30 August 2023 in IEEE Photonics Journal
We theoretically and experimentally proposed the generation method of third-order orbital angular momentum (OAM) modes with reduced losses by cascading two adiabatic mode selective couplers (MSCs), in which the LP11 mode produced as an excitation mode was utilized to generate a higher-order mode (LP31). The minimum excess loss and insertion loss of cascaded MSCs were 3.7 dB and 5.3 dB, and had been greatly reduced compared to a single MSC. Then, the third-order OAM mode turned from LP31 mode was amplified in an all-fiber system, by which maximum mode gain after amplification can be achieved up to 23.2 dB. This generation and amplification system has promising applications in the long-distance mode division multiplexing technology.
9 February 2026 in IEEE Transactions on Instrumentation and Measurement
Accurate nanoscale calibration of linear encoders is essential for precision manufacturing and inspection. The conventional calibration method uses laser interferometric comparators, but these are susceptible to environmental disturbances and uncertainties in air refractive index compensation, making it challenging to achieve both operational convenience and high-accuracy traceability. To address this problem, a novel grating interferometric comparator based on chromium atomic lithography (CAL) gratings is proposed. Using the grating pitch as the reference, this comparator eliminates refractive index corrections, thereby enhancing robustness and ease of use. The grating pitch is determined by the 7S ${}_{3}\!\to ^{7}$ P4 Cr atomic transition frequency, which is directly traceable to the SI with a relative standard uncertainty of $3.7\times 10$ –8. To validate the performance of the proposed comparator, a dual traceability chain comparison system was established, integrating a CAL grating interferometer (CGI) and a stabilized laser interferometer (SLI) for synchronous calibration of linear encoder baseline errors. Experiments demonstrated that the two calibration methods showed good agreement within a travel range of 3 mm, with a maximum deviation of 1.9 nm. Furthermore, the CGI exhibited smaller standard deviations and superior repeatability. The expanded uncertainty of the novel comparator is $U$ ( ${k} =2$ ) = 2.7 nm $+{\,}8.6\times 10^{\mathrm {-8 }}$ L, where $L$ is in meters. This study provides a traceable and interference-resilient calibration solution for linear encoders, offering strong potential for industrial nanometrology.