Ali F. Almutairi

Prof. Ali F. Almutairi

Kuwait University
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MHMohammad Lutful Hakim
Mohammad Lutful Hakim
TATouhidul Alam
Touhidul Alam
Ali F. AlmutairiAli F. Almutairi
Ali F. Almutairi
MMMohd Fais Mansor
Mohd Fais Mansor
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
Polarization insensitive metamaterial absorbers (MA) are currently very attractive due to their unique absorption properties at different polarization angles. As a result, this type of absorber is widely used in sensing, imaging, energy harvesting, etc. This paper presents the design and characterization of a dual-band polarization-insensitive metamaterial absorber (MA) for K-band applications. The metamaterial absorber consists of two modified split ring resonators with an inner cross conductor to achieve a 90% absorption bandwidth of 400 MHz (21.4–21.8 GHz) and 760 MHz (23.84–24.24 GHz) at transverse electromagnetic (TEM), transverse electric (TE), and transverse magnetic (TM) mode. Polarization insensitivity of different incident angles for TE and TM mode is also investigated, which reveals a similar absorption behavior up to 90°. The metamaterial structure generates single negative (SNG) property at a lower frequency of 21.6 GHz and double negative property (DNG) at an upper frequency of 24.04 GHz. The permittivity and pressure sensor application are investigated for the proposed absorber, which shows its useability in these applications. Finally, a comparison with recent works is also performed to demonstrate the feasibility of the proposed structure for K band application, like sensor, filter, invasive clock, etc.

30 November 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Ahasanul HoqueAhasanul Hoque
Ahasanul Hoque
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
Ali F. AlmutairiAli F. Almutairi
Ali F. Almutairi
TATouhidul Alam
Touhidul Alam
MSMandeep Singh Jit Singh
Mandeep Singh Jit Singh
Nowshad AminNowshad Amin
Nowshad Amin
In this paper, a dual-band metamaterial absorber (MMA) ring with a mirror reflexed C-shape is introduced for X and Ku band sensing applications. The proposed metamaterial consists of two square ring resonators and a mirror reflexed C-shape, which reveals two distinctive absorption bands in the electromagnetic wave spectrum. The mechanism of the two-band absorber particularly demonstrates two resonance frequencies and absorption was analyzed using a quasi-TEM field distribution. The absorption can be tunable by changing the size of the metallic ring in the frequency spectrum. Design and analysis of the proposed meta-absorber was performed using the finite-integration technique (FIT)-based CST microwave studio simulation software. Two specific absorption peaks value of 99.6% and 99.14% are achieved at 13.78 GHz and 15.3 GHz, respectively. The absorption results have been measured and compared with computational results. The proposed dual-band absorber has potential applications in sensing techniques for satellite communication and radar systems.

8 May 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
Ali F. AlmutairiAli F. Almutairi
Ali F. Almutairi
Kok Beng GanKok Beng Gan
Kok Beng Gan
NMNORBAHIAH BINTI MISRAN
NORBAHIAH BINTI MISRAN
Nowshad AminNowshad Amin
Nowshad Amin
Internet of Things (IoT) based healthcare system is now at the top peak because of its potentialities among all other IoT applications. Supporting sensors integrated with IoT healthcare can effectively analyze and gather the patients’ physical health data that has made the IoT based healthcare ubiquitously acceptable. A set of challenges including the continuous presence of the healthcare professionals and staff as well as the proper amenities in remote areas during emergency situations need to be addressed for developing a flexible IoT based healthcare system. Besides that, the human entered data are not as reliable as automated generated data. The development of the IoT based health monitoring system allows a personalized treatment in certain circumstances that helps to reduce the healthcare cost and wastage with a continuous improving outcome. We present an IoT based health monitoring system using the MySignals development shield with (Low power long range) LoRa wireless network system. Electrocardiogram (ECG) sensor, body temperature sensor, pulse rate, and oxygen saturation sensor have been used with MySignals and LoRa. Evaluating the performances and effectiveness of the sensors and wireless platform devices are also analyzed in this paper by applying physiological data analysis methodology and statistical analysis. MySignals enables the stated sensors to gather physical data. The aim is to transmit the gathered data from MySignals to a personal computer by implementing a wireless system with LoRa. The results show that MySignals is successfully interfaced with the ECG, temperature, oxygen saturation, and pulse rate sensors. The communication with the hyper-terminal program using LoRa has been implemented and an IoT based healthcare system is being developed in MySignals platform with the expected results getting from the sensors.

5 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
MMMd. Zulfiker Mahmud
Md. Zulfiker Mahmud
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
NMNORBAHIAH BINTI MISRAN
NORBAHIAH BINTI MISRAN
Ali F. AlmutairiAli F. Almutairi
Ali F. Almutairi
MCMENGU CHO
MENGU CHO
Globally, breast cancer is reported as a primary cause of death in women. More than 1.8 million new breast cancer cases are diagnosed every year. Because of the current limitations on clinical imaging, researchers are motivated to investigate complementary tools and alternatives to available techniques for detecting breast cancer in earlier stages. This article presents a review of concepts and electromagnetic techniques for microwave breast imaging. More specifically, this work reviews ultra-wideband (UWB) antenna sensors and their current applications in medical imaging, leading to breast imaging. We review the use of UWB sensor based microwave energy in various imaging applications for breast tumor related diseases, tumor detection, and breast tumor detection. In microwave imaging, the back-scattered signals radiating by sensors from a human body are analyzed for changes in the electrical properties of tissues. Tumorous cells exhibit higher dielectric constants because of their high water content. The goal of this article is to provide microwave researchers with in-depth information on electromagnetic techniques for microwave imaging sensors and describe recent developments in these techniques.

25 June 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Saif HannanSaif Hannan
Saif Hannan
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
Ali F. AlmutairiAli F. Almutairi
Ali F. Almutairi
Mohammad Rashed Iqbal FaruqueMohammad Rashed Iqbal Faruque
Mohammad Rashed Iqbal Faruque
In this paper, a wide bandwidth angle- and polarization-insensitive symmetric metamaterial (MM) absorber for X and Ku band is proposed. For both normal and oblique incidence in TEM mode, the proposed unit cell shows high absorption at different polarizing angles due to structural symmetry. A four-fold resonator was introduced in the unit cell to enhance the bandwidth. The performance of the proposed absorber is determined by both full-wave simulations and measurements. The simulated and measured absorptions are almost similar at normal incidence with 94.63%, 95.58%, 97% and 75.58% at 11.31 GHz, 14.11 GHz, 14.23 GHz, and 17.79 GHz respectively. At 45° for these frequencies, the absorptions are 95.47%, 97.2%, 97.12% and 75.29% respectively. For 90°, the absorptions are similar to those for 45° except 98.15% for 14.21 GHz. At all these angles and resonance frequencies, either permittivity or permeability was found negative, as a result, the refractive index was negative revealing metamaterial characteristics of the unit cell. Along with high absorptivity and wide incidence angle insensitivity up to 90°, a total of 1.42 GHz of absorption bandwidth was achieved, which is better than recent similar works with FR4 substrate.

5 January 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MIMohammad Tariqul Islam
Mohammad Tariqul Islam
Ahasanul HoqueAhasanul Hoque
Ahasanul Hoque
Ali F. AlmutairiAli F. Almutairi
Ali F. Almutairi
Nowshad AminNowshad Amin
Nowshad Amin
This paper presents an oval-shaped sensor design for the measurement of glucose concentration in aqueous solution. This unit cell sensing device is inspired by metamaterial properties and is analytically described for better parametric study. The mechanism of the sensor is a sensing layer with varying permittivity placed between two nozzle-shaped microstrip lines. Glucose aqueous solutions were characterized considering the water dielectric constant, from 55 to 87, and were identified with a transmission coefficient at 3.914 GHz optimal frequency with double negative (DNG) metamaterial properties. Consequently, the sensitivity of the sensor was estimated at 0.037 GHz/(30 mg/dL) glucose solution. The design and analysis of this sensor was performed using the finite integration technique (FIT)-based Computer Simulation Technology (CST) microwave studio simulation software. Additionally, parametric analysis of the sensing characteristics was conducted using experimental verification for the justification. The performance of the proposed sensor demonstrates the potential application scope for glucose level identification in aqueous solutions regarding qualitative analysis.