8 October 2025 in Global Spine Journal
Verified
Journal Article
Open access
IPIan Polyzois
Ian Polyzois
JSJaskaran Singh
Jaskaran Singh
SGSara Gustafson
Sara Gustafson
TGTrevor Gascoyne
Trevor Gascoyne
MGMichael Goytan
Michael Goytan
Study Design: Basic Science Study. Objective: To determine the impact of splint rods, rod material, and rod diameter on cervicothoracic construct load bearing capacity. Methods: Finite element analysis was used to simulate 8 construct variations in a C7 vertebrectomy model with pedicle screw fixation in C5-T2. Variations included the material of rods (titanium or cobalt-chrome alloys), presence or absence of splint rods, the diameters of the splint rods (3.5 or 4.5 mm), and the size of lateral mass screws (3.5 mm or 4.0 mm). Boundary conditions replicated ASTM F1717/ISO 12189 standards. Yield load, displacement, stiffness, and stress distributions were analyzed under worst-case loading (2 cm displacement). Results: The best configuration was comprised of 3.5 mm titanium primary and splint rods, which achieved the highest load capacity of 107N and stiffness of 29.8 N/mm. The worst configuration was comprised of single 3.5 mm titanium rods, which demonstrated the lowest load capacity of 66N. Conclusions: Adding splint rods improves load bearing capacity of cervicothoracic fixation constructs. Increasing construct stiffness through increasing diameter of the rods or screws, or through change in rod alloy to cobalt chrome does not always result in an improvement of the load bearing capacity as it risks earlier failure at the bone-screw interface. Optimal construct design is a careful balance between construct stiffness and load-sharing.

22 December 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
SGSara Gustafson
Sara Gustafson
JSJaskaran Singh
Jaskaran Singh
MAMonther Abuhantash
Monther Abuhantash
TGTrevor Gascoyne
Trevor Gascoyne
MGMichael Goytan
Michael Goytan
Anterior cervical discectomy and fusion (ACDF) and cervical vertebrectomy with interbody fusion (CVIF) are commonly performed spine procedures that rely on anterior plate fixation for stability. This biomechanical study evaluated the effects of screw length, plate length, and posterior fixation augmentation on the stability of anterior cervical fixation constructs under worst-case conditions. Using osteopenic-grade polyurethane foam blocks, four construct configurations representing discectomy and corpectomy models were tested with varying anterior plate lengths (22 mm, 34 mm), screw lengths (14 mm, 16 mm), and the addition of posterior fixation. Static and fatigue testing were per-formed using methods adapted from ASTM F1717, with fatigue run-out defined at 1.2 million cycles to simulate the fusion period. Static testing demonstrated the lowest yield load in constructs using a short plate with shorter screws. Fatigue testing showed that increasing screw length from 14 to 16 mm increased maximum fatigue load by 1.6-fold, while the addition of posterior fixation increased fatigue capacity by 3.6-fold. Increasing plate length resulted in a modest reduction in fatigue performance. These findings indicate that posterior fixation provides the greatest improvement in construct fatigue resistance, while increased screw length offers a less invasive means of enhancing stability, informing surgical strategies for high-risk ACDF and CVIF cases.

24 July 2026 in Journal of Craniovertebral Junction and Spine
Verified
Journal Article
Open access
IPIan Polyzois
Ian Polyzois
JSJaskaran Singh
Jaskaran Singh
SGSara Gustafson
Sara Gustafson
TGTrevor Gascoyne
Trevor Gascoyne
FNFranck Le Navéaux
Franck Le Navéaux
MGMichael Goytan
Michael Goytan
Study Design: This was a basic science study. Objective: The objective of this study was to determine which occipital–cervical (OC) fixation construct best balances construct stiffness with minimization of occipital screw pullout forces. Materials and Methods: Finite element analysis was used to simulate seven OC construct variations spanning across C1 with fixation in C2 and C3. Variations included the use of occiput rods, keel plates with varying width, two-hole clamps, two-hole clamps in addition to medial or lateral one-hole clamps, and occiput screw diameter. Modeling was in accordance with ASTM F2706/ISO 12189 guidelines. Materials were in accordance with ASTM F1295/ASTM F1839/ISO 10243 guidelines. Outcomes included bending stiffness, axial screw pullout reaction forces, and von Mises stress distribution to identify stress localization and predicted failure modes. Constructs were ranked using multiattribute utility theory (MAUT). Results: Construct E (comprised two-hole clamps with added one-hole medial clamps) demonstrated the highest bending stiffness (820 N.mm/deg) and the highest MAUT utility score (0.79), representing the optimal balance of stiffness and minimized screw pullout forces. Construct F (comprised two-hole clamps alone) demonstrated the lowest bending stiffness (509 N.mm/deg). Conclusions: A construct composed of medially fixed one-hole and two-hole clamps provided the best balance of bending stiffness and minimized occipital screw pullout reaction forces. Aligning screws near the median plane, using bilateral clamp fixation, and avoiding components that mechanically join the two rods improved construct performance. Increasing occipital screw diameter from 4.5 mm to 5.0 mm had little biomechanical impact. Stress localization at occipital component–rod interfaces suggests a potential weak point with risk of notching and fatigue failure.

17 June 2025 in Clinical Spine Surgery
Verified
Journal Article
Closed access
MAMonther Abuhantash
Monther Abuhantash
DMDrew Md Mulhall
Drew Md Mulhall
SGSara Msc Gustafson
Sara Msc Gustafson
MGMichael Goytan
Michael Goytan
Study Design: Biomechanical study. Objective: Determine the effect of screw thread pitch, trajectory, and purchase depth on the screw pull-out strength in lateral mass fixation constructs. Summary of Background Data: Fusion of the cervical spine is routinely performed with lateral mass screw fixation. It is imperative to optimize the lateral mass fixation construct strength to minimize the risk of hardware failure and subsequent complications and reoperations. Methods: Biomechanical testing was performed using bicortical artificial bone models to replicate the lateral mass of the cervical spine. Cortical and cancellous screws of 3.5 mm diameter were compared at 3 purchase depths: unicortical, bicortical, and bicortical backed-out to unicortical, and 2 trajectories: Roy-Camille (RC) and Magerl. In a second construct, bicortical 3.5 mm screws were replaced with unicortical 4.0 mm screws. Both thread pitches and trajectories were also compared. Results: Fixation with the RC technique was stronger than with Magerl in all constructs. Roy-Camille fixation using cortical screws was stronger than cancellous screws in all purchase depths. Magerl fixation using cancellous screws was stronger in all purchase depths but only statistically significant for the group where the bicortical screw was backed-out to unicortical. The construct where the bicortical 3.5 mm screw was replaced with a 4.0 mm unicortical screw was stronger than when the screw was backed-out to a unicortical depth. This was significant for cortical screws in both trajectories but only significant for cancellous screws using the RC technique. Conclusions: Biomechanical strength of cervical lateral mass fixation was shown to be directly influenced by thread pitch, depth, and trajectory. Thus, spine surgeons should be cognizant of their fixation constructs and any changes made to their components.