Francisco Lajara-Marco

Dr. Francisco Lajara-Marco

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2022 in Injury
Verified
Journal Article
Closed access
SCSilvia Correoso Castellanos
Silvia Correoso Castellanos
Francisco Lajara-MarcoFrancisco Lajara-Marco
Francisco Lajara-Marco
EDElena Blay Domínguez
Elena Blay Domínguez
EGEva María Veracruz Gálvez
Eva María Veracruz Gálvez
BPBeatriz Muela Pérez
Beatriz Muela Pérez

30 October 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MRMarina Sánchez Robles
Marina Sánchez Robles
FMFrancisco José Díaz Martínez
Francisco José Díaz Martínez
Vicente Jesús León-MuñozVicente Jesús León-Muñoz
Vicente Jesús León-Muñoz
CMCarmelo Marín-Martínez
Carmelo Marín-Martínez
AAAntonio Murcia Asensio
Antonio Murcia Asensio
Francisco Lajara-MarcoFrancisco Lajara-Marco
Francisco Lajara-Marco
Ergonomics and risk factors for work-related musculoskeletal disorders have been studied extensively in various industry fields. However, only a few decades ago, these issues became a concern in the healthcare sector. Total knee arthroplasty (TKA) is one of the most common procedures performed by orthopaedic surgeons, and it would be desirable to perform it with an ergonomically safer technique. This study evaluated the ergonomic risk of different surgeon positions when performing contralateral TKA using the dominant hand. After the authors defined the four possible surgeon positions according to the most common positions used by surgeons in our environment (position A, on the opposite side of the knee to be operated on; position B, on the same side as the knee to be operated on; position C, with the patient’s legs separated and the surgeon standing between them; and position D, facing the knee to be operated on, at the patient’s feet), we performed an ergonomic analysis using the Rapid Entire Body Assessment (REBA) method. The overall REBA scores (lower score values indicate better ergonomics than higher) were between 7 and 6.5 for position A, between 6.17 and 5.5 for position B, between 5.92 and 5.5 for position C, and between 3.75 and 3.42 for position D. The test–retest and inter-rater reliability values ranged from substantial agreement to almost perfect agreement. Based on the results, we can conclude that the most ergonomic position for a right-handed surgeon to perform a left TKA is facing the left knee, at the patient’s feet (position D).

26 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Vicente Jesús León-MuñozVicente Jesús León-Muñoz
Vicente Jesús León-Muñoz
FSFernando Santonja-Medina
Fernando Santonja-Medina
Francisco Lajara-MarcoFrancisco Lajara-Marco
Francisco Lajara-Marco
ALAlonso J. Lisón-Almagro
Alonso J. Lisón-Almagro
JJJesús Jiménez-Olivares
Jesús Jiménez-Olivares
Joaquin Moya-AngelerJoaquin Moya-Angeler
Joaquin Moya-Angeler
Recent advances allow the use of Augmented Reality (AR) for many medical procedures. AR via optical navigators to aid various knee surgery techniques (e.g., femoral and tibial osteotomies, ligament reconstructions or menisci transplants) is becoming increasingly frequent. Accuracy in these procedures is essential, but evaluations of this technology still need to be made. Our study aimed to evaluate the system’s accuracy using an in vitro protocol. We hypothesised that the system’s accuracy was equal to or less than 1 mm and 1° for distance and angular measurements, respectively. Our research was an in vitro laboratory with a 316 L steel model. Absolute reliability was assessed according to the Hopkins criteria by seven independent evaluators. Each observer measured the thirty palpation points and the trademarks to acquire direct angular measurements on three occasions separated by at least two weeks. The system’s accuracy in assessing distances had a mean error of 1.203 mm and an uncertainty of 2.062, and for the angular values, a mean error of 0.778° and an uncertainty of 1.438. The intraclass correlation coefficient was for all intra-observer and inter-observers, almost perfect or perfect. The mean error for the distance’s determination was statistically larger than 1 mm (1.203 mm) but with a trivial effect size. The mean error assessing angular values was statistically less than 1°. Our results are similar to those published by other authors in accuracy analyses of AR systems.

Verified
Journal Article
Open access
PDF file
Vicente Jesús León-MuñozVicente Jesús León-Muñoz
Vicente Jesús León-Muñoz
JHJosé Hurtado-Avilés
José Hurtado-Avilés
FSFernando Santonja-Medina
Fernando Santonja-Medina
Francisco Lajara-MarcoFrancisco Lajara-Marco
Francisco Lajara-Marco
MLMirian López-López
Mirian López-López
Joaquin Moya-AngelerJoaquin Moya-Angeler
Joaquin Moya-Angeler
Background: The coronal plane alignment of the knee (CPAK) classification categorises nine phenotypes based on constitutional limb alignment and joint line obliquity and can be used in healthy and arthritic knees. In total knee arthroplasty surgery, some morphological variables in planes other than the coronal plane are particularly interesting. One example is the distal femoral rotation. Our study aimed to search for relationships between phenotypes based on CPAK classification and distal femoral rotation. Methods: Data from 622 cases in 535 osteoarthritic patients who underwent primary total knee arthroplasty were retrospectively analysed. Computed tomography imaging was employed to ascertain the mechanical lateral distal femoral angle, the mechanical medial proximal tibial angle, and the distal femoral rotation (quantified using the condylar twist angle). Results: The variables were perfectly uncorrelated according to the regression equations, with a Coefficient of Determination of 0.0608 for the condylar twist angle. Upon visualising the condylar twist angle function using a contour map or surface curves with low interpolation, it became evident that the data did not follow any discernible pattern. Employing ANOVA, we found some statistically significant differences between the distributions of the CPAK groups for the condylar twist angle (F = 5.81; p < 0.001). Conclusions: Our study found no relevant relationships between coronal plane alignment, according to the CPAK classification, and the distal femoral rotation in the sample population studied. Perhaps the stratification of the CPAK groups (i.e., a purely arithmetical aspect) hides possible relationships between the coronal and the axial planes.

21 November 2022 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Closed access
PDF file
JSJose Eduardo Salinas-Gilabert
Jose Eduardo Salinas-Gilabert
JJJesús Jiménez-Olivares
Jesús Jiménez-Olivares
Francisco Lajara-MarcoFrancisco Lajara-Marco
Francisco Lajara-Marco
BMBeatriz Muela-Pérez
Beatriz Muela-Pérez
EVEva María Veracruz-Gálvez
Eva María Veracruz-Gálvez
ACAna Corraliza-Zamorano
Ana Corraliza-Zamorano

8 August 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
Vicente Jesús León-MuñozVicente Jesús León-Muñoz
Vicente Jesús León-Muñoz
FSFernando Santonja-Medina
Fernando Santonja-Medina
Francisco Lajara-MarcoFrancisco Lajara-Marco
Francisco Lajara-Marco
ALAlonso J. Lisón-Almagro
Alonso J. Lisón-Almagro
JJJesús Jiménez-Olivares
Jesús Jiménez-Olivares
Joaquin Moya-AngelerJoaquin Moya-Angeler
Joaquin Moya-Angeler
Background: Recent advances allow the usage of Augmented Reality (AR) for many medical procedures. We perform different AR-assisted knee surgery techniques using optical surgical navigation with ArUco-type artificial marker sensors. Our study aimed to evaluate the system’s accuracy using an in vitro protocol. We hypothesised that the system’s accuracy was equal to or less than 1mm and 1° for distance and angular measurements, respectively. Methods: Our research was an in-vitro laboratory with a 316 L steel model. We evaluated absolute reliability according to the Hopkins criteria with seven independent evaluators. Each observer measured the thirty palpation points and the trademarks to acquire direct angular measurements on three occasions separated by at least two weeks. Results: The accuracy of the system to assess distances had a mean error of 1.203mm and an un-certainty of 2.062, and for the angular values, a mean error of 0.778° and an uncertainty of 1.438. The intraclass correlation coefficient was for all intra-observer and inter-observer almost perfect or perfect. Conclusions: The mean error for the distance’s determination has been statistically larger than 1mm (1.203mm) but with a trivial effect size. The mean error assessing angular values was sta-tistically minor than 1°. Our results are similar to those published by other authors in accuracy analyses of AR systems.