During the first test divertor campaign of the stellarator experiment Wendelstein 7-X (Pedersen et al 2022 Nucl. Fusion62 042022), OP1.2b, 13 neutral gas pressure gauges collected data in different locations in the plasma vessel, enabling a detailed analysis of the neutral gas pressures, the compression ratios and the particle exhaust rates via the turbomolecular pumps in the different magnetic field configurations. In Wendelstein 7-X, the edge magnetic islands are intersected by the divertor target plates and used to create a plasma-wall interface. As the number and position of the magnetic islands varies in different magnetic field configurations, the position of the strike line on the target plates and thus the neutral gas pressure in the subdivertor differs between the configurations. Neutral gas pressures on the order of few 10−4 mbar were measured in the subdivertor region. The highest neutral gas pressure of mbar was obtained in the so-called high iota configuration featuring four edge magnetic islands per cross section. The neutral particle flux through the pumping gaps into the subdivertor volume was provided by EMC3-EIRENE simulations and allowed to analyze the relation between the particle flux entering the subdivertor and the pressure distribution in the subdivertor. Finite element simulations in ANSYS provide a detailed picture of the pressure distribution in the subdivertor volume and agree with the neutral gas pressure measurements in the subdivertor in the standard configuration featuring an island chain of 5 edge magnetic islands. Surprisingly high neutral gas pressures that were not predicted by the simulation were measured in the subdivertor region away from the main strike line for discharges in the most used magnetic configuration, the standard configuration. While the pressure ratio between the two sections of the subdivertor volume, the low and high iota section is 0.06 in high iota configuration, a ratio of 2–5 was obtained in the other configurations, indicating significant particle loads and exhaust rates on the high iota section of the subdivertor in magnetic configurations with the main strike line on the low iota divertor targets.
The present work presents a 2D and 3D modeling of the neutral gas flow in the sub-divertor region of the W7-X. The investigations have been done using the DIVGAS code. The complex 2D and 3D geometries of the divertor components in the sub-divertor region have been considered and the Standard and High-Iota magnetic configurations have been numerically simulated. The main objective of this study is to investigate the dynamics of neutral particles in the sub-divertor region including the effects due to geometry and toroidal and poloidal leakages located at the divertor targets and baffles on the achieved pumping efficiency. A sensitivity analysis has been performed for the effect of various geometrical and flow parameters on the pumping performance, under different plasma scenarios. The considered incoming fluxes in the sub-divertor range between 1020 to 1022 (H2 s−1). The main conclusions, which can be extracted from the present numerical analysis could be summarized as follows; a large fraction of incoming neutral particle flux i.e. >70% on the low iota side and >40% for the high iota side is leaked back to the main divertor region, while higher incoming neutral fluxes facilitate the increase of the pumped flux as well as the decrease of the outflux. It has been estimated that a small fraction ∼3%–4% of the incoming neutral flux is being pumped via the turbo-molecular pumps. The closure of the toroidal leakages as well as the inclination of the pumping gap panel by 9o facilitate the increase of the pumped flux, but considering the all the engineering constraints, the latter option seems to be more easy to be implemented. For low incoming neutral fluxes (∼1020 H2 s−1) and for the case of AEH section, free molecular flow conditions are estimated and therefore neutral-neutral collisions could be neglected. For higher incoming neutral fluxes and for both AEH and AEP sections neutral-neutral collisions play a significant role in the flow establishment. A comparison with available experimental measurements of the neutral pressure in the sub-divertor has been performed for Standard and High-Iota plasma discharges. The 3D DIVGAS simulations predict qualitatively the experimental data with relative deviation between 25 and 63%. All the above numerical findings will actively support the optimization of the W7-X particle exhaust, in view of the experimental campaign OP2.
In the Large Helical Device (LHD) a low temperature mode (LTM) of the helical divertor was discovered. It combines particle detachment and very large sub-divertor pressures up to 1.4 Pa. During the LTM, the electron temperature in the divertor was in the range from 0.25 to 0.42 eV so that volume recombination occurred. This result is remarkable because in the stellarators LHD and Wendelstein 7-X only low sub-divertor pressures (0.03–0.3 Pa) were expected and measured up to now due the loss of pressure conservation along flux tubes by an enhanced cross-field transport. It demonstrates that the more complex, three-dimensional divertors of stellarators can achieve a similar performance with respect to particle exhaust and detachment like the geometrically simpler poloidal divertors in tokamaks even if the favorable effect of flux amplification is absent. The LTM of the helical divertor depends, however, on the magnetic configuration, i.e. on geometry. It was only observed in the inward shifted configuration with m, but not in the more frequently studied configuration with m. A nuclear fusion reactor based on the heliotron concept (DEMO) would benefit from the LTM by the very compact divertor configuration and the excellent performance.
The present work is focused on a 3D numerical assessment of the Wendelstein 7-X (W7-X) particle exhaust. For all the numerical simulations the direct simulation Monte Carlo solver of the DIVGAS workflow, has been employed. The complex 3D geometry of the sub-divertor region includes the pumping gap panel, supporting structures, cooling pipes as well as the cryo-vacuum pump. All the considered flow simulations correspond to the Standard magnetic configuration of W7-X. The main conclusions, which can be extracted from the present numerical analysis could be summarized as follows; The coupling between EMC3-EIRENE and DIVGAS, which considers the fact that the incoming neutral particle flux at the sub-divertor is based on realistic plasma background, has been demonstrated. Three plasma scenarios have been considered, for which is clearly seen that by increasing the heating power, the neutral pressure as well as the resulting pumping efficiency is increased. The obtained numerical results of the neutral pressure in the sub-divertor lie within a more general scan matrix, which assumes a wider range of incoming particle flux, namely 1019–1024 (s−1). It has been observed that, the sub-divertor neutral pressure is proportional to the incoming neutral particle flux, with the effective pumping speed to be a constant of proportionality. The influence of switching off the cryo-vacuum pump on the sub-divertor pressure is rather modest and a weak increase of the neutral pressure in the sub-divertor is expected. Correlations of the sub-divertor pressure with the total incoming particle flux as well as the individual pumped flux at each of the AEH and AEP sections have been deduced. Moreover, it has been demonstrated that the influence of the incoming neutral particle flux on the albedo coefficient at the AEH and AEP pumping gaps is rather weak. All the above numerical findings will actively support the optimization of the W7-X particle exhaust, in view of future experimental campaigns.
11 September 2024 in Fusion Engineering and Design
During deuterium campaigns on the heliotron large helical device (LHD), ITER pressure gauges with different cathode materials were used to measure the neutral pressure in the sub-divertor region. Throughout these campaigns, it was observed that the performance of a LaB6 cathode was unsatisfactory during deuterium operation. Conversely, measurements taken with pressure gauges with a ZrC cathode performed well throughout the deuterium pulses. The ITER pressure gauge with the ZrC cathode could be operated with a very high electron current of 800 µA, thus improving the lower detection limit of the neutral pressure in LHD. With this design it was also possible to avoid jumps in the ion current within strong magnetic fields, improving the accuracy of the measurement from 15% uncertainty to 5%. These features allowed very precise neutral pressure measurements to be made in a fusion device with magnetic confinement. The problems with the lifetime of the ZrC cathode reported in Mackel et al (2023 Fusion Eng. Des.189 113439) were not relevant here, as the total runtime in the magnetic field was about 60 h, less than the expected lifetime of the cathode of 350 h.