Ergonomics and risk factors for work-related musculoskeletal disorders have been studied extensively in various industry fields. However, only a few decades ago, these issues became a concern in the healthcare sector. Total knee arthroplasty (TKA) is one of the most common procedures performed by orthopaedic surgeons, and it would be desirable to perform it with an ergonomically safer technique. This study evaluated the ergonomic risk of different surgeon positions when performing contralateral TKA using the dominant hand. After the authors defined the four possible surgeon positions according to the most common positions used by surgeons in our environment (position A, on the opposite side of the knee to be operated on; position B, on the same side as the knee to be operated on; position C, with the patient’s legs separated and the surgeon standing between them; and position D, facing the knee to be operated on, at the patient’s feet), we performed an ergonomic analysis using the Rapid Entire Body Assessment (REBA) method. The overall REBA scores (lower score values indicate better ergonomics than higher) were between 7 and 6.5 for position A, between 6.17 and 5.5 for position B, between 5.92 and 5.5 for position C, and between 3.75 and 3.42 for position D. The test–retest and inter-rater reliability values ranged from substantial agreement to almost perfect agreement. Based on the results, we can conclude that the most ergonomic position for a right-handed surgeon to perform a left TKA is facing the left knee, at the patient’s feet (position D).
1 January 2016 in International Journal of Surgery Case Reports
Failed hip arthroplasty with intrapelvic acetabular migration can be challenging due to the potential damage of intrapelvic structures. We present a case of a 75 year-old lady with failed hip arthroplasty with loosening of implants and intra-pelvic migration of the cup, antiprotrusio cage mesh, screws and plate. A modified Stoppa approach was performed, a part of the migrated elements were safely removed, the intrapelvic structures were controlled, and the bone defect was reconstructed through the Stoppa approach combined with the lateral window of ilioinguinal approach by means of bone struts and metallic plates, which is a novel technique. Then an extended posterolateral hip approach was done and the acetabulum was reconstructed using porous tantalum augments and morselized allograft. A cemented constrained socket was implanted. After one-year follow-up the patient is able to walk with one crutch without pain. Due to intrapelvic migration, the implants used in hip arthroplasty may become entrapped between the anatomical structures lodged in the pelvis and cause damage to them. A careful preoperative assessment and planning are mandatory. A migrated socket can be inaccessible through a conventional hip approach and removal could be very difficult and dangerous. The Stoppa approach in hip revision surgery can be a complement to traditional approaches to control the intrapelvic structures, remove migrated implants of previous surgery and reconstruct the pelvic defect.
Introduction. Reconstruction of acetabular bone defects by the combination of trabecular metal augments and porous cups can be complex when extensive bone loss and poor-quality bone exists. The onset of porous cups with an interlocking mechanism may simplify surgical technique due to its superior initial mechanical stability. We endorse the possibility for a change in the classical order of setting of the augments and the cup. Methods. We present a technical modification and a series of cases of three patients with Paprosky IIB and IIIA acetabular defects operated with a combination of porous metal augments and a porous cup. In all the three patients, the setting of the cup was done first and secured with locked screws, and then the augments were set in place as a wedge and fixed with screws in a standard fashion. Results. The postoperative X-ray showed good position of implants with restoration of the center of rotation, and the patients had good recovery. Radiological evaluation in the midterm follow-up did not show mobilization of implants. Discussion. The use of metal porous augments is widely used for severe acetabular defects, being a versatile system to adapt to the different size defects. Nevertheless, its use may be technically demanding and time consuming. It is not infrequent that the setting of the augments conditions the final position of the cup with a possible interference with initial stability and eventually bone ingrowth of the cup. The interlocking mechanism offers an additional biomechanical stability and thus may allow us to place the cup first in the desired position with a less demanding technique. Conclusion. With the use of locked-screw porous metal cups, the order of setting of implants may be changed in order to obtain a better restoration of the center of rotation and increased host-bone implant contact with a simplified surgical technique.
22 December 2025 in Journal of Orthopaedics and Traumatology
Periprosthetic femoral fractures following hip arthroplasty (FH-PPF) represent a severe complication, especially in elderly patients with compromised healt