Olga Dr Lavrova

Dr. Olga Dr Lavrova

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2016
Verified
Conference Paper
Open access
MRMatthew Reno
Matthew Reno
JQJimmy E. Quiroz
Jimmy E. Quiroz
OLOlga Dr Lavrova
Olga Dr Lavrova
RBRaymond Byrne
Raymond Byrne
A central control algorithm was developed to utilize photovoltaic system advanced inverter functions, specifically fixed power factor and constant reactive power, to provide distribution system voltage regulation and to mitigate voltage regulator tap operations by using voltage measurements at the regulator. As with any centralized control strategy, the capabilities of the control require a reliable and fast communication infrastructure. These communication requirements were evaluated by varying the interval at which the controller sends dispatch commands and evaluating the effectiveness to mitigate tap operations. The control strategy was demonstrated to perform well for communication intervals faster than the delay on the voltage regulator (30 seconds). The communication reliability, latency, and bandwidth requirements were also evaluated.

30 January 2026 in Energies
Verified
Journal Article
Open access
PDF file
FEFarzaneh Eslami
Farzaneh Eslami
MGManaswini mexico state Gangineni
Manaswini mexico state Gangineni
AEAli Ebrahimi
Ali Ebrahimi
MRMenaka Rathnayake
Menaka Rathnayake
MPMihirkumar Patel
Mihirkumar Patel
OLOlga Dr Lavrova
Olga Dr Lavrova
Hybrid AC/DC microgrids (HMGs) are increasingly recognized as a solution for the transition toward future energy systems because they can combine the efficiency of DC networks with an AC system. Despite these advantages, HMGs still have challenges in protection, cybersecurity, and reliability. Conventional protection schemes often fail due to reduced fault currents and the dominance of power electronic converters in islanded or dynamically reconfigured topologies. At the same time, IEC 61850 protocols remain vulnerable to advanced cyberattacks such as Denial of Service (DoS), false data injection (FDIA), and man-in-the-middle (MITM), posing serious threats to the stability and operational security of intelligent power networks. Previous surveys have typically examined these challenges in isolation; however, this paper provides the first integrated review of HMG protection across three complementary dimensions: traditional protection schemes, cybersecurity threats, and artificial intelligence/machine learning (AI/ML)-based approaches. By analyzing more than 100 studies published between 2012 and 2024, we show that AI/ML methods in simulation environments can achieve detection accuracies of 95–98% with response times under 10 ms, while these values are case-specific and depend on the evaluation setting such as network scale, sampling configuration, noise levels, inverter control mode, and whether results are obtained in simulation, hardware in loop (HIL)/real-time digital simulator (RTDS), or field conditions. Nevertheless, the absence of standardized datasets and limited field validation remain key barriers to industrial adoption. Likewise, existing cybersecurity frameworks provide acceptable protection timing but lack resilience against emerging threats, while conventional methods underperform in clustered and islanded scenarios. Therefore, the future of HMG protection requires the integration of traditional schemes, resilient cybersecurity architectures, and explainable AI models, along with the development of benchmark datasets, hardware-in-the-loop validation, and implementation on platforms such as field-programmable gate array (FPGA) and μPMU.

9 November 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
SPShubhasmita Pati
Shubhasmita Pati
MBMilan Biswal
Milan Biswal
SRSatish J Ranade
Satish J Ranade
OLOlga Dr Lavrova
Olga Dr Lavrova
MRMatthew Reno
Matthew Reno
The application of traveling wave (TW) principles for fault detection in distribution systems is challenging because of multiple reflections from the laterals and other lumped elements, particularly when we consider communication-free applications. In [1], we proposed the use of Shapelets to characterize fault signatures as we move towards a more realistic data-driven solution. The Shapelet can be correlated with the physical characteristics of TW generation process, in contrast to choosing a predefined basis such as Wavelets. This paper is an extension of this work to comprehensively evaluate Shapelets for identifying the fault types, in addition to their locations in single-phase, three-phase, and IEEE 13-bus distribution systems. We also propose using the voltage waveforms instead of the forward waves, which eliminates the need for a CT. The proposed method can identify fault locations within a local region with ≈ 99% accuracy and classify the fault types with an accuracy of over 90%.

1 September 2023
Verified
Report
Open access
PDF file
MRMichael E. Ropp
Michael E. Ropp
OLOlga Dr Lavrova
Olga Dr Lavrova
MRMatthew Reno
Matthew Reno
ESElijah Silva
Elijah Silva
MDMcKendree Anne Densel
McKendree Anne Densel
SRSatish J Ranade
Satish J Ranade
The U.S. Department of Energy's Office of Scientific and Technical Information

18 March 2024 in IET Energy Systems Integration
Verified
Journal Article
Open access
AAAgaba Ame‐Oko
Agaba Ame‐Oko
OLOlga Dr Lavrova
Olga Dr Lavrova
A distribution transformer's thermal operating conditions can impose a limitation on the Hosting Capacity (HC) of an electrical distribution feeder for PV interconnections in the feeder's low‐voltage network. This is undesirable as it curtails PV interconnection of both residential and commercial customers in the secondary networks at a time when there are record numbers of interconnection requests by utilities' customers. The authors analyse the limitations on HC due to transformer loading and degradation considerations. Then, the paper proposes a battery energy storage system (BESS) dispatch strategy that will mitigate the limitation on distribution feeder HC by distribution transformers. Three scenarios of HC were simulated for a test network—HC evaluation without restrictions by the distribution transformer (scenario 1), HC evaluation with restrictions by the distribution transformer (scenario 2), and HC evaluation without restriction by the distribution transformer, and with the implementation of the proposed BESS mitigation strategy (scenario 3). Simulation results show that transformer lifetime is depleted to about 6% of expected lifetime for unrestricted HC in scenario 1. Curtailing the HC by 32% in scenario 2 improves the lifetime to 149% of expected lifetime. Implementing the proposed BESS in scenario 3 improves the transformer lifetime to 127% and increases the HC by 62% above the curtailed value in scenario 2, and by 10% above the original HC in scenario 1. The BESS strategy implementation produced cost savings of 49% and 27% of the transformer cost in scenarios 2 and 3, respectively, due to deferred transformer replacement. Conversely, there is a 1600% replacement cost incurred in scenario 1, which underscores the need for a mitigation strategy. The proposed BESS strategy does not only improve the HC of a distribution feeder but also increases a distribution transformer's lifetime leading to replacement cost savings.

7 May 2025 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
HKHuzaifa Karimjee
Huzaifa Karimjee
SRSatish J Ranade
Satish J Ranade
DRDeepak Ramasubramanian
Deepak Ramasubramanian
OLOlga Dr Lavrova
Olga Dr Lavrova
The increasing penetration of inverter-based resources (IBRs) necessitates a reassessment of current grid practices. Blackstart is one specialized area that has drawn renewed attention due to the capability of grid-forming inverters (GFMIs) to emulate synchronous generators (SG). The ability of IBRs to carry out a blackstart represents a novel concept necessitating deeper investigations, particularly given the constraints of IBRs such as over-current limitations, which affect the energization of non-linear network devices. This paper presents a blackstart case study that uses a GFMI, focusing on the energization of a large unloaded plant transformer. Consequently, a unique inrush is demonstrated, known as a sympathetic inrush between the plant and the inverter medium-voltage (MV) transformer. Subsequently, an alternative method for the execution of soft energization (SE) is introduced using a power plant controller (PPC), eliminating inverter-level control modifications. Furthermore, the impact of employing the SE method on inrush currents is evaluated using the proposed method, and a qualitative analysis is lastly presented comparing SE to the hard switching (HS) blackstart method. Collectively, this paper aims to demonstrate the GFMI's ability, using both the SE and HS methods, to energize transformers which play an important role during a blackstart.