Erik Dorthe

Mr. Erik Dorthe

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2016 in Tissue Engineering Part A
Verified
Journal Article
Closed access
KKKarl Erich Kador
Karl Erich Kador
SGShawn Patrick Grogan
Shawn Patrick Grogan
EDErik Dorthe
Erik Dorthe
PVPraseeda Venugopalan
Praseeda Venugopalan
MMMonisha Malek
Monisha Malek
DDDarryl D'lima
Darryl D'lima
Retinal ganglion cells (RGC) are responsible for the transfer of signals from the retina to the brain. As part of the central nervous system, RGCs are unable to regenerate following injury and implanted cells have limited capacity to orient and integrate in vivo. During development, secreted guidance molecules along with signals from extracellular matrix and the vasculature guide cell positioning for example around the fovea, and axon outgrowth; however, these changes are temporally regulated and are not the same in the adult. Here, we combine electrospun cell transplantation scaffolds capable of RGC neurite guidance with thermal inkjet 3D cell printing techniques capable of precise positioning of RGCs on the scaffold surface. Optimal printing parameters are developed for viability, electrophysiological function and neurite pathfinding. Different media, commonly used to promote RGC survival and growth, were tested under varying conditions. When printed in growth media containing both brain-derived neurotrophic factor (BDNF) and ciliary neurotrophic factor (CNTF), RGCs maintained survival and normal electrophysiological function, and displayed radial axon outgrowth when printed onto electrospun scaffolds. These results demonstrate that 3D printing technology may be combined with complex electrospun surfaces in the design of future retinal models or therapies.

17 February 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
THTakehito Hananouchi
Takehito Hananouchi
YCYanjun Chen
Yanjun Chen
SJSAEED JERBAN
SAEED JERBAN
MTMasaru Teramoto
Masaru Teramoto
YMYajun Ma
Yajun Ma
DDDarryl D'lima
Darryl D'lima
In this study, we combined quantitative ultrashort echo time (UTE) magnetic resonance (MR) imaging and an investigation by a probing device with tri-axial force sensor to seek correlations with mechanical properties of human patellar cartilage for in situ evaluation of biomechanical properties. Cartilage blocks (15 × 20 × 5 mm3) were dissected from the patella of six donors; 5 mm square regions of interest from the cartilage blocks were imaged using UTE-MR imaging sequences (T2* and magnetization transfer ratio (MTR)), and mechanical properties were measured using a micro indentation device. Then, the vertical reaction force on the cartilage surface was measured while push-probing forward 3 mm with the probing device at a 30° tilt to the horizontal plane. The results showed a positive correlation between stiffness/elastic modulus and each predictor variable (UTE-T2* (r = 0.240 and 0.255, respectively, UTE-MTR (r = 0.378 and 0.379, respectively), and probing device force (r = 0.426 and 0.423, respectively). Furthermore, multiple linear regression analysis showed the combination of the three predictors had stronger correlation (adjusted r2 = 0.314 (stiffness), 0.323 (elastic), respectively). Our results demonstrate the potential for these non- and less- invasive methods for in situ evaluation of the mechanical properties of cartilage tissue.

7 September 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
THTakehito Hananouchi
Takehito Hananouchi
SSShinji Satake
Shinji Satake
KSKei Sakao
Kei Sakao
HKHiroshi Katsuda
Hiroshi Katsuda
NSNagakazu Shimada
Nagakazu Shimada
DDDarryl D'lima
Darryl D'lima
To determine whether the mechanical properties of joint soft tissues such as cartilage can be calculated from quantitative magnetic resonance imaging (MRI) data, we investigated whether the mechanical properties of articular cartilage and meniscus scheduled to be resected during arthroplasty are correlated with the T2 relaxation time on quantitative MRI at the same location. Six patients who had undergone knee arthroplasty and seven who had undergone hip arthroplasty were examined. For the knee joint, the articular cartilage and lateral meniscus of the distal lateral condyle of the femur and proximal lateral tibia were examined, while for the hip joint, the articular cartilage above the femoral head was studied. We investigated the relationship between T2 relaxation time by quantitative MRI and stiffness using a hand-made compression tester at 235 locations. The patient-individualized template technique was used to align the two measurement sites. The results showed a negative correlation (from −0.30 to −0.35) in the less severely damaged articular cartilage and meniscus. This indicates that tissue mechanical properties can be calculated from T2 relaxation time, suggesting that quantitative MRI is useful in determining when to start loading after interventional surgery on cartilage tissue and in managing the health of elderly patients.

23 December 2021 in Bioengineering
Verified
Journal Article
Open access
PDF file
THTakehito Hananouchi
Takehito Hananouchi
TSTomoyuki Suzuki
Tomoyuki Suzuki
EDErik Dorthe
Erik Dorthe
Jiang DuJiang Du
Jiang Du
DDDarryl D'lima
Darryl D'lima
There are various methods for reconstructing the anterior cruciate ligament (ACL) from other muscles or tendons. Initial tension of the reconstructed ACL is one of the key elements affecting postoperative outcomes. However, tension cannot be measured after graft fixation. The only intraoperative assessment is pull probing, which is performed by pulling joint soft tissues with the arthroscopic probe and can be measured quantitatively. Therefore, its value might be used as an alternative value for the mechanical property of the ACL. Using a probing device one author developed to measure the resistance force of soft tissues quantitatively while probing, we measured the resistance force of dissected ACLs and used tensile testing to investigate the correlation between the resistance force and the mechanical property of the ligaments. According to the results, when a certain amount of tension (strain; 16.6%) was applied, its mechanical properties were moderately correlated (r = 0.56 [p = 0.045]) with the probing force. Therefore, the tension of the reconstructed ACL after fixation under real ACL reconstruction surgery can be derived from the value of the probing device.