Mengdi Zhang

Mengdi Zhang

Auto-generated profile, based on publicly available information

Mengdi Zhang

National Metrology and Testing Center for Integrated Circuit Measurement and Inspection Equipment Industry (Shanghai), Shanghai, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2023 in IEEE Photonics Journal
Verified
Journal Article
Open access
MZMengdi Zhang
Mengdi Zhang
JWJianxiang Wen
Jianxiang Wen
YWYan Wu
Yan Wu
YCYing Cao
Ying Cao
YLYanhua Luo
Yanhua Luo
TWTingyun Wang
Tingyun Wang
We theoretically and experimentally proposed the generation method of third-order orbital angular momentum (OAM) modes with reduced losses by cascading two adiabatic mode selective couplers (MSCs), in which the LP11 mode produced as an excitation mode was utilized to generate a higher-order mode (LP31). The minimum excess loss and insertion loss of cascaded MSCs were 3.7 dB and 5.3 dB, and had been greatly reduced compared to a single MSC. Then, the third-order OAM mode turned from LP31 mode was amplified in an all-fiber system, by which maximum mode gain after amplification can be achieved up to 23.2 dB. This generation and amplification system has promising applications in the long-distance mode division multiplexing technology.

1 January 2021 in Phyton
Verified
Journal Article
Open access
JYJingyuan Yang
Jingyuan Yang
JZJie Zhou
Jie Zhou
JJJiaojiao Jin
Jiaojiao Jin
YLYi Li
Yi Li
XZXia Zhang
Xia Zhang
CZCunyu Zhou
Cunyu Zhou
Huanglian (Coptis chinensis Franch.) is a slow-growing perennial medicinal herb with considerable economic value. This study aimed to determine the structural characteristics and the levels of berberine deposits in the organs and tissues of Huanglian using light and epifluorescence microscopy. The adventitious roots are composed of primary and secondary structures with endodermis, exodermis, and phellem. The rhizome structures are composed of primary and secondary structures with cuticle and phellem. The leaves are composed of sclerenchymatous rings, isolateral mesophyll, and thin cuticles. We detected berberine in the xylem walls of the roots and rhizomes as well as in the sclerenchymatous rings of the petioles. We postulate that as the exodermis is developed, the deposition of berberine in the xylem closest to the root tips may affect water and nutrient absorption and transfer. Leaf blades had a thin cuticle and isolateral mesophyll, suggesting shade tolerance. These structural and histochemical features suggest that Huanglian is adapted to the slow growing nature of a shady environment.

9 February 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CHChunling He
Chunling He
ZLZichao Lin
Zichao Lin
GXGuangxu Xiao
Guangxu Xiao
JWJun Wang
Jun Wang
MZMengdi Zhang
Mengdi Zhang
TLTongbao Li
Tongbao Li
Accurate nanoscale calibration of linear encoders is essential for precision manufacturing and inspection. The conventional calibration method uses laser interferometric comparators, but these are susceptible to environmental disturbances and uncertainties in air refractive index compensation, making it challenging to achieve both operational convenience and high-accuracy traceability. To address this problem, a novel grating interferometric comparator based on chromium atomic lithography (CAL) gratings is proposed. Using the grating pitch as the reference, this comparator eliminates refractive index corrections, thereby enhancing robustness and ease of use. The grating pitch is determined by the 7S ${}_{3}\!\to ^{7}$ P4 Cr atomic transition frequency, which is directly traceable to the SI with a relative standard uncertainty of $3.7\times 10$ –8. To validate the performance of the proposed comparator, a dual traceability chain comparison system was established, integrating a CAL grating interferometer (CGI) and a stabilized laser interferometer (SLI) for synchronous calibration of linear encoder baseline errors. Experiments demonstrated that the two calibration methods showed good agreement within a travel range of 3 mm, with a maximum deviation of 1.9 nm. Furthermore, the CGI exhibited smaller standard deviations and superior repeatability. The expanded uncertainty of the novel comparator is $U$ ( ${k} =2$ ) = 2.7 nm $+{\,}8.6\times 10^{\mathrm {-8 }}$ L, where $L$ is in meters. This study provides a traceable and interference-resilient calibration solution for linear encoders, offering strong potential for industrial nanometrology.