Ahasanul Hoque

Dr. Ahasanul Hoque

Ph.D. Student, Universiti Kebangsaan Malaysia
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Ahasanul HoqueAhasanul Hoque
Ahasanul Hoque
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
Ali F. AlmutairiAli F. Almutairi
Ali F. Almutairi
TATouhidul Alam
Touhidul Alam
MSMandeep Singh Jit Singh
Mandeep Singh Jit Singh
Nowshad AminNowshad Amin
Nowshad Amin
In this paper, a dual-band metamaterial absorber (MMA) ring with a mirror reflexed C-shape is introduced for X and Ku band sensing applications. The proposed metamaterial consists of two square ring resonators and a mirror reflexed C-shape, which reveals two distinctive absorption bands in the electromagnetic wave spectrum. The mechanism of the two-band absorber particularly demonstrates two resonance frequencies and absorption was analyzed using a quasi-TEM field distribution. The absorption can be tunable by changing the size of the metallic ring in the frequency spectrum. Design and analysis of the proposed meta-absorber was performed using the finite-integration technique (FIT)-based CST microwave studio simulation software. Two specific absorption peaks value of 99.6% and 99.14% are achieved at 13.78 GHz and 15.3 GHz, respectively. The absorption results have been measured and compared with computational results. The proposed dual-band absorber has potential applications in sensing techniques for satellite communication and radar systems.

5 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
Ahasanul HoqueAhasanul Hoque
Ahasanul Hoque
Ali F. AlmutairiAli F. Almutairi
Ali F. Almutairi
Nowshad AminNowshad Amin
Nowshad Amin
This paper presents an oval-shaped sensor design for the measurement of glucose concentration in aqueous solution. This unit cell sensing device is inspired by metamaterial properties and is analytically described for better parametric study. The mechanism of the sensor is a sensing layer with varying permittivity placed between two nozzle-shaped microstrip lines. Glucose aqueous solutions were characterized considering the water dielectric constant, from 55 to 87, and were identified with a transmission coefficient at 3.914 GHz optimal frequency with double negative (DNG) metamaterial properties. Consequently, the sensitivity of the sensor was estimated at 0.037 GHz/(30 mg/dL) glucose solution. The design and analysis of this sensor was performed using the finite integration technique (FIT)-based Computer Simulation Technology (CST) microwave studio simulation software. Additionally, parametric analysis of the sensing characteristics was conducted using experimental verification for the justification. The performance of the proposed sensor demonstrates the potential application scope for glucose level identification in aqueous solutions regarding qualitative analysis.

5 May 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MKMuhammad Amir Khalil
Muhammad Amir Khalil
HWHIN YONG WONG
HIN YONG WONG
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
Ahasanul HoqueAhasanul Hoque
Ahasanul Hoque
SIShabiul Islam
Shabiul Islam
MSMohamed S. Soliman
Mohamed S. Soliman
Metamaterials have gained much attention due to their exciting characteristics and potential uses in constructing valuable technologies. This paper presents a double negative square resonator shape metamaterial sensor to detect the material and its thickness. An innovative double-negative metamaterial sensor for microwave sensing applications is described in this paper. It has a highly sensitive Q-factor and has good absorption characteristics approximately equal to one. For the metamaterial sensor, the recommended measurement is 20 by 20 mm. Computer simulation technology (C.S.T.) microwave studios are used to design the metamaterial structure and figure out its reflection coefficient. Various parametric analyses have been performed to optimize the design and size of the structure. The experimental and theoretical results are shown for a metamaterial sensor that is attached to five different materials such as, Polyimide, Rogers RO3010, Rogers RO4350, Rogers RT5880, and FR-4. A sensor’s performance is evaluated using three different thicknesses of FR-4. There is a remarkable similarity between the measured and simulated outcomes. The sensitivity values for 2.88 GHz and 3.5 GHz are 0.66% and 0.19%, respectively, the absorption values for both frequencies are 99.9% and 98.9%, respectively, and the q-factor values are 1413.29 and 1140.16, respectively. In addition, the figure of merit (FOM) is analyzed, and its value is 934.18. Furthermore, the proposed structure has been tested against absorption sensor applications for the purpose of verifying the sensor's performance. With a high sense of sensitivity, absorption, and Q-factor, the recommended sensor can distinguish between thicknesses and materials in various applications.


30 July 2023 in Optics & Laser Technology
Verified
Journal Article
Open access
NUNajeeb Ullah
Najeeb Ullah
SIShabiul Islam
Shabiul Islam
Ahasanul HoqueAhasanul Hoque
Ahasanul Hoque
WYWong Hin Yong
Wong Hin Yong
MSMohamed S. Soliman
Mohamed S. Soliman
MIMohammad Tariqul Islam
Mohammad Tariqul Islam

30 November 2021 in IEEE Access
Verified
Journal Article
Open access
MIMd. Rashedul Islam
Md. Rashedul Islam
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
Ahasanul HoqueAhasanul Hoque
Ahasanul Hoque
MSMohamed S. Soliman
Mohamed S. Soliman
BBBadariah Bais
Badariah Bais
SASami H. A. Almalki
Sami H. A. Almalki
In this research paper, the sensing capabilities of a tri circle split ring resonator shaped metamaterial is shown within the X-band frequency range for detection of various oil samples both theoretically and experimentally. Mathematical modelling was used to analyze the sensor efficiency for the various oil samples. A new sample holder has been made for the proposed sensor structure, and it showed significant performance. The simulated and measured transmission coefficient has been revealed in this study and monitoring the shift of resonance frequency and sensitivity of the metamaterial sensor for different oil samples. Since the dielectric constants of the oil samples differ, hence the resonance frequency is shifted. The obtained result revealed that the proposed sensor can detect a wide range of liquids, including (i) coconut and extra virgin coconut oils, (ii) olive and extra virgin olive oils, (iii) clean and waste engine oils, (iv) sunflower and canola oils. The resonance frequency has shifted to about 210, 230, 170, and 200 MHz for the above-mentioned oil samples, respectively. The sensitivity of the proposed MTM sensor is −83 dB (mg/L) which is a new analysis and quite significant as a potential sensor structure. Surface current and electric field distributions were used to deduce the sensing process. Since the recommended sensor is cheap and highly sensitive; so, it can be used in a variety of fields, such as detection of various liquids, microfluidic sensing, and industrial applications.