Ergonomics and risk factors for work-related musculoskeletal disorders have been studied extensively in various industry fields. However, only a few decades ago, these issues became a concern in the healthcare sector. Total knee arthroplasty (TKA) is one of the most common procedures performed by orthopaedic surgeons, and it would be desirable to perform it with an ergonomically safer technique. This study evaluated the ergonomic risk of different surgeon positions when performing contralateral TKA using the dominant hand. After the authors defined the four possible surgeon positions according to the most common positions used by surgeons in our environment (position A, on the opposite side of the knee to be operated on; position B, on the same side as the knee to be operated on; position C, with the patient’s legs separated and the surgeon standing between them; and position D, facing the knee to be operated on, at the patient’s feet), we performed an ergonomic analysis using the Rapid Entire Body Assessment (REBA) method. The overall REBA scores (lower score values indicate better ergonomics than higher) were between 7 and 6.5 for position A, between 6.17 and 5.5 for position B, between 5.92 and 5.5 for position C, and between 3.75 and 3.42 for position D. The test–retest and inter-rater reliability values ranged from substantial agreement to almost perfect agreement. Based on the results, we can conclude that the most ergonomic position for a right-handed surgeon to perform a left TKA is facing the left knee, at the patient’s feet (position D).
Recent advances allow the use of Augmented Reality (AR) for many medical procedures. AR via optical navigators to aid various knee surgery techniques (e.g., femoral and tibial osteotomies, ligament reconstructions or menisci transplants) is becoming increasingly frequent. Accuracy in these procedures is essential, but evaluations of this technology still need to be made. Our study aimed to evaluate the system’s accuracy using an in vitro protocol. We hypothesised that the system’s accuracy was equal to or less than 1 mm and 1° for distance and angular measurements, respectively. Our research was an in vitro laboratory with a 316 L steel model. Absolute reliability was assessed according to the Hopkins criteria by seven independent evaluators. Each observer measured the thirty palpation points and the trademarks to acquire direct angular measurements on three occasions separated by at least two weeks. The system’s accuracy in assessing distances had a mean error of 1.203 mm and an uncertainty of 2.062, and for the angular values, a mean error of 0.778° and an uncertainty of 1.438. The intraclass correlation coefficient was for all intra-observer and inter-observers, almost perfect or perfect. The mean error for the distance’s determination was statistically larger than 1 mm (1.203 mm) but with a trivial effect size. The mean error assessing angular values was statistically less than 1°. Our results are similar to those published by other authors in accuracy analyses of AR systems.
Background: Recent advances allow the usage of Augmented Reality (AR) for many medical procedures. We perform different AR-assisted knee surgery techniques using optical surgical navigation with ArUco-type artificial marker sensors. Our study aimed to evaluate the system’s accuracy using an in vitro protocol. We hypothesised that the system’s accuracy was equal to or less than 1mm and 1° for distance and angular measurements, respectively. Methods: Our research was an in-vitro laboratory with a 316 L steel model. We evaluated absolute reliability according to the Hopkins criteria with seven independent evaluators. Each observer measured the thirty palpation points and the trademarks to acquire direct angular measurements on three occasions separated by at least two weeks. Results: The accuracy of the system to assess distances had a mean error of 1.203mm and an un-certainty of 2.062, and for the angular values, a mean error of 0.778° and an uncertainty of 1.438. The intraclass correlation coefficient was for all intra-observer and inter-observer almost perfect or perfect. Conclusions: The mean error for the distance’s determination has been statistically larger than 1mm (1.203mm) but with a trivial effect size. The mean error assessing angular values was sta-tistically minor than 1°. Our results are similar to those published by other authors in accuracy analyses of AR systems.
Musculoskeletal disorders (MSDs) among orthopaedic surgeons are associated with sustained, constrained postures during demanding intraoperative tasks. Total hip arthroplasty (THA) comprises sequential steps that may impose different postural loads on both the surgeon and assistant, yet team-level ergonomic design interventions remain underexplored. This study compared ergonomic risk during primary THA performed through the direct lateral (modified Hardinge) and posterolateral (Moore) approaches and assessed a simple workflow redesign: swapping surgeon and assistant positions during acetabular cup preparation (bottom reaming, perimeter reaming, and cup impaction). In a controlled Sawbones-based simulation using standard THA instruments, eight standardised surgical steps were recorded with 360° photographs. Forty-two postural instances (22 for the surgeon, 20 for the assistant) were analysed. Joint angles were measured with Kinovea and converted to Rapid Entire Body Assessment (REBA) scores; intra- and inter-rater reliability (ICC) and minimum detectable change (MDC95) were calculated. Surgeon REBA scores were in the medium-risk range and slightly lower with the posterolateral approach (mean 5.5) than with the direct lateral approach (mean 5.88), whereas assistant scores were in the low-risk range (means 3.43 and 3.29, respectively). The position-swap intervention successfully lowered the surgeon’s REBA action level, most notably during cup impaction, where ergonomic risk dropped from 10 (high risk) to 4 (medium risk) in the posterolateral approach, and from 7 (medium risk) to 3 (low risk) in the direct lateral approach, without increasing assistant risk. These findings provide controlled simulation-based evidence that this simple, zero-cost positional change can reduce the surgeon’s ergonomic action level during THA, although confirmation under real operative conditions is needed before broad generalization.
Background: Work-related musculoskeletal disorders (WMSDs) are prevalent among orthopaedic surgeons as a result of prolonged exposure to non-neutral postures and forceful manual tasks during surgery. Although working height is a key determinant of trunk and upper-limb posture, the systematic evaluation of ergonomic working-height recommendations in orthopaedic surgery remains limited. Methods: A simulated left total knee arthroplasty (TKA) was divided into twelve critical surgical steps and analysed across four commonly used surgeon positions (A–D). Two conditions were compared: uncorrected working height (N) and working height corrected according to Canadian Centre for Occupational Health and Safety (CCOHS) recommendations (C). Joint angles were measured from standardized photographs using Kinovea software, and postural load was quantified with the Rapid Entire Body Assessment (REBA) method. Two trained evaluators conducted three independent assessments, yielding 288 REBA scores. Results: Mean REBA scores decreased across all surgeon positions following ergonomic correction, with statistically significant reductions observed in positions A, B, and D. When pooled across all position–step combinations (n = 48), the mean reduction was 0.92 REBA points (95% CI 0.50–1.33; p < 0.001). Notably, 27 of the 48 position–step comparisons exceeded the minimal detectable change threshold. The largest reductions occurred during force-intensive surgical steps, including bone cutting, drilling, and implant impaction. Conclusions: Adjusting working height in accordance with CCOHS ergonomic recommendations reduces surgeons’ postural load during TKA. These findings support the integration of evidence-based ergonomic adjustments into routine orthopaedic surgical practice.
22 December 2025 in Journal of Orthopaedics and Traumatology
Periprosthetic femoral fractures following hip arthroplasty (FH-PPF) represent a severe complication, especially in elderly patients with compromised healt