Today, the stability of the electric power grid is maintained through real time balancing of generation and demand. Grid scale energy storage systems are increasingly being deployed to provide grid operators the flexibility needed to maintain this balance. Energy storage also imparts resiliency and robustness to the grid infrastructure. Over the last few years, there has been a significant increase in the deployment of large scale energy storage systems. This growth has been driven by improvements in the cost and performance of energy storage technologies and the need to accommodate distributed generation, as well as incentives and government mandates. Energy management systems (EMSs) and optimization methods are required to effectively and safely utilize energy storage as a flexible grid asset that can provide multiple grid services. The EMS needs to be able to accommodate a variety of use cases and regulatory environments. In this paper, we provide a brief history of grid-scale energy storage, an overview of EMS architectures, and a summary of the leading applications for storage. These serve as a foundation for a discussion of EMS optimization methods and design.
This paper describes the design and implementation of a proof-of-concept Pacific dc Intertie (PDCI) wide area damping controller and includes system test results on the North American Western Interconnection (WI). To damp inter-area oscillations, the controller modulates the power transfer of the PDCI, a ±500 kV dc transmission line in the WI. The control system utilizes real-time phasor measurement unit (PMU) feedback to construct a commanded power signal which is added to the scheduled power flow for the PDCI. After years of design, simulations, and development, this controller has been implemented in hardware and successfully tested in both open and closed-loop operation. The most important design specifications were safe, reliable performance, no degradation of any system modes in any circumstances, and improve damping to the controllable modes in the WI. The main finding is that the controller adds significant damping to the modes of the WI and does not adversely affect the system response in any of the test cases. The primary contribution of this paper, to the state of the art research, is the design methods and test results of the first North American real-time control system that uses wide area PMU feedback.
Ageing of technical systems and machines is a matter of fact. It therefore does not come as a surprise that an energy conversion system such as a wind turbine, which in particular operates under non-stationary conditions, is subjected to performance decline with age. The present study presents an analysis of the performance deterioration with age of a Vestas V52 wind turbine, installed in 2005 at the Dundalk Institute of Technology campus in Ireland. The wind turbine has operated from October 2005 to October 2018 with its original gearbox, that has subsequently been replaced in 2019. Therefore, a key point of the present study is that operation data spanning over thirteen years have been analysed for estimating how the performance degrades in time. To this end, one of the most innovative approaches for wind turbine performance control and monitoring has been employed: a multivariate Support Vector Regression with Gaussian Kernel, whose target is the power output of the wind turbine. Once the model has been trained with a reference data set, the performance degradation is assessed by studying how the residuals between model estimates and measurements evolve. Furthermore, a power curve analysis through the binning method has been performed to estimate the Annual Energy Production variations and suggests that the most convenient strategy for the test case wind turbine (running the gearbox until its end of life) has indeed been adopted. Summarizing, the main results of the present study are as follows: over a ten-year period, the performance of the wind turbine has declined of the order of 5%; the performance deterioration seems to be nonlinear as years pass by; after the gearbox replacement, a fraction of performance deterioration has been recovered, though not all because the rest of the turbine system has been operating for thirteen years from its original state. Finally, it should be noted that the estimate of performance decline is basically consistent with the few results available in the literature.
13 December 2021 in IEEE Transactions on Power Systems
Penetration of renewable energy resources (RERs) in the power grid continues to increase as we strive toward a greener environment for the future. While they have many advantages, most RERs possess little or no rotational kinetic energy, thereby threatening the frequency stability of future power grids. Energy storage systems (ESSs) can be used to mitigate this problem, as they are capable of providing virtual inertia to the system. This paper proposes a novel analytical approach for sizing ESSs to provide inertial support to the grid and maintain frequency stability in presence of RERs. This method analytically estimates the total inertia of the system using probability distributions of the outage states of conventional generators and RERs. RERs are modeled as multi-state units, considering the variability of their output power due to changes in weather conditions and also the forced outages of their equipment. The ESS is utilized to provide virtual inertia to the grid in the form of active power once the estimated system inertia falls below the minimum required during a disturbance. The efficacy of the proposed approach is tested on the IEEE 39 bus system and the results obtained by the analytical approach are validated using Monte Carlo simulation.
1 February 2017 in Energy for Sustainable Development