Nanometrology guarantees the dimensional accuracy in nanomanufacturing. As integrated-circuit features shrink progressively, the conventional laser-wavelength traceability system becomes highly susceptible to ambient disturbances and fails to meet in situ production requirements. Referencing a quantized optical-lattice constant, a flattened traceability chain provides higher throughput and enhanced environmental robustness by reducing the number of calibration transfer steps. Its cornerstone is the self-traceable grating. The grating’s pitch is directly traceable to the 7S 3 →7P 40 transition frequency of chromium (Cr) atoms, which provides picometer accuracy. However, this accuracy is vulnerable to thermal expansion. We developed a thermo-mechanical coupling model to quantify temperature effects and analyze the pitch expansion. This model was validated by finite element simulation (FES). The analysis reveals a cooperative mechanism for stress relief. This mechanism involves interfacial constraints caused by the thermal expansion coefficient (CTE) mismatch between the substrate and the atomic layer. These constraints work in concert with a buffer layer to relieve stress. Within (20 ± 5) °C, the pitch expansion of a 212.78 nm Cr grating decreases from 0.5 to 0.04 pm °C −1 when silicon substrate is replaced by zero expansion glass. This represents an order-of-magnitude improvement. Pitch expansion scales linearly with buffer layer thickness, albeit with opposite slopes for the two substrates. The proposed model and optimization rules furnish theoretical and engineering guidance for boosting nanometrological precision, and fortifying traceability reliability.
18 November 2025 in Measurement Science and Technology
The pitch of chromium atomic lithography gratings (CALGs) is directly traced to the Cr atomic transition frequency, establishing a novel and simplified traceability chain for nanometrology. However, the pitch accuracy of CALGs during dynamic applications as displacement sensors has not yet been rigorously validated. To address this gap, this study proposes a dynamic phase comparison method that combines an iodine-stabilized 633 nm laser interferometer with a grating interferometer to measure the grating pitch. This method synchronously acquires signals from both interferometers during motion and determines the phase proportionality coefficient via linear regression. It further incorporates correction models for cosine errors and thermal expansion effects, enabling high-precision dynamic pitch measurement. Experimental results show that three CALG samples fabricated on zero-expansion glass substrates exhibit a maximum pitch deviation of only 0.6 pm, indicating outstanding pitch uniformity. These results are in strong agreement with both the diffraction-based calibration values reported by the National Institute of Standards and Technology and the theoretical pitch value of CALGs, thereby confirming nanoscale consistency between the traceability chains based on the 633 nm laser and the Cr atomic transition frequency. Furthermore, the pitch variation was found to be less than 1 nm over a 3 mm travel range. This study presents, for the first time, a dynamic metrological validation of the CALG pitch, pushing the measurement uncertainty into the sub-picometer level. These findings provide critical metrological support for implementing CALG-based interferometers in dynamic, high-precision measurement applications, such as advanced lithography systems and nanopositioning stages.
9 February 2026 in IEEE Transactions on Instrumentation and Measurement
Accurate nanoscale calibration of linear encoders is essential for precision manufacturing and inspection. The conventional calibration method uses laser interferometric comparators, but these are susceptible to environmental disturbances and uncertainties in air refractive index compensation, making it challenging to achieve both operational convenience and high-accuracy traceability. To address this problem, a novel grating interferometric comparator based on chromium atomic lithography (CAL) gratings is proposed. Using the grating pitch as the reference, this comparator eliminates refractive index corrections, thereby enhancing robustness and ease of use. The grating pitch is determined by the 7S${}_{3}\!\to ^{7}$ P4 Cr atomic transition frequency, which is directly traceable to the SI with a relative standard uncertainty of $3.7\times 10$ –8. To validate the performance of the proposed comparator, a dual traceability chain comparison system was established, integrating a CAL grating interferometer (CGI) and a stabilized laser interferometer (SLI) for synchronous calibration of linear encoder baseline errors. Experiments demonstrated that the two calibration methods showed good agreement within a travel range of 3 mm, with a maximum deviation of 1.9 nm. Furthermore, the CGI exhibited smaller standard deviations and superior repeatability. The expanded uncertainty of the novel comparator is $U$ (${k} =2$ ) = 2.7 nm $+{\,}8.6\times 10^{\mathrm {-8 }}$ L, where $L$ is in meters. This study provides a traceable and interference-resilient calibration solution for linear encoders, offering strong potential for industrial nanometrology.
Periodic nonlinear error (PNE) is a key factor limiting the accuracy of displacement measurement instruments. For grating interferometers, which are widely used in high-precision displacement measurement, reliable characterization of PNE is essential. Conventional evaluation methods that rely on higher-precision instruments become unsuitable for ultra-high-accuracy systems. Although the self-evaluation method based on Lissajous figures are commonly used, their results inherently depend on the grating parameters and the interferometric signals themselves, leading to a lack of traceability and reduced credibility of the results. In this work, we propose a traceable self-evaluation method for assessing the PNE of a directly traceable grating interferometer (DTGI). The DTGI employs a chromium (Cr) atom lithography grating, whose pitch is directly traceable to the atomic transition frequency of Cr (7S3 → 7P4), as its displacement reference, thereby overcoming the traceability deficiencies of conventional self-evaluation methods. Numerical simulations confirm the validity of the proposed method, and experiments performed on a laboratory-built DTGI demonstrate 10-picometer-level PNE after Heydemann correction within micrometer range displacements. These results confirm the method’s suitability for metrological applications requiring stringent linearity performance in nanometric displacement measurement.
In the era of Atomic and Close-to-Atomic Scale Manufacturing (ACSM), the dimensional stability of ultra-precision systems approaches physical limits, rendering precise measurement of the coefficient of thermal expansion (CTE) critical. Yet, existing methods remain fundamentally constrained by reliance on absolute length measurements susceptible to environmental drift. Here, we introduce the Grating Interferometer Phase Ratio (GPR) method, which bypasses absolute displacement by leveraging a dimensionless phase ratio between a thermally stable reference and a temperature-controlled test grating under synchronous motion. This ratiometric architecture intrinsically decouples cosine, grating scale, and boundary truncation errors while effectively suppressing the influence of periodic nonlinearities. Validation on single-crystal silicon over 30–90 °C yields an average CTE of 2.731×10-6 °C-1 deviating <0.3% from laser absolute methods. Notably, despite a compact 2-millimeter scan, the method achieves an uncertainty of 3×10-9 °C-1. This approach establishes a robust paradigm for ultra-precision thermomechanical characterization, overcoming the physical limits of traditional displacement metrology.