Trevor Gascoyne

Mr. Trevor Gascoyne


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2019 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
TGTrevor Gascoyne
Trevor Gascoyne
BFBryan Flynn
Bryan Flynn
TTThomas Turgeon
Thomas Turgeon
CBColin Burnell
Colin Burnell
Several hydroxyapatite (HA)-coated femoral stems from a single manufacturer were identified to have aseptically loosened at mid-term follow-up despite prior radiographic appearance of osseointegration. Possible causes and associated risk factors for stem loosening were explored through radiographic review and implant retrieval analysis. Forty-six retrieved hip stems (Corail, DePuy-Synthes) were identified and grouped by bearing type: metal-on-metal (MoM), metal-on-polyethylene, and ceramic-on-ceramic. Stem lucency was graded on post-operative radiographs up to the time of revision. Stems were examined for stripping of the HA coating, taper corrosion, and bearing wear in metal-on-metal cases. Patient demographics, implant design features, and perioperative data were collected from electronic databases and patient charts. Aseptic loosening occurred in 37% of cases examined. MoM bearings were associated with 7.25 times greater risk of loosening compared to other bearing types. Stem radiolucency was more prevalent for MoM cases and, although not statistically significant, demonstrated progressive lucency. Taper corrosion appeared more severe for MoM cases and correlated with proximal stem radiolucency. Removal of the HA coating from the stems was associated with both taper corrosion and MoM bearing wear. Length of implantation was a confounding factor for the MoM cases. This study has demonstrated a high risk of mid-term loosening of previously osseointegrated HA-coated femoral stems when paired with a MoM bearing. The mechanism of loosening appears progressive in nature and related to the MoM bearing, possibly interacting with the HA coating. If such loosening is recognized early, rapid revision may allow for retention of the femoral stem.

22 December 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
SGSara Gustafson
Sara Gustafson
JSJaskaran Singh
Jaskaran Singh
MAMonther Abuhantash
Monther Abuhantash
TGTrevor Gascoyne
Trevor Gascoyne
MGMichael Goytan
Michael Goytan
Anterior cervical discectomy and fusion (ACDF) and cervical vertebrectomy with interbody fusion (CVIF) are commonly performed spine procedures that rely on anterior plate fixation for stability. This biomechanical study evaluated the effects of screw length, plate length, and posterior fixation augmentation on the stability of anterior cervical fixation constructs under worst-case conditions. Using osteopenic-grade polyurethane foam blocks, four construct configurations representing discectomy and corpectomy models were tested with varying anterior plate lengths (22 mm, 34 mm), screw lengths (14 mm, 16 mm), and the addition of posterior fixation. Static and fatigue testing were per-formed using methods adapted from ASTM F1717, with fatigue run-out defined at 1.2 million cycles to simulate the fusion period. Static testing demonstrated the lowest yield load in constructs using a short plate with shorter screws. Fatigue testing showed that increasing screw length from 14 to 16 mm increased maximum fatigue load by 1.6-fold, while the addition of posterior fixation increased fatigue capacity by 3.6-fold. Increasing plate length resulted in a modest reduction in fatigue performance. These findings indicate that posterior fixation provides the greatest improvement in construct fatigue resistance, while increased screw length offers a less invasive means of enhancing stability, informing surgical strategies for high-risk ACDF and CVIF cases.