigo Neiva
Rodrigo Neiva
Osseodensification is a new method of bone instrumentation for dental implant placement that preserves bulk bone and increases primary implant stability, and may accelerate the implant rehabilitation treatment period and provide higher success and survival rates than conventional methods. The aim of this retrospective study was to evaluate and discuss results obtained on immediate implant placement with immediate and delayed loading protocols under Osseodensification bone instrumentation. This study included private practice patients that required dental implant rehabilitation, between February 2017 and October 2019. All implants were placed under Osseodensification and had to be in function for at least 12 months to be included on the study. A total of 211 implants were included in the study, with a 98.1% total survival rate (97.9% in the maxilla and 98.5% in the mandible). For immediate implants with immediate load, 99.2% survival rate was achieved, and 100% survival rate for immediate implant placement without immediate load cases. A total of four implants were lost during this period, and all of them were lost within two months after placement. Within the limitations of this study, it can be concluded that Osseodensification bone instrumentation provided similar or better results on survival rates than conventional bone instrumentation.

1 January 2020 in Case Reports in Dentistry
Verified
Journal Article
Open access
PDF file
BMBruno Freitas Mello
Bruno Freitas Mello
MFMárcio de Carvalho Formiga
Márcio de Carvalho Formiga
LSLuiz Fernando De Souza Da Silva
Luiz Fernando De Souza Da Silva
GCGustavo Dos Santos Coura
Gustavo Dos Santos Coura
JSJamil Awad Shibli
Jamil Awad Shibli
The guided bone regeneration (GBR) technique has been used to achieve optimal bone volume augmentation and allow dental implant placement in atrophic maxilla and mandible, with predictable results and high survival rates. The use of bone substitutes has reduced the necessity of autogenous bone grafts, reducing the morbidity at the donor areas and thus improving the patients’ satisfaction and comfort. This clinical case report shows a clinical and histological evaluation of the bone tissue behavior, in a case that required the horizontal augmentation of the alveolar ridge, with the use of xenograft biomaterial and further dental implant placement. After six months of healing time, six implants were placed, and a bone biopsy was done. The histological analysis depicted some fragments of the xenograft bone graft, integrated with the new‐formed bone tissue.

Verified
Journal Article
Open access
PDF file
MFMárcio de Carvalho Formiga
Márcio de Carvalho Formiga
HSHélio Doyle Pereira da Silva
Hélio Doyle Pereira da Silva
BGBruna Ghiraldini
Bruna Ghiraldini
RSRafael Shinoske Siroma
Rafael Shinoske Siroma
Lavinia Cosmina ArdeleanLavinia Cosmina Ardelean
Lavinia Cosmina Ardelean
Jamil Awad ShibliJamil Awad Shibli
Jamil Awad Shibli
Primary stability is an important factor for dental implant success. In the past years, a new method for bone site preparation was introduced, named osseodensification (OD). OD produces a condensation of the trabecular portion of the bone, increasing bone-to-implant contact and primary stability. This study aims to compare the effect of OD in cylindrical and conical implants to conventional instrumentation. A total of forty implants, divided into four groups, were placed in porcine tibia: cylindrical conventional (1a), cylindrical OD (1b), conical conventional (2a) and conical OD (2b). Each implant was measured for implant stability quotient (ISQ), insertion torque (IT) and removal torque (RT). Group 2b showed the higher values for each of the evaluated parameters; groups 1b and 2b showed better results than 1a and 2a, respectively. Regarding the IT and RT, group 1b achieved higher values than group 2a, but not for ISQ. The inter-group comparison showed significant difference between groups 1a vs 2a, 1a vs 2b and 1b vs 2b for ISQ and 1a vs 1b and 1a vs 2b for RT analysis. OD resulted in improved ISQ, IT and RT of both cylindrical and conical implants.

7 October 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MFMárcio de Carvalho Formiga
Márcio de Carvalho Formiga
AGArthur Felipe Gehrke
Arthur Felipe Gehrke
JBJoão Paulo De Bortoli
João Paulo De Bortoli
Sergio GehrkeSergio Gehrke
Sergio Gehrke
Objectives: The aims of this study were to compare the initial implant stability obtained using four different osteotomy techniques in low-density synthetic bone, to evaluate the instrument design in comparison to the implant design, and to determinate a possible correlation between the insertion torque and initial stability quotient (ISQ).Materials and methods: Four groups were identified in accordance with the osteotomy technique used (n = 10 implants per group): group G1, osteotomy using the recommended drilling sequence; group G2, osteotomy using an undersized compactor drill; group G3, osteotomy using an undersized drill; and group G4, osteotomy using universal osseodensification drills. Two polyurethane blocks were used: block 1, with a medullary portion of 10 pounds per cubic foot (PCF 10) and with a 1 mm cortical portion of PCF 40, and block 2, with a medullary of PCF 15 and with a 2 mm cortical portion of PCF 40. Tapered implants of 4 mm in diameter and 11 mm in length were used. The insertion torque (IT) and ISQ were measured. The dimensions of the final instrument used in each group and the dimensions of the implant were used to calculate the total area of each part, and these data were compared.Results: Differences between the four groups were found for IT and ISQ values depending on the technique used for the osteotomy in the two synthetic bone models (p < 0.0001). All groups showed lower values of initial stability in block 1 than in block 2.Conclusions: Undersized osteotomies with instruments designed according to the implant body significantly increased the initial stability values compared to beds prepared with universal drills and using the drilling sequence standardized by the manufacturer.