To obtain the closed-form forward kinematics of parallel robots, researchers use algebra-based method to transform and simplify the constraint equations. However, this method requires a complicated derivation that leads to high-order univariate variable equations. In fact, some particular mechanisms, such as Delta, or H4 possess many invariant geometric properties during movement. This suggests that one might be able to transform and reduce the problem using geometric approaches. Therefore, a simpler and more efficient solution might be found. Based on this idea, we developed a new geometric approach called geometric forward kinematics (GFK) to obtain the closed-form solutions of H4 forward kinematics in this paper. The result shows that the forward kinematics of H4 yields an eighth degree univariate polynomial, compared with earlier reported 16th degree. Thanks to its clear physical meaning, an intensive discussion about the solutions is presented. Results indicate that a general H4 robot can have up to eight nonrepeated real solutions for its forward kinematics. For a specific configuration of H4, the nonrepeated number of real roots could be restricted to only two, four, or six. Two traveling plate configurations are discussed in this paper as two typical categories of H4. A numerical analysis was also performed for this new method.
27 June 2014 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
An efficient dynamic modelling approach was presented for planar parallel manipulator with flexible links. To increase the accuracy of the model, an improved curvature-based finite element method (ICFE) was developed for discretisation of the flexible links. Then, a novel approach for analysis of the coupling between rigid-body motion and flexible-body motion was proposed, and compared to the regular geometrical method, the proposed method was accurate and easy to implement. With the aforementioned proposed methods, the Kane equation was integrated to formulate the dynamic model of a 3RRR planar parallel manipulator. Finally, comparison studies were performed to validate the proposed ICFE and the integrated dynamic modelling method. Compared to the regular curvature-based finite element method (CFE), the ICFE exhibits improved accuracy with equivalent degrees of freedom. Additionally, the proposed integrated dynamic model shows a good agreement with the Abaqus model. Therefore, it was concluded that the proposed dynamic modelling method herein was efficient and accurate for parallel manipulators with flexible links, demonstrating reasonable potentials for model based control.
1 February 2024 in Journal of Mechanisms and Robotics
This paper proposes a compact and reconfigurable variable stiffness actuator (VSA) using disc spring which is named as SDS-VSA (symmetrical disc spring variable stiffness actuator). To enhance the actuator’s torque density, symmetric compression springs are integrated into the cam-roller-spring mechanism, and a disc spring combination design is employed instead of conventional springs. The disc spring configuration is tailored to achieve a broader stiffness range within a limited size, aligned with stiffness and dimensional requirements. Subsequently, the dynamics of the cam-roller-spring mechanism are derived. To tackle the challenge of strong coupling dynamics, a decoupled modeling method by introducing mismatched and matched disturbances is proposed. A back-stepping tracking controller and proportional-derivative (PD) controller with feedforward are proposed to track the link-side and stiffness motor-side trajectories, respectively. Tracking experiments under significant stiffness alteration are conduced to verify the performance of the prototype SDS-VSA.
5 January 2012 in Journal of Central South University
Broken bones precise repositioning and distal hole's locking of intramedullary nails are major challenges in orthopaedic surgery. This paper proposes a novel fluoroscopy guided robot-assisted orthopaedic surgery system which called MT-RAOS to assist the surgeons to do this work. In the system, a parallel robot is used to imitate the tact of traditional clinic treatment in long bone fracture reposition, and a serial robot is employed to guide the surgeons to accomplish the locking of intramedullary nails, which are usually used to fix the broken bones in orthopaedic surgery now. All these are going under the guiding of fluoroscopy images, provided by a precise C-Arm X-ray machine. And a teleoperating system, a surgeon console, control software are also developed in HIT-RAOS. The major goals are to assist surgeons to reposition broken bones, to guide the surgeon locking nail, to reduce the surgeon's working time under C-Arm, to do surgery planning and teaching, to improve the accuracy of reposition and rates of successfully locking of intramedullary nails, and so on. All these are realized in this system, which already been proved in clinic body sample trials.