Edward J McPherson

Dr. Edward J McPherson


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2019 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
SYSteven Yang
Steven Yang
MDMatthew V. Dipane
Matthew V. Dipane
CLConrad H. Lu
Conrad H. Lu
TSThomas P. Schmalzried
Thomas P. Schmalzried
EMEdward J McPherson
Edward J McPherson
Background: The utilization of lymphocyte transformation testing (LTT) has increased for diagnosing metal sensitivity associated with total knee arthroplasty (TKA), but its validity for the diagnosis of TKA failure due to an immune reaction has not been established. In this study, we sought to characterize the relationship of a positive LTT result to histopathologic findings and clinical and functional outcomes. Methods: This was a retrospective study of 27 well-fixed, aseptic, primary TKA cases in which the patient had persistent pain and/or stiffness and underwent revision due to a suspected metal allergy to nickel, as determined on the basis of positive LTT. Revision procedures were performed by a single experienced arthroplasty surgeon. Periprosthetic tissue samples obtained at the time of revision surgery were scored using the aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) scoring system. Results: Eight patients were categorized as mildly reactive; 8 patients, moderately reactive; and 11 patients, highly reactive to nickel by LTT. The predominant findings on routine histopathologic analysis were fibrosis and varying degrees of lymphocytic infiltration in 17 (63%) of the 27 cases. The average ALVAL score of the cohort was 3.1 ± 1.9, of a maximum score of 10. Average Knee Society Score (KSS) values improved post-revision, as did range of motion (all p < 0.01). Neither LTT stimulation index as a continuous variable nor as a categorical variable (mildly reactive, moderately reactive, highly reactive) was correlated with ALVAL score, pre-revision function (as assessed by KSS-clinical, KSS-functional, and range of motion), or change in function at the most recent follow-up (0.015 < r < 0.30, 0.13 < p < 0.95). In addition, the ALVAL score did not correlate significantly with either pre-revision or post-revision KSS or range of motion (0.061 < r < 0.365, 0.09 < p < 0.88). Conclusions: On the basis of this analysis, including histopathologic assessment, LTT results alone were insufficient for the diagnosis of TKA failure due to an immune reaction. A positive LTT may not indicate that an immune reaction is the cause of pain and stiffness post-TKA. The role of LTT in assessing TKA failure from an immune reaction needs further investigation. Diagnostic criteria for such TKA failure need to be established. Level of Evidence: Diagnostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

1 May 2022 in The Bone & Joint Journal
Verified
Journal Article
Open access
CHChristopher David Hamad
Christopher David Hamad
MCMadhav Chowdhry
Madhav Chowdhry
DSDevin Sindeldecker
Devin Sindeldecker
NBNicholas M. Bernthal
Nicholas M. Bernthal
PSPaul Stoodley
Paul Stoodley
EMEdward J McPherson
Edward J McPherson
Periprosthetic joint infection (PJI) is a difficult complication requiring a comprehensive eradication protocol. Cure rates have essentially stalled in the last two decades, using methods of antimicrobial cement joint spacers and parenteral antimicrobial agents. Functional spacers with higher-dose antimicrobial-loaded cement and antimicrobial-loaded calcium sulphate beads have emphasized local antimicrobial delivery on the premise that high-dose local antimicrobial delivery will enhance eradication. However, with increasing antimicrobial pressures, microbiota have responded with adaptive mechanisms beyond traditional antimicrobial resistance genes. In this review we describe adaptive resistance mechanisms that are relevant to the treatment of PJI. Some mechanisms are well known, but others are new. The objective of this review is to inform clinicians of the known adaptive resistance mechanisms of microbes relevant to PJI. We also discuss the implications of these adaptive mechanisms in the future treatment of PJI. Cite this article: Bone Joint J 2022;104-B(5):575–580.

1 October 2002 in Scottish Medical Journal
Verified
Journal Article
Closed access
PDF file
EMEdward J McPherson
Edward J McPherson
RDR. A. Dunsmuir
R. A. Dunsmuir
We performed a retrospective review of hyponatraemia in patients with hip fractures, before and after surgery. All patients admitted with fractures of the neck of femur who had a surgical intervention to deal with the fracture were included. Results were determined using two definitions for hyponatraemia. The incidence of preoperative and post-operative hyponatraemia were both 2.8% if hyponatraemia was defined as [Na]<130mmol/l. No cases of hyponatraemia were found pre-operatively when hyponatraemia was defined as [Na]<125mmol/l. Using this definition the post operative incidence of hyponatraemia was 0.93%. The incidence of hyponatraemia in this group of patients is small. However the potentially severe affects of hyponatraemia warrant close monitoring of these patients and the establishment of methods to prevent this problem from occurring.

8 March 2021 in Antibiotics
Verified
Journal Article
Open access
PDF file
KMKelly Moore
Kelly Moore
RORebecca Wilson-Van Os
Rebecca Wilson-Van Os
DDDevendra Dusane
Devendra Dusane
JBJacob Brooks
Jacob Brooks
CDCraig Delury
Craig Delury
PSPaul Stoodley
Paul Stoodley
Antibiotic-tolerant bacterial biofilms are notorious in causing PJI. Antibiotic loaded calcium sulfate bead (CSB) bone void fillers and PMMA cement and powdered vancomycin (VP) have been used to achieve high local antibiotic concentrations; however, the effect of drainage on concentration is poorly understood. We designed an in vitro flow reactor which provides post-surgical drainage rates after knee revision surgery to determine antibiotic concentration profiles. Tobramycin and vancomycin concentrations were determined using LCMS, zones of inhibition confirmed potency and the area under the concentration–time curve (AUC) at various time points was used to compare applications. Concentrations of antibiotcs from the PMMA and CSB initially increased then decreased before increasing after 2 to 3 h, correlating with decreased drainage, demonstrating that concentration was controlled by both release and flow rates. VP achieved the greatest AUC after 2 h, but rapidly dropped below inhibitory levels. CSB combined with PMMA achieved the greatest AUC after 2 h. The combination of PMMA and CSB may present an effective combination for killing biofilm bacteria; however, cytotoxicity and appropriate antibiotic stewardship should be considered. The model may be useful in comparing antibiotic concentration profiles when varying fluid exchange is important. However, further studies are required to assess its utility for predicting clinical efficacy.

19 June 2025 in Journal of Bone and Joint Surgery
Verified
Journal Article
Open access
CHChristopher David Hamad
Christopher David Hamad
WSWilliam L. Sheppard
William L. Sheppard
RCRene Chun
Rene Chun
ZMZara Mamouei
Zara Mamouei
TLTrevor S. Lloyd
Trevor S. Lloyd
EMEdward J McPherson
Edward J McPherson
Background: Implant-associated infections (IAIs) require aggressive debridement to eliminate microbial bioburden. The use of irrigants may improve microbial killing during debridement. This study compared the efficacy of surgical irrigants in vitro against Staphylococcus aureus alone and in combination with Candida albicans, in both planktonic and biofilm states. Methods: Full-strength Dakin’s solution, 0.35% povidone-iodine (PI), 10% PI, 3% hydrogen peroxide (HP), a 1:1 combination of 10% PI and 3% HP (PI + HP), Irrisept, XPERIENCE, Bactisure, and normal saline solution were tested. For planktonic testing, 1 × 106 colony-forming units (CFUs) of S. aureus and C. albicans were utilized, and biofilms were grown in these conditions on 0.8 × 10-mm titanium alloy Kirschner wires for 48 hours. Killing assays were performed using 5-minute dwell times. Success was defined by complete eradication of planktonic or biofilm CFUs. Results: PI + HP and Bactisure were the only irrigants to eradicate S. aureus in both planktonic and biofilm states. PI + HP was the only irrigant to eradicate polymicrobial S. aureus + C. albicans bioburden in both states. Conclusions: PI + HP and Bactisure were superior irrigants against S. aureus, eliminating it in planktonic and biofilm states. PI + HP was the only irrigant to eradicate polymicrobial S. aureus + C. albicans bioburden in both states. In vivo studies are needed to evaluate the clinical effectiveness. Clinical Relevance: Surgical irrigants have variable efficacy in eradicating microbes depending on their state of existence (planktonic versus biofilm). In this study, the most effective eradication of polymicrobial S. aureus + C. albicans bioburden was a 1:1 combination of 10% PI and 3% HP, which is of nominal cost.

1 December 2022 in Bone & Joint Open
Verified
Journal Article
Open access
EMEdward J McPherson
Edward J McPherson
ASAlexandra I. Stavrakis
Alexandra I. Stavrakis
MCMadhav Chowdhry
Madhav Chowdhry
NCNora L. Curtin
Nora L. Curtin
MDMatthew V. Dipane
Matthew V. Dipane
BCBrooke M. Crawford
Brooke M. Crawford
Aims: Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with bone graft materials for restoration. Autograft is restricted due to limited volume, and allogenic grafts have downsides including cost, availability, and operative processing. Bone graft substitutes (BGS) are an attractive alternative if they can demonstrate positive remodelling. One potential product is a biphasic injectable mixture (Cerament) that combines a fast-resorbing material (calcium sulphate) with the highly osteoconductive material hydroxyapatite. This study reviews the application of this biomaterial in large acetabular defects. Methods: We performed a retrospective review at a single institution of patients undergoing revision THA by a single surgeon. We identified 49 consecutive patients with large acetabular defects where the biphasic BGS was applied, with no other products added to the BGS. After placement of metallic acetabular implants, the BGS was injected into the remaining bone defects surrounding the new implants. Patients were followed and monitored for functional outcome scores, implant fixation, radiological graft site remodelling, and revision failures. Results: Mean follow-up was 39.5 months (36 to 71), with a significant improvement in post-revision function compared to preoperative function. Graft site remodelling was rated radiologically as moderate in 31 hips (63%) and strong in 12 hips (24%). There were no cases of complete graft site dissolution. No acetabular loosening was identified. None of the patients developed clinically significant heterotopic ossification. There were twelve reoperations: six patients developed post-revision infections, three experienced dislocations, two sustained periprosthetic femur fractures, and one subject had femoral component aseptic loosening. Conclusion: Our series reports bone defect restoration with the sole use of a biphasic injectable BGS in the periacetabular region. We did not observe significant graft dissolution. We emphasize that successful graft site remodelling requires meticulous recipient site preparation. Cite this article: Bone Jt Open 2022;3(12):991–997.