Two photon microscopy and optical coherence tomography (OCT) are two standard methods for measuring flow speeds of red blood cells in microvessels, particularly in animal models. However, traditional two photon microscopy lacks the depth of field to adequately capture the full volumetric complexity of the cerebral microvasculature and OCT lacks the specificity offered by fluorescent labeling. In addition, the traditional raster scanning technique utilized in both modalities requires a balance of image frame rate and field of view, which severely limits the study of RBC velocities in the microvascular network. Here, we overcome this by using a custom two photon system with an axicon based Bessel beam to obtain volumetric images of the microvascular network with fluorescent specificity. We combine this with a novel scan pattern that generates pairs of frames with short time delay sufficient for tracking red blood cell flow in capillaries. We track RBC flow speeds in 10 or more capillaries simultaneously at 1 Hz in a 237 µm × 237 µm × 120 µm volume and quantified both their spatial and temporal variability in speed. We also demonstrate the ability to track flow speed changes around stalls in capillary flow and measure to 300 µm in depth.
9 August 2013 in Semiconductor Science and Technology
We present a self-consistent numerical approach to simulate the output characteristics of a mid-infrared quantum cascade laser, taking into account the effects of both effective subband electron temperature (Te) and optical emission. The current–light (I–L) and current–voltage (I–V) characteristics are simulated with and without the effect of Te. The simulation agrees with the reported experimental results. A comparison between the two cases (with and without optical emission) reveals that optical emission helps bring down the subband effective electron temperature.
The global deterioration of water quality due to climate change and industrialization has intensified the need for real-time monitoring systems. In South Korea’s automated water quality monitoring networks, measuring total organic carbon (TOC) and nitrate nitrogen (NO3-N) as a proxy for total nitrogen (TN) is critical; however, conventional analytical instruments face limitations such as high costs, long analysis times, and the need for chemical reagents. In this study, we developed and evaluated a simultaneous TOC and NO3-N measurement method using HASM-4000, a domestically developed optical sensor based on ultraviolet (UV) absorption spectroscopy. The sensor measures absorbance at 254 nm (TOC) and 220 nm (NO3-N) based on the Beer–Lambert law, with signal processing techniques including optical power compensation (OPC) and Binning–Interpolation (BinInterp) applied to enhance measurement accuracy. Calibration using standard solutions demonstrated excellent linear correlations (R2 > 0.99) between actual and estimated concentrations for both TOC and NO3-N, with accuracy and reproducibility validated against standard methods under laboratory conditions. However, performance degradation was observed in turbid mixed samples due to the optical limitations of the 10 mm pathlength, suggesting the need for future improvements such as adopting a 5 mm pathlength and upgrading optical components. The HASM-4000 sensor enables real-time measurement without a reagent, and preliminary testing with river water samples demonstrates its potential to advance Korea’s water quality monitoring infrastructure by reducing dependence on foreign technologies and facilitating network expansion with cost-effective domestic solutions.
We demonstrated highly sensitive detection of explosive dissolved in solvent with a portable spectroscopy system (Q-MACS) by tracing the explosive byproduct, N2O, in combination with a pulsed electric discharge system for safe explosive decomposition. Using Octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), the gas was monitored and analyzed by Q-MACS and the presence of the dissolved explosive clearly detected. While HMX presence could be identified directly in the air above the solutions even without plasma, much better results were achieved under the decomposition. The experiment results give an estimated detection limit of 10 ppb, which corresponds to a 15 pg of HMX.
We demonstrated the all-optical modulation in the optical emission power of a standard middle infrared quantum cascade laser by optically illuminating its front facet with femtosecond near infrared pulse train. The modulation frequency is found up to 10.35 GHz, much faster than the observed laser current response, only 3 GHz.