Abang Anuar Ehsan

Dr. Abang Anuar Ehsan


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
MUMarjoni Imamora Ali Umar
Marjoni Imamora Ali Umar
AAAnnisa Zahra Ahdaliza
Annisa Zahra Ahdaliza
SESalah El-Bahy
Salah El-Bahy
NANur Aliza
Nur Aliza
SSSiti Naqiyah Sadikin
Siti Naqiyah Sadikin
AUAkrajas Ali Umar
Akrajas Ali Umar
The crystallinity properties of perovskite influence their optoelectrical performance in solar cell applications. We optimized the grain shape and crystallinity of perovskite film by annealing treatment from 130 to 170 °C under high humidity (relative humidity of 70%). We found that the grain size, grain interface, and grain morphology of the perovskite are optimized when the sample was annealed at 150 °C for 1 h in the air. At this condition, the perovskite film is composed of 250 nm crystalline shape grain and compact inter-grain structure with an invincible grain interface. Perovskite solar cells device analysis indicated that the device fabricated using the samples annealed at 150 °C produced the highest power conversion efficiency, namely 17.77%. The open circuit voltage (Voc), short-circuit current density (Jsc), and fill factor (FF) of the device are as high as 1.05 V, 22.27 mA/cm2, and 0.76, respectively. Optoelectrical dynamic analysis using transient photoluminescence and electrochemical impedance spectroscopies reveals that (i) carrier lifetime in the champion device can be up to 25 ns, which is almost double the carrier lifetime of the sample annealed at 130 °C. (ii) The interfacial charge transfer resistance is low in the champion device, i.e., ~20 Ω, which has a crystalline grain morphology, enabling active photocurrent extraction. Perovskite’s behavior under annealing treatment in high humidity conditions can be a guide for the industrialization of perovskite solar cells.

29 June 2021 in OSA Continuum
Verified
Journal Article
Closed access
NANOOR AZIE AZURA MOHD ARIF
NOOR AZIE AZURA MOHD ARIF
AEAbang Anuar Ehsan
Abang Anuar Ehsan
The structure of macrobending fiber optics is an ideal structure for constructing fiber optic sensors. This study presents a new design and implementation of U-shaped fiber optics. The basic geometric parameters of U-shaped fiber optics, such as dimension size or curve radius, are analyzed. The Taguchi method was used to optimize the effects of the control and noise factors with respect to dimension size, loop, wavelength, and core size. The control factors were varied at different levels to achieve a novel sensitivity response optimization of the wavelength and core size. The quality characteristics of the signal-to-noise ratio (larger-the-better characteristics) were used to determine the effect of the control parameters in the data analysis. The data of the sensitivity response was analyzed to predict the performance of the U-shaped fiber optics. Results indicate that, by using the Taguchi method, the best control factor setting involves 2.5 cm × 1.5 cm (dimension size) and 1550 nm (wavelength). The percentage contribution of wavelength is the highest at 67.17%, followed by dimension size (13.31%) and number of loops (11.72%) for the fiber optic core size of 50–9–50 μm. For the 9 μm single-mode fiber optics, the corresponding percentages are 61.48%, 16.64%, and 12.81% for wavelength, dimension size, and number of loops, respectively. The Taguchi methodology is suitable for designing sensor geometry.

17 October 2017 in Solid State Phenomena
Verified
Journal Article
Closed access
PDF file
ARAffa Rozana Abdul Rashid
Affa Rozana Abdul Rashid
WMWan Maisarah Mukhtar
Wan Maisarah Mukhtar
KDKarsono A. Dasuki
Karsono A. Dasuki
AEAbang Anuar Ehsan
Abang Anuar Ehsan
SSSahbudin Shaari
Sahbudin Shaari
The ray tracing of unclad U-shape multimode fiber optic is examined by using Zemax simulation have been proposed. The influence of the geometry of sensing region such as absorbing medium refractive index, n2, shape of fiber and the bending radius is analyzed. Number of analysis ray is determined and the value of n2 is varied at 1, 1.3314, 1.359, 1.36, 1.37 and 1.4. The intensity of light propagate inside the fiber is reducing at high n2 and this graph pattern is supported by experimental result. A U-shaped sensor is used for the analysis because of the sensitivity is higher than straight fiber design due to their higher penetration depth. Zemax simulation shows that the fiber with bending radius 1.5 mm has higher response compared to fiber with radius 2.5 mm.

1 January 2021 in Optica Applicata
Verified
Journal Article
Closed access
NANOOR AZIE AZURA MOHD ARIF
NOOR AZIE AZURA MOHD ARIF
DBDilla Durhya Burhanuddin
Dilla Durhya Burhanuddin
SSSahbudin Shaari
Sahbudin Shaari
AEAbang Anuar Ehsan
Abang Anuar Ehsan

7 April 2021
Verified
Book Chapter
Open access
PDF file
MRMUHAMMAD SYAFIQ BIN RAHIM
MUHAMMAD SYAFIQ BIN RAHIM
AEAbang Anuar Ehsan
Abang Anuar Ehsan
Micro milling process has become an attractive method for the rapid prototyping of micro devices. The process is based on subtractive manufacturing method in which materials from a sample are removed selectively. A comprehensive review on the fabrication of circular and rectangular cross-section channels of microfluidic devices using micro milling process is provided this review work. Process and machining parameters such as micro-tools selection, spindle speed, depth of cut, feed rate and strategy for process optimization will be reviewed. A case study on the rapid fabrication of a rectangular cross section channel of a microflow cytometer device with 200 um channel width and 50 um channel depth using CNC micro milling process is provided. The experimental work has produced a low surface roughness micro channel of 20 nm in roughness and demonstrated a microflow cytometer device that can produce hydrodynamic focusing with a focusing width of about 60 um.

2 October 2023 in Journal of Advanced Research in Applied Sciences and Engineering Technology
Verified
Journal Article
Open access
PDF file
MHMohd Hannas Hosnon
Mohd Hannas Hosnon
NSNOOR ANILIZAWATIMA SULONG
NOOR ANILIZAWATIMA SULONG
AEAbang Anuar Ehsan
Abang Anuar Ehsan
KKKhairul Nisha Mohd. Kharuddin
Khairul Nisha Mohd. Kharuddin
The National University of Malaysia's Micro and Nanoelectronics laboratories were examined to ascertain their comfort levels. Eight laboratories were chosen as the study locations. This study aims to assess the interior air quality at six locations by measuring CO2, formaldehyde CHOH, total volatile organic compound TVOC, PM2.5, indoor temperature, and relative humidity. The thermal comfort evaluation for labs 1, 2, 3, 4, 5, and 7 is between 20.45 and 22.47 °C, which is below the range of DOSH and Ashrae. While the average readings in laboratories 6 and 8 are within the limits allowed at 23,21 °C and 23,75 °C, respectively. Five laboratories were exceeding the upper limit of RH (30–60%) but only three laboratories were still within the maximum level mentioned by the Ashrae standard. RH exceeded the ICOP limit (60%) at 70.3%, 63.7%, 75.4%, 60.6%, 62.8% and 65.5%, at Lab 1, 2,3,6,7 and 8, respectively, whereas temperature exceeded it (22.5- 26 °C) at 20.45, 22.2, 21.9, 22.43, 21.58 and 22.47 at Lab 1, 2, 3, 4, 5, 7 and 8, respectively. While the average air velocities for all laboratories are 0.17, 0.13, 0.10, 0.16, 0.12, 0.14, 0.15 and 0.09 ms-1, respectively. All the data that has been measured is found to be below the maximum level as recommended by the ASHRAE Standard 55 (2004) of 0.25 ms-1. The indoor air contaminants (CO, CHOH, TVOC, PM2.5, and PM10) met the standard level of ICOP and DOSH except for CHOH approaches ICOP (0.1ppm) at 0.1 and 0.09, at Point 9 and Point 10 for laboratory 3 compared to other laboratories where the concentration obtained is lower. The highest laboratories average concentration of PM2.5 was 13 µg/m3 determined in Lab 3, which was the most actively utilized one because the research activity in this laboratory was working more intensively than the others. As in the study of PM2.5, the highest average PM10 concentration was evaluated in Lab 3 as 36 µg/m3. Based on observations and studies, we find that fresh outdoor air with a complete and good purifier/filter should be used to reduce the concentration of indoor pollutants.