Abdel Naser Daoud

Dr. Abdel Naser Daoud


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2024 in Buildings
Verified
Journal Article
Open access
PDF file
AAabdalla alrashdan
abdalla alrashdan
AGAtef Ghaleb
Atef Ghaleb
KAKhalid Haj Ahmad
Khalid Haj Ahmad
ADAbdel Naser Daoud
Abdel Naser Daoud
This experimental study explores the integration of Phase Change Materials (PCMs) within building envelopes. The research specifically centers on the utilization of two microencapsulated paraffin-based PCMs with melting points of 37 °C and 43 °C. The study assesses their performance within cement and gypsum-based PCM composites, concentrating on service areas often overlooked in thermal analysis, including underground garages, staircases, and utility rooms. The experimental setup included constructing three chambers inside an underground garage during the hot months of June and July in Saudi Arabia. Two chambers were assigned to integrate the PCM, while the third chamber served as a control without PCM. The experiment unfolds in two phases. In the initial phase, the objective was to determine which PCM is more effective in reducing the heat load inside the chambers. This led to the adoption of the 43 °C PCM for the subsequent stage. The adoption of the 43 °C PCM resulted in a fourfold decrease in heat compared to the 37 °C PCM. The second phase investigates the integration of the selected PCM with cement and gypsum composites. The percentage of PCM incorporated into the concrete and gypsum composites was determined experimentally. For cement-based composites, the identified percentage that maintains material integrity is 20%, and for gypsum-based composites, it is 22%. The findings demonstrate a significant reduction in cooling load with PCM incorporation, with cement-based composites exhibiting superior thermal performance compared to gypsum-based alternatives and reducing the heat load by approximately 63%. Additionally, it was observed that concrete reduced the highest temperature during the day by 5.2 °C, which equates to about a 10% reduction, further enhancing comfort. Conducted over the course of two summer seasons, this study contributes valuable insights toward improving the quality of life for building occupants, considering various factors such as their living environment.

5 January 2026 in Micromachines
Verified
Journal Article
Open access
PDF file
ADAbdel Naser Daoud
Abdel Naser Daoud
AGAtef Ghaleb
Atef Ghaleb
ZAZulfiqur Ali
Zulfiqur Ali
AHAli Abdelhafeez Hassan
Ali Abdelhafeez Hassan
In the microinjection molding process, continuous monitoring is important for optimization of the process and control. In microfluidic or lab-on-chip devices, defective microfeatures can compromise biological assays and diagnostic results, and therefore, the quality of these features is a critical issue. Microfeatures can be inspected using advanced inspection and microscopic techniques, but these are expensive, time-consuming, and difficult to use for full-scale production. We present here a new technique for quality control of microfeatures, which uses the filling of a controlled microcavity inside or outside the molded part as a quality control tool for filling microfeatures. Micro gaps (checkpoints) are used as an indicator of microfeature filling. Two micro gaps can be used for filling (checkpoints) as a Go/No-Go gauge.

31 July 2026 in Methods and Protocols
Verified
Journal Article
Open access
PDF file
MZMahmoud Zhra
Mahmoud Zhra
RARawan Awni Alarawi
Rawan Awni Alarawi
SMShaimaa Mohamed
Shaimaa Mohamed
ADAbdel Naser Daoud
Abdel Naser Daoud
HFHana Fakhoury
Hana Fakhoury
AAAhmad Samir Aljada
Ahmad Samir Aljada
Column-based RNA extraction is time-consuming, involves cumulative losses during transfer, wash, and elution steps, and has reduced recovery from sub-microliter inputs. These limitations restrict gene-expression analysis in small cell populations and low-titre pathogen detection in clinical specimens. We developed the Direct Cell-to-PCR Lysis Buffer, a defined non-ionic detergent formulation containing Tween 20 (0.3%), Triton X-100 (0.1%), and NP-40 (0.1%), for RNA-extraction-free one-step RT-qPCR. Lysates are added directly to reactions without pretreatment, heating, or column purification. Non-ionic detergents produced Ct values comparable to detergent-free controls, whereas SDS, Sarkosyl, and sodium deoxycholate abolished amplification. The method was benchmarked against the standard column-based PureLink RNA Mini Kit using SaOS-2 cells, MCF7 cells, peripheral blood mononuclear cells, and nasal and throat swabs. Direct lysates showed Ct offsets of 0.6 to 2.85 cycles compared with purified RNA, depending on sample type. Ubiquitin-C mRNA was detected down to a single-cell-equivalent input, and plasmid templates were detected to approximately 100 copies per reaction. The buffer was compatible with multiplex ScriptTaq COVID PCR, with unchanged RdRP, N, and RPP30 Ct values, and tolerated sodium azide up to 0.1%, supporting rapid direct RT-qPCR workflows.