Jaskaran Singh

Dr. Jaskaran Singh

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2025 in Global Spine Journal
Verified
Journal Article
Open access
IPIan Polyzois
Ian Polyzois
JSJaskaran Singh
Jaskaran Singh
SGSara Gustafson
Sara Gustafson
TGTrevor Gascoyne
Trevor Gascoyne
MGMichael Goytan
Michael Goytan
Study Design: Basic Science Study. Objective: To determine the impact of splint rods, rod material, and rod diameter on cervicothoracic construct load bearing capacity. Methods: Finite element analysis was used to simulate 8 construct variations in a C7 vertebrectomy model with pedicle screw fixation in C5-T2. Variations included the material of rods (titanium or cobalt-chrome alloys), presence or absence of splint rods, the diameters of the splint rods (3.5 or 4.5 mm), and the size of lateral mass screws (3.5 mm or 4.0 mm). Boundary conditions replicated ASTM F1717/ISO 12189 standards. Yield load, displacement, stiffness, and stress distributions were analyzed under worst-case loading (2 cm displacement). Results: The best configuration was comprised of 3.5 mm titanium primary and splint rods, which achieved the highest load capacity of 107N and stiffness of 29.8 N/mm. The worst configuration was comprised of single 3.5 mm titanium rods, which demonstrated the lowest load capacity of 66N. Conclusions: Adding splint rods improves load bearing capacity of cervicothoracic fixation constructs. Increasing construct stiffness through increasing diameter of the rods or screws, or through change in rod alloy to cobalt chrome does not always result in an improvement of the load bearing capacity as it risks earlier failure at the bone-screw interface. Optimal construct design is a careful balance between construct stiffness and load-sharing.

28 September 2026 in Global Spine Journal
Verified
Journal Article
Open access
JSJaskaran Singh
Jaskaran Singh
MSMarion Sylvain
Marion Sylvain
MVMikko Vorster
Mikko Vorster
BBBona Baissa
Bona Baissa
AAAazad Abbas
Aazad Abbas
MGMichael Goytan
Michael Goytan
Study design: Systematic Review and Meta-Analysis. Objectives: Navigation-guided screw placement improves screw accuracy and may reduce hardware-related revision, yet its effect on overall unexpected return to the operating room (URTO) remains uncertain. This study compares image-guided (navigation and robotics) with freehand screw placement for hardware-related revision, non-hardware reoperation, and URTO following spinal fixation. Methods: A PRISMA-guided systematic review identified comparative studies evaluating image-guided versus freehand screw fixation. Two reviewers performed screening, data extraction, and risk-of-bias assessment. Odds ratios (ORs) were pooled using a random-effects Mantel-Haenszel meta-analysis. Subgroup analyses compared navigated, robotic, and freehand techniques. Results: Twenty-one studies were included, comprising 91,285 patients (8,743 image-guided; 82,442 freehand). Compared with freehand, image guidance was associated with lower odds of hardware-related revision (OR 0.55, 95% CI 0.40–0.75) and lower odds of URTO (OR 0.69, 95% CI 0.50–0.94), with no difference in non-hardware reoperation (OR 1.03, 95% CI 0.67–1.57). Navigation was associated with lower odds of hardware-related revision (OR 0.51, 95% CI 0.35–0.77) and URTO (OR 0.63, 95% CI 0.51–0.77) versus freehand, whereas robotics showed no significant differences across outcomes. Indirect comparison between navigation and robotics was not statistically significant. Risk of bias was overall high because of retrospective study design, confounding, and inconsistent outcome reporting. Conclusions: Navigation was associated with lower odds of hardware-related revision and lower odds of URTO, without a difference in non-hardware reoperation. Robotics showed no statistically significant advantage over freehand fixation, but its underrepresentation and differing case mix limit comparative conclusions.

22 December 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
SGSara Gustafson
Sara Gustafson
JSJaskaran Singh
Jaskaran Singh
MAMonther Abuhantash
Monther Abuhantash
TGTrevor Gascoyne
Trevor Gascoyne
MGMichael Goytan
Michael Goytan
Anterior cervical discectomy and fusion (ACDF) and cervical vertebrectomy with interbody fusion (CVIF) are commonly performed spine procedures that rely on anterior plate fixation for stability. This biomechanical study evaluated the effects of screw length, plate length, and posterior fixation augmentation on the stability of anterior cervical fixation constructs under worst-case conditions. Using osteopenic-grade polyurethane foam blocks, four construct configurations representing discectomy and corpectomy models were tested with varying anterior plate lengths (22 mm, 34 mm), screw lengths (14 mm, 16 mm), and the addition of posterior fixation. Static and fatigue testing were per-formed using methods adapted from ASTM F1717, with fatigue run-out defined at 1.2 million cycles to simulate the fusion period. Static testing demonstrated the lowest yield load in constructs using a short plate with shorter screws. Fatigue testing showed that increasing screw length from 14 to 16 mm increased maximum fatigue load by 1.6-fold, while the addition of posterior fixation increased fatigue capacity by 3.6-fold. Increasing plate length resulted in a modest reduction in fatigue performance. These findings indicate that posterior fixation provides the greatest improvement in construct fatigue resistance, while increased screw length offers a less invasive means of enhancing stability, informing surgical strategies for high-risk ACDF and CVIF cases.

7 October 2026 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
DBDaniel Bour
Daniel Bour
KWKevin Jieyi Wang
Kevin Jieyi Wang
GSGurjovan Sahi
Gurjovan Sahi
JSJaskaran Singh
Jaskaran Singh
NGNischal Ghimire
Nischal Ghimire
AAAazad Abbas
Aazad Abbas