Microplastics (MPs) have emerged as persistent environmental pollutants with adverse effects on ecosystems and human health. Conventional removal methods, such as filtration and sedimentation, primarily rely on physical separation without addressing the degradation of MPs, leading to their accumulation and the risk of secondary pollution. This review explores the potential of advanced oxidation processes (AOPs), including photocatalysis, electrochemical oxidation, Fenton processes, sulfate radical-based oxidation, sonochemical treatment, ozonation, and plasma technologies, which generate reactive oxygen and nitrogen species capable of promoting polymer chain scission, microbial biodegradation, and the oxidative fragmentation and mineralization of MPs into non-toxic byproducts. Hybrid AOP systems combined with biological treatments or membrane-based filtration are also examined for their effectiveness in degrading MPs, as well as for scalability and the environmental impacts of their byproducts when integrated into existing wastewater treatment systems. The review further discusses challenges related to operational parameters, energy consumption, and the formation of secondary pollutants. By identifying current knowledge gaps and future research directions, this review provides insights into optimizing AOPs and integrations of AOPs with biological treatments or membrane-based processes for sustainable MP remediation and water treatment applications.
11 June 2021 in Ultima Computing : Jurnal Sistem Komputer
Pada penelitian ini telah berhasil membuat sebuah alat uji karakterisasi bias maju dioda menggunakan ADC dan DAC internal mikrokontroler ESP32. Tegangan keluaran DAC ditambahkan dengan rangkaian penguat op-amp tak membalik LM358 sebesar 2 kali. Sehingga hasil pengujian tegangan keluaran DAC dapat mencapai nilai maksimum 6,3 volt sebagai sumber catu daya DC variabel rangkaian uji karakteristik bias maju dioda. Pengujian karakterisasi bias maju dioda dilakukan melalui antarmuka perangkat smartphone android dengan jaringan WiFi dan diperoleh kurva grafik karakterisasi bias maju yang memiliki nilai dan bentuk hampir sama dengan pengujian secara manual. Pengujian karakterisasi bias maju dioda menggunakan aplikasi ini lebih cepat daripada menggunakan pengukuran secara manual dengan alat ukur multimeter. Berdasarkan pengujian yang dilakukan menggunakan aplikasi smartphone android sebanyak 3 kali diperoleh rata-rata waktu sebesar 30 detik, sedangkan secara manual menggunakan alat ukur diperoleh rata-rata waktu sebesar 657,7 detik.
20 April 2022 in The European Physical Journal Applied Physics
The calculation of the electrode model in the corona plasma discharge case has been carried out using the semi-ellipse line to plane (S-ELTP) configuration model in the air. The final focus of this research is to calculate the (I–V) current–voltage characteristics of the plasmas discharge. Part of the work in the (I–V) characteristics includes computational calculations and carrying out experimental activities. Experimental data include current vs voltage variations that occur at the time of plasma discharge. All the discharge processes are generated by a positive DC voltage source. The arrangement of the geometric configuration of the electrodes consists of two plates in the form of a half ellipse (active electrode) and a rectangular plate (passive electrode) in a mutually perpendicular position. The size variation of the active electrode includes variations of the small and large size plates with each plate having two variations in the distance between the two electrodes. The calculation concept of the electrode model is to insert the certain shape sharpness factor of k in the numerical calculation in the sharp electrode capacitance part. The k factor value is obtained by calculating the fitting between numerical simulation and research data. The research results prove that there is a fairly high level of conformity between numerical simulation and the research data. Simulation calculation for the (I–V) characteristic curve and its level of accuracy used Python GUI Programming.
1 January 2022 in Gazi University Journal of Science
Research on corona plasma discharges from plasma reactors has been carried out using the Point and Semicircular-Plane (PSC-P) electrode configuration in the air. The purpose of this study is to compare the suitability level of the current-voltage (I-V) characteristics curve from the results of experimental data and numerical simulation calculations of the electrode geometry function based on the variation of three electrode configuration sizes (small plate, medium plate, and large plate) and two variations of the distance between the two electrodes in each electrode configuration size. The results of the study prove that there is a high degree of conformity between numerical calculations with experimental data through calculations from the Python GUI Programming by taking a fitting value from the certain k-shape sharpness factor. The calculation location of the kshape sharpness factor lies on the electrode tip sharp surface which will produce the largest plasma flow in the plasma reactor equipment.
1 July 2023 in Indonesian Journal of Electrical Engineering and Computer Science
A method to calculate a corrected effective diameter (DMIL) to more accurately estimate the dose received by a patient in chest computed tomography (CT) examination had been previously proposed. However, the discrepancy between DMIL and water-equivalent diameter (Dw) is still relatively high (i.e. about 6%). Furthermore, the method is still performed manually, so it is laborious and time-consuming. This study aims to improve the corrected effective diameter with bone correction (Deffcorr) and to automatically calculate it. The automated Deffcorr was calculated as the square root of the product of these corrected AP and LAT diameters. The approach was implemented on 30 patients who had undergone chest CT examination with the standard protocol. The results show that the correlation between the Deffcorr and Dw is R2=0.93 with no statistical difference (p>0.05). The automated Deffcorr is 3.1% lower than Dw. While the DMIL is 10.5% higher than Dw and both are statistically different (p<0.05). In conclusion, the new Deffcorr was introduced and the result obtained was closer to Dw than DMIL. This method is simple enough to be used as an alternative method to accurately estimate Dw for radiation dose estimation in clinical chest CT scanning.
24 May 2021 in Journal of Physics and Its Applications
This researchaimed to obtain Dielectric Barrier Discharge plasma discharge characteristics with and without the placement of natural silkBombyx Mori on one of the electrodes. Furthermore, the strength and the water absorption time of the irradiated silk samples will be analyzed. Plasma discharge is generated by connecting electrodes of point-to-plane configuration with a sheet of glass inserted on the plane electrode at atmospheric conditions. The characterization of plasma discharge, either with or without the natural silk samples' placement on the plane electrode, was performed by increasing A.C.'s high voltage power source to reach arch discharge. Theelectrode spacing varied from 0.7 cm to 2.5 cm with a 0.3 cm increment. Sample irradiation was performed using cold plasma for 5, 15, and 30 minutes respectively. Placing or not placing the natural silk samples on the plane electrode will increase the plasma's discharge current and increase the high voltage. Moreover, increasing the distance between the electrodes and placing the sample on the plane electrode decreases the discharge current. Using Scanning Electron Microscopy, it was found that increasing plasma irradiation time on samples decreases the silk thread'sdiameterand shortening its water absorption time. The strength of irradiated fabric was reduceduntil 15 minutes of irradiation. However, at 30 minutes of irradiation, there was an increase in sample thickness compared to control samples.