Ayşe Demir Canbulut

Dr. Ayşe Demir Canbulut


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2025 in Medicina
Verified
Journal Article
Open access
PDF file
BBBersu Bedirhandede
Bersu Bedirhandede
Ayşe Demir CanbulutAyşe Demir Canbulut
Ayşe Demir Canbulut
ETEmre Tokar
Emre Tokar
MTMERVE ÇAKIRBAY TANIŞ
MERVE ÇAKIRBAY TANIŞ
NTNihal Tokar
Nihal Tokar
Background and Objectives: This study aimed to investigate the effect of the intraoral scanner, scanning technique, and implant position on the trueness measured by linear and angular deviations. Materials and Methods: An edentulous maxillary model with four implants was scanned using four intraoral scanners (Trios 5, Trios 3, Primescan, Medit i700) and four scanning techniques (unmodified, composite, eugenol, dental floss). Each intraoral scanner–scanning technique combination was repeated ten times, producing 160 test datasets. Master reference files were generated with a laboratory scanner. Linear and angular deviations were calculated after superimposing each test scan with its master file. A three-way ANOVA followed by Tukey’s HSD test was used to determine statistical differences. Significance was set at p < 0.05. Results: Significant effects of intraoral scanner, scanning technique, and implant position were found for both linear and angular deviations (p < 0.001). Trios 5 showed the highest linear deviation values, although these remained within clinically acceptable limits, while Primescan showed the lowest. Dental floss produced the highest linear and angular deviations, whereas eugenol demonstrated the lowest. Medit i700 demonstrated the lowest angular deviation. Conclusions: All intraoral scanners showed deviations within clinically acceptable thresholds, although Trios 5 showed the highest linear deviation. Among scanning techniques, dental floss resulted in the highest linear and angular deviations. Deviations were lower between adjacent implants and higher across 1–3, 1–4, and 2–4.

19 January 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Ayşe Demir CanbulutAyşe Demir Canbulut
Ayşe Demir Canbulut
ÇÇÇAĞLAYAN SAYLA ÇELİK
ÇAĞLAYAN SAYLA ÇELİK
MTMERVE ÇAKIRBAY TANIŞ
MERVE ÇAKIRBAY TANIŞ
ETEmre Tokar
Emre Tokar
SPSerdar Polat
Serdar Polat
KEKürşat Eser
Kürşat Eser
This study investigates the influence of different sintering protocols and resin cement shades on the optical properties of monolithic zirconia restorations. Zirconia, widely used in dentistry for its superior mechanical strength and esthetic potential, demonstrates phase transformations influenced by stabilizing oxides and processing conditions. While increasing yttria content enhances translucency, it compromises mechanical durability. Factors such as sintering temperature, grain size, porosity, and cement selection further affect translucency parameter, contrast ratio, and opalescence. In this research, 36 zirconia samples were divided into three groups according to sintering procedure performed; conventional, fast, and super-fast sintering. Each was tested with two shades of dual-cure resin cement (yellow and transparent). Optical parameters including translucency parameter (TP), contrast ratio (CR), and opalescence parameter (OP) were measured using a spectrophotometer under controlled conditions. Statistically significant differences in OP values between the conventional sintering protocol and both the rapid and super-fast sintering protocols were found. A statistically significant difference was observed in OP values between the yellow and transparent cement groups. Neither the main effects of the sintering protocol nor the cement type were statistically significant on TP and CR values. However, a statistically significant interaction effect between the sintering protocol and cement type was observed for CR values. The findings highlight that both processing parameters and cement selection interaction play crucial roles in optimizing the TP and CR values of zirconia restorations, enabling improved esthetic outcomes in clinical practice.