Xinbo Yao

Dr. Xinbo Yao


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2024 in Buildings
Verified
Journal Article
Open access
PDF file
WMWensheng Mo
Wensheng Mo
GZGaochuan Zhang
Gaochuan Zhang
XYXinbo Yao
Xinbo Yao
QLQianyu Li
Qianyu Li
BDBart Julien DeBacker
Bart Julien DeBacker
This study aims to evaluate the energy-saving potential of passive solar heating systems in diverse global climates and introduce a new indicator, the passive solar heating indicator (PSHI), to enhance the efficiency of building designs. By collecting climate data from 600 cities worldwide through a simulation model, the present study employs polynomial regression to analyze the impact of outdoor temperature and solar radiation intensity on building energy savings. It also uses K-means cluster analysis to scientifically categorize cities based on their energy-saving potential. The findings underscore the benefits of both direct and indirect solar heating strategies in different climates. Significantly, the PSHI shows superior predictive accuracy and applicability over traditional indices, such as the irradiation temperature difference ratio (ITR) and the irradiation degree hour ratio (C-IDHR), especially when outdoor temperatures are close to indoor design temperatures. Moreover, the application of a cluster analysis provides hierarchical guidance on passive heating designs globally, paving the way for more accurate and customized energy-efficient building strategies.

13 January 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YLYang Liu
Yang Liu
ZZZhuoya Zhang
Zhuoya Zhang
YXYanmin Wang Xue
Yanmin Wang Xue
MWMengcheng Wang
Mengcheng Wang
HFHao Fan
Hao Fan
XYXinbo Yao
Xinbo Yao
In industrial and logistics settings, the use of soft and rigid spinal exoskeletons has been increasing. However, under a unified assistance level and comparable work scenarios, systematic comparisons of their effects on users’ thermophysiological responses and subjective thermal perceptions remain limited. Twenty male participants performed manual handling tasks under three load conditions (5, 10, and 15 kg) in three experimental conditions: without the exoskeleton (WEXO), a rigid exoskeleton (REXO), and a soft exoskeleton (SEXO). Metabolic rate, mean skin temperature (MST), thermal comfort vote (TCV), and thermal sensation vote (TSV) were measured. The key findings are as follows: Compared with WEXO, both exoskeletons significantly reduced metabolic rate. Across all loads, SEXO yielded a lower metabolic rate than REXO and showed a more gradual linear increase as the load increased, whereas REXO exhibited a larger rise at 15 kg. Overall, MST was higher in REXO than in SEXO. Wearing an exoskeleton was often associated with increased skin temperature at 5–10 kg, yet MST decreased for both exoskeletons at 15 kg. Subjective ratings further indicated better TCV and TSV with SEXO than with REXO, with the difference more pronounced under higher loads. Taken together, under the conditions of this study, the soft exoskeleton appears to better balance assistive benefits and thermal comfort. Nevertheless, its heat transfer and heat dissipation performance should be further optimized in future designs.

6 July 2026 in Buildings
Verified
Journal Article
Open access
PDF file
XYXinbo Yao
Xinbo Yao
ZQZhi Qiao
Zhi Qiao
YLYang Liu
Yang Liu
MWMengcheng Wang
Mengcheng Wang
JHJunyi Huang
Junyi Huang
CFChangqing Fang
Changqing Fang
Modern residential balconies have the potential to function as passive solar buffer spaces, yet their thermal performance in cold-region high-rise apartments remains insufficiently explored. This study proposes a stepwise glazing–phase change material (PCM) integrated balcony sunspace strategy for a typical high-rise residential apartment in Xi’an, China. Dynamic simulations were conducted to evaluate the effects of balcony orientation, glazing system, PCM melting temperature, and PCM thickness on indoor thermal comfort and annual heating and cooling demand. First, an open living room-connected balcony was used as the benchmark case, and five glazing systems were compared under southwest-, south-, and southeast-facing orientations. Then, based on the optimal glazing system, a 9C–PCM–9C partition wall was introduced between the enclosed balcony sunspace and the living room. The results showed that the optimal glazing system increased the annual thermal comfort ratio by 4.15–5.24 percentage points and reduced annual heating and cooling demand by 13.78–15.80 kWh/m2 and 6.16–7.21 kWh/m2, respectively. Further PCM integration achieved additional improvements, with 21 °C + 30 mm identified as the optimal configuration for all orientations. Compared with the glazing-only case, it increased thermal comfort by 2.05–2.50 percentage points and reduced heating and cooling demand by 4.80–5.10 kWh/m2 and 1.64–1.76 kWh/m2, respectively. The findings provide a practical passive design strategy for climate-responsive balcony sunspaces in cold-region residential buildings.

30 January 2026 in Nanomaterials
Verified
Journal Article
Open access
PDF file
SLShicheng Lu
Shicheng Lu
Youliang ChengYouliang Cheng
Youliang Cheng
MLMengyao Li
Mengyao Li
JCJing Chen
Jing Chen
CFChangqing Fang
Changqing Fang
JFJiamin Fan
Jiamin Fan
In recent years, against the backdrop of increasingly prominent global climate change and environmental issues, high-efficiency cooling technologies and energy-saving materials have become key research focuses. Radiative cooling, which reflects sunlight and emits thermal radiation into outer space, enables passive cooling without energy consumption. The phase separation method has emerged as a promising approach for fabricating porous daytime radiative cooling materials, attracting extensive research interest due to its favorable processability, excellent cooling performance, low cost, and scalability. Based on radiative cooling principles, this review summarizes the preparation methods, structural design, and application fields of porous radiative cooling films fabricated via the phase separation method. Furthermore, it is suggested that phase-separated porous radiative cooling films hold great potential in green buildings, personal thermal management, and food preservation.

27 September 2026 in Buildings
Verified
Journal Article
Open access
PDF file
XYXinbo Yao
Xinbo Yao
SYShuai Yuan
Shuai Yuan
ZQZhi Qiao
Zhi Qiao
YLYang Liu
Yang Liu
MWMengcheng Wang
Mengcheng Wang
CFChangqing Fang
Changqing Fang
This study proposes an orientation-responsive balcony sunspace integrating phase change material (PCM) storage with temperature-controlled mechanical ventilation for high-rise residential buildings. A validated model of a balcony–living-room system in Xi’an was used to evaluate southeast-, south-, and southwest-facing balconies. Phase-change temperature, latent heat capacity, PCM thickness, and ventilation rate were sequentially investigated using annual heating demand, cooling demand, and thermal comfort time ratio as performance indicators. The optimal phase-change temperatures were 26 °C, 27 °C, and 28 °C for the southeast, south, and southwest orientations, respectively, demonstrating the importance of matching PCM properties to orientation-dependent solar exposure. Within the investigated ranges, a latent heat capacity of 300 kJ/kg and a PCM thickness of 30 mm provided the best overall performance. Relative to the optimized PCM-only configurations, mechanical ventilation reduced heating demand by 3.3–5.6% and total thermal demand by 2.0–3.4%, while improving the comfort time ratio by 0.9–1.5 percentage points. Its benefit became limited above 6 ACH. The final integrated configurations reduced total thermal demand by 7.4–11.4% compared with the reference enclosed balconies. These results indicate that PCM contributed most of the overall improvement, whereas temperature-controlled ventilation provided a supplementary enhancement by improving winter solar-heat transfer. The findings provide an orientation-specific design approach for PCM–ventilation integrated balcony sunspaces.