Bersu Bedirhandede

Dr. Bersu Bedirhandede

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2026 in Biomimetics
Verified
Journal Article
Open access
PDF file
BTBaris erkut Turk
Baris erkut Turk
BBBersu Bedirhandede
Bersu Bedirhandede
DDDilan Gizem Doğan
Dilan Gizem Doğan
BGBeyza Güney
Beyza Güney
Background/Objectives: Patient-specific subperiosteal implants are increasingly used to treat severely atrophic ridges due to advances in digital planning and additive manufacturing. This study aimed to evaluate the effects of material type and implant configuration on stress distribution in subperiosteal implant systems and to compare their overall biomechanical performance using a multi-criteria decision framework. Methods: A three-dimensional model of a severely atrophic maxilla was reconstructed to simulate four clinical scenarios combining two configurations (one-piece and two-piece) and two materials (titanium and 60% carbon fiber-reinforced polyetheretherketone). Finite element analysis was conducted to assess stress distribution within the implant body, fixation screws, prosthetic framework, and surrounding bone under vertical and oblique loading conditions. Maximum and minimum principal stresses were evaluated in bone, whereas von Mises stresses were calculated for implant components. The resulting biomechanical indicators were subsequently integrated using an entropy weight–TOPSIS multi-criteria decision analysis. Results: Principal stresses in the surrounding bone showed minimal variation between titanium and 60% carbon fiber-reinforced polyetheretherketone across all configurations. Implant configuration had a more pronounced effect on implant body stress. Under oblique loading, the two-piece configuration demonstrated substantially higher implant stresses than the one-piece design, whereas under vertical loading, lower implant stresses were observed in the two-piece configuration. The multi-criteria analysis ranked the one-piece titanium model highest under oblique loading and the two-piece titanium model highest under vertical loading. Conclusions: Implant configuration and loading direction influenced biomechanical behavior more than material selection in patient-specific subperiosteal implants.

28 November 2025 in Medicina
Verified
Journal Article
Open access
PDF file
BBBersu Bedirhandede
Bersu Bedirhandede
Ayşe Demir CanbulutAyşe Demir Canbulut
Ayşe Demir Canbulut
ETEmre Tokar
Emre Tokar
MTMERVE ÇAKIRBAY TANIŞ
MERVE ÇAKIRBAY TANIŞ
NTNihal Tokar
Nihal Tokar
Background and Objectives: This study aimed to investigate the effect of the intraoral scanner, scanning technique, and implant position on the trueness measured by linear and angular deviations. Materials and Methods: An edentulous maxillary model with four implants was scanned using four intraoral scanners (Trios 5, Trios 3, Primescan, Medit i700) and four scanning techniques (unmodified, composite, eugenol, dental floss). Each intraoral scanner–scanning technique combination was repeated ten times, producing 160 test datasets. Master reference files were generated with a laboratory scanner. Linear and angular deviations were calculated after superimposing each test scan with its master file. A three-way ANOVA followed by Tukey’s HSD test was used to determine statistical differences. Significance was set at p < 0.05. Results: Significant effects of intraoral scanner, scanning technique, and implant position were found for both linear and angular deviations (p < 0.001). Trios 5 showed the highest linear deviation values, although these remained within clinically acceptable limits, while Primescan showed the lowest. Dental floss produced the highest linear and angular deviations, whereas eugenol demonstrated the lowest. Medit i700 demonstrated the lowest angular deviation. Conclusions: All intraoral scanners showed deviations within clinically acceptable thresholds, although Trios 5 showed the highest linear deviation. Among scanning techniques, dental floss resulted in the highest linear and angular deviations. Deviations were lower between adjacent implants and higher across 1–3, 1–4, and 2–4.

30 September 2026 in Journal of Prosthodontics
Verified
Journal Article
Closed access
BBBersu Bedirhandede
Bersu Bedirhandede
BGBeyza Güney
Beyza Güney
DDDilan Gizem Doğan
Dilan Gizem Doğan
BTBaris erkut Turk
Baris erkut Turk