In order to solve the problem of inadequate confinement provided by traditional rectangular stirrups in concrete square columns under stringent seismic fortification requirements, a spiral stirrup with a better constraint effect was used in the square columns in this study. Through a comprehensive analysis of test results, numerical simulations, and theoretical derivations, the seismic performance and shear capacity calculation methods of concrete square columns confined with five-spiral composite stirrups were investigated. This study provides pertinent technical data to facilitate the engineering application of such columns. The existing low-cycle repeated loading tests of 13 concrete square columns confined with five-spiral composite stirrups were collected and analyzed; some of these specimens were selected for finite element numerical simulation, and the simulation results were compared with the test results. The results indicate that the hysteresis curves and skeleton curves obtained from the numerical simulation agree well with the experimental curves, which verifies the rationality of the numerical simulation model proposed in this paper; post-peak load behavior reveals a pronounced compound confinement effect attributable to the five-spiral stirrups; during mid-to-late loading stages, the tensile stress in small spiral stirrups at intersections with larger spirals escalates rapidly, resulting in maximum transverse confinement within these areas. Based on the validated numerical simulation approach, a comprehensive analysis was performed to investigate the effects of axial compression ratio, shear-span ratio, spacing of small spiral stirrups, and diameter ratio of large-to-small spiral stirrups on the seismic performance of the specimens. The results demonstrate that when the spacing of large and small spiral stirrups is kept consistent, the specimens yield optimal strength and ductility. With the diameter of the central large-spiral stirrup fixed, either an increase or a decrease in the diameter of small spiral stirrups will induce varying degrees of reduction in both strength and ductility of the specimens. Furthermore, the five-spiral reinforced columns achieve the best overall seismic performance when the diameter of the central large spiral stirrup reaches the maximum allowable value for the cross-section, and the diameter of small spiral stirrups is set to one-third that of the large spiral stirrup. Finally, the shear mechanism and influencing factors of the shear capacity of the concrete square columns confined with five-spiral composite stirrups were discussed, and a practical formula for calculating the shear capacity of such columns was proposed.
To investigate the cooling mechanism and temperature field evolution of L-shaped concrete-filled steel tubular (CFST) columns during post-fire water spray cooling, the ISO-834 standard fire curve was adopted as the fire heating condition. On this basis, the initial temperature field for the cooling stage was established based on fire simulation results for different flame coverage thicknesses. A fluid–structure coupled numerical model that comprehensively accounts for radiation, convection, and conduction was then developed using the computational fluid dynamics (CFD) software Fluent. In addition, the discrete phase model (DPM) was employed to simulate droplet transport and heat mass transfer, and a droplet evaporation model was activated to account for latent heat absorption. Meanwhile, the SST k–ω turbulence model was also adopted to systematically simulate the cooling process of L-shaped CFST columns under different spray positions and spray flow rates. The results indicate that, during the spray cooling process, the spray position and spray flow rate are key factors governing the cooling effectiveness. Owing to the geometric asymmetry of the L-shaped cross-section, different spray positions resulted in markedly different cross-sectional temperature distributions. Among them, Position 3 (outer surface of the horizontal limb) exhibited the best overall cooling performance, with the average cooling rate on the sprayed surface reaching a maximum of 1.011 °C/s; this was followed by Position 1 (outer surface of the vertical limb), whereas Position 2 (internal corner region) exhibited a relatively lower cooling rate. Moreover, an increase in the spray flow rate accelerated the cooling of the sprayed surface and reduced the time required to reach the target temperature. During the initial cooling stage, the concrete core continued to absorb heat from the high-temperature steel tube and adjacent high-temperature regions. When the heat input exceeded the heat output, the internal concrete temperature continued to rise. As cooling proceeded, the concrete temperature began to decrease gradually. The thermal resistance at the steel–concrete interface was primarily responsible for the lag in the concrete temperature response. Within the investigated parameter range, the results can provide a reference for post-fire temperature assessment and spray parameter selection for L-shaped CFST columns.
Buried petroleum pipelines with localized defects are vulnerable to blast loading, and an effective damage assessment method for polyurea-reinforced defective pipelines is still lacking. In this study, full-scale blast tests and numerical simulations were combined to investigate the dynamic response and damage characteristics of standard and polyurea-reinforced N80 buried pipelines with localized defects under shallow-buried blast loading. The experimental results showed that, at a scaled distance of 0.23 m/kg1/3, polyurea reinforcement reduced the maximum dent depth from 69 mm to 63 mm, corresponding to a reduction of 8.69%, and decreased the peak overpressure on the blast-facing surface by 23.0% compared with the unreinforced pipeline. Based on the critical dent depth-to-length ratio of 0.072, a pressure–impulse (P–I) damage evaluation curve and its fitted equation were established for engineering assessment. The proposed method establishes a preliminary framework for evaluating blast-induced damage in buried polyurea-reinforced petroleum pipelines with localized defects under the specific tested conditions and provides a preliminary framework and a basis for future research, while its general applicability remains to be further validated. Therefore, this work is explicitly designated as a pilot study that offers initial insights under the tested conditions, and further research is needed to validate its broader applicability.