Qidir Maulana Binu Soesanto

Dr. Qidir Maulana Binu Soesanto

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2026 in Catalysts
Verified
Journal Article
Open access
PDF file
Muhammad NurMuhammad Nur
Muhammad Nur
SSSumariyah Sumariyah
Sumariyah Sumariyah
MNMuhammad Waiz Khairi Nizam
Muhammad Waiz Khairi Nizam
HLHarry Lik Hock Lau
Harry Lik Hock Lau
RSRusydi R. Sofian
Rusydi R. Sofian
Anwar UsmanAnwar Usman
Anwar Usman
Microplastics (MPs) have emerged as persistent environmental pollutants with adverse effects on ecosystems and human health. Conventional removal methods, such as filtration and sedimentation, primarily rely on physical separation without addressing the degradation of MPs, leading to their accumulation and the risk of secondary pollution. This review explores the potential of advanced oxidation processes (AOPs), including photocatalysis, electrochemical oxidation, Fenton processes, sulfate radical-based oxidation, sonochemical treatment, ozonation, and plasma technologies, which generate reactive oxygen and nitrogen species capable of promoting polymer chain scission, microbial biodegradation, and the oxidative fragmentation and mineralization of MPs into non-toxic byproducts. Hybrid AOP systems combined with biological treatments or membrane-based filtration are also examined for their effectiveness in degrading MPs, as well as for scalability and the environmental impacts of their byproducts when integrated into existing wastewater treatment systems. The review further discusses challenges related to operational parameters, energy consumption, and the formation of secondary pollutants. By identifying current knowledge gaps and future research directions, this review provides insights into optimizing AOPs and integrations of AOPs with biological treatments or membrane-based processes for sustainable MP remediation and water treatment applications.

21 July 2022 in IEEE Sensors Letters
Verified
Journal Article
Closed access
ADAdhe Dewi
Adhe Dewi
JSJatmiko Endro Suseno
Jatmiko Endro Suseno
QSQidir Maulana Binu Soesanto
Qidir Maulana Binu Soesanto
This research applied the Non-Destructive Testing (NDT) method of the emission gas produced by methanil yellow waste, carbon dioxide (CO2) and hydrogen (H2) gases with TiO2 as catalyst material to detect the concentration of methanil yellow waste using artificial neural network based on microcontroller. This device consists of Arduino UNO, LCD 16x2 I2C, MQ-8 H2 gas sensor, MQ-135 CO2 gas sensor, BH1750 light sensor and DHT11 temperature sensor. The concentration of waste is 5-30 mg/L with variations range 5 mg/L. Meanwhile, the neural network architecture was created using the Matlab R2018a application. The architecture that owned 25 neurons was chosen due to its performance value with an error of $3.98\ \times \ {10}^{ - 25}$ and epoch 165. The result of Artificial Neuron Network (ANN) training on Matlab of 4-25-1 architecture contains error value of 0.024%. The weight and bias values in the training process are programming ANN to Arduino. The testing has an error value of 6.028% and RMSE 0.552. Based on the error values, it shows that the training is reaching closely to the actual value, it can be concluded that the device can work properly and practical to use because it does not take a long to observe.

8 May 2025 in Physics Letters B
Verified
Journal Article
Open access
MIM. Afif Ismail
M. Afif Ismail
CNChrisna Setyo Nugroho
Chrisna Setyo Nugroho
QSQidir Maulana Binu Soesanto
Qidir Maulana Binu Soesanto

9 November 2022 in Journal of Physics and Its Applications
Verified
Journal Article
Open access
PDF file
QSQidir Maulana Binu Soesanto
Qidir Maulana Binu Soesanto
KFKetut Sofjan Firdausi
Ketut Sofjan Firdausi
WWWinarno Winarno
Winarno Winarno
WPWawa Gravelia Permana Prabawa
Wawa Gravelia Permana Prabawa
This paper has carried out active and non-linear optical characterizations of motor vehicle lubricants. The samples used were three two-wheeled vehicle oil with SAE labels: 10W-40, 20W-50, and 10W-30 without pre-treatment. The active optical property (natural polarization) was measured as a function of the polarizer angle without external field interference. Meanwhile, non-linear optical properties (electro-optical polarization) used changes in the polarization of light as a function of the potential difference imposed on the sample. The light sources used were a green pointer laser (532 nm) and a red pointer laser (632 nm). The results showed that the oil has active and non-linear optical properties. The natural polarization characteristic produces two polarization peaks at 30° and 60° on both wavelengths and holds to all samples. It indicates that the dimensions and shape of the molecules in all samples are identical. It is also shown by electro-optical polarization, where the change in polarization acts as a quadratic function of the potential difference with the concentric curves of the three samples, indicating identical molecules. With electro-optical polarization, the total polarization is enhanced without changing the active optical properties in the sample. It gives an advantage for developing this method as a tracer and evaluator of the molecules of other relevant materials.

20 April 2022 in The European Physical Journal Applied Physics
Verified
Journal Article
Closed access
PDF file
AWAsep Yoyo Wardaya
Asep Yoyo Wardaya
ZMZaenul Muhlisin
Zaenul Muhlisin
JSJatmiko Endro Suseno
Jatmiko Endro Suseno
QSQidir Maulana Binu Soesanto
Qidir Maulana Binu Soesanto
MAMuchamad Azam
Muchamad Azam
SHSusilo Hadi
Susilo Hadi
The calculation of the electrode model in the corona plasma discharge case has been carried out using the semi-ellipse line to plane (S-ELTP) configuration model in the air. The final focus of this research is to calculate the (I–V) current–voltage characteristics of the plasmas discharge. Part of the work in the (I–V) characteristics includes computational calculations and carrying out experimental activities. Experimental data include current vs voltage variations that occur at the time of plasma discharge. All the discharge processes are generated by a positive DC voltage source. The arrangement of the geometric configuration of the electrodes consists of two plates in the form of a half ellipse (active electrode) and a rectangular plate (passive electrode) in a mutually perpendicular position. The size variation of the active electrode includes variations of the small and large size plates with each plate having two variations in the distance between the two electrodes. The calculation concept of the electrode model is to insert the certain shape sharpness factor of k in the numerical calculation in the sharp electrode capacitance part. The k factor value is obtained by calculating the fitting between numerical simulation and research data. The research results prove that there is a fairly high level of conformity between numerical simulation and the research data. Simulation calculation for the (I–V) characteristic curve and its level of accuracy used Python GUI Programming.

6 October 2025 in Engineering Research Express
Verified
Journal Article
Closed access
PDF file
ADAdhe Dewi
Adhe Dewi
JSJatmiko Endro Suseno
Jatmiko Endro Suseno
QSQidir Maulana Binu Soesanto
Qidir Maulana Binu Soesanto
This research conducted a datasheet-based calibration study using the MQ-135 sensor and MQ-8 sensor to measure carbon dioxide and hydrogen. The process of digitizing datasheet graphs into numbers that have a relationship between electrical quantities and physical quantities (R versus ppm) is carried out using webPlotDigitizer software. Based on the calculation results, a trendline of the power equation model has been obtained for the MQ-135 gas sensor and MQ-8 gas sensor respectively from the comparison of the x-axis (ADC) and y-axis (PPM), namely y MQ − 135 = 2 × 10 7 x − 3.108 with a value of R MQ − 135 2 = 0.9968 , and y MQ − 8 = 2533 x − 0.746 with a value of R MQ − 8 2 = 0.9875 . Based on the R 2 value or coefficient of determination for each sensor, it shows that the value is close to 1, so this shows that the trendline of the power equation model used matches the sensor datasheet. The equations y MQ − 135 and y MQ − 8 will then be entered into the Arduino IDE program as calibration values for the MQ-135 sensor and MQ-8 sensor to obtain measurement values that are in accordance with the standardized datasheet. To improve accuracy, calibration was also performed using a reference instrument, a Carbon Dioxide Detector for CO 2 and a C-200 Pen-Type Water Quality Meter for H 2 , with average errors of 1.29488% and 29.81805%, respectively. The low error value for CO 2 indicates good compliance, while the high error for H 2 is due to limitations of the reference instrument. This method can be an alternative when resources are limited, provided that the limitations of the instrument are still considered.