Introduction: Local antimicrobial delivery via calcium sulfate (CaSO4) beads is used as an adjunctive treatment for periprosthetic joint infection. There is limited clinical information describing the performance of antimicrobial-loaded CaSO4 (ALCS) in large-scale applications. We developed a simulated large joint model to study properties of eluting ALCS. Methods: The in vitro testing platform was an adapted standardized model for tribological testing of prosthetic total hips and total knees (ASTM F732). The model was 70 mL total fluid volume, 25 % bovine serum, and 75 % phosphate-buffered saline, using ISO standard 14242-1 for human synovial fluid simulation. Four brands of CaSO4 were evaluated. Each 10 mL of CaSO4 was loaded with 1.2 grams (g) of tobramycin and 1 g of vancomycin powders. A 35 mL bead volume, equaling 175 beads, of each product was placed in incubated flasks. The test period was 6 weeks with scheduled interval fluid exchanges. Fluid samples were tested for antibiotic and calcium concentrations and pH. Results: Antibiotic elution showed an initial burst on Day 1, followed by a logarithmic reduction over 1 week. Tobramycin fully eluted within 2.5 weeks. Vancomycin showed sustained release over 6 weeks. Calcium ion concentrations were high, with gradual decrease after 3 weeks. All four CaSO4 products were inherently acidic. Fluid became more acidic with the addition of antibiotics primarily driven by vancomycin. Discussion: Clinicians should be cognizant of tobramycin elution burst with ALCS in large loads. The main driver of acidic pH levels was vancomycin. We propose that joint complications may result from lowered fluid acidity, and we suggest clinical study of synovial pH.
Aims: Large acetabular bone defects encountered in revision total hip arthroplasty (THA) are challenging to restore. Metal constructs for structural support are combined with bone graft materials for restoration. Autograft is restricted due to limited volume, and allogenic grafts have downsides including cost, availability, and operative processing. Bone graft substitutes (BGS) are an attractive alternative if they can demonstrate positive remodelling. One potential product is a biphasic injectable mixture (Cerament) that combines a fast-resorbing material (calcium sulphate) with the highly osteoconductive material hydroxyapatite. This study reviews the application of this biomaterial in large acetabular defects. Methods: We performed a retrospective review at a single institution of patients undergoing revision THA by a single surgeon. We identified 49 consecutive patients with large acetabular defects where the biphasic BGS was applied, with no other products added to the BGS. After placement of metallic acetabular implants, the BGS was injected into the remaining bone defects surrounding the new implants. Patients were followed and monitored for functional outcome scores, implant fixation, radiological graft site remodelling, and revision failures. Results: Mean follow-up was 39.5 months (36 to 71), with a significant improvement in post-revision function compared to preoperative function. Graft site remodelling was rated radiologically as moderate in 31 hips (63%) and strong in 12 hips (24%). There were no cases of complete graft site dissolution. No acetabular loosening was identified. None of the patients developed clinically significant heterotopic ossification. There were twelve reoperations: six patients developed post-revision infections, three experienced dislocations, two sustained periprosthetic femur fractures, and one subject had femoral component aseptic loosening. Conclusion: Our series reports bone defect restoration with the sole use of a biphasic injectable BGS in the periacetabular region. We did not observe significant graft dissolution. We emphasize that successful graft site remodelling requires meticulous recipient site preparation. Cite this article: Bone Jt Open 2022;3(12):991–997.
10 November 2021 in Journal of Bone and Joint Infection
Chronic periprosthetic joint infection (PJI) is a devastating complication that requires an aggressive eradication protocol. Local antimicrobial delivery via dissolvable calcium sulfate (CaSO4) using small-sized beads (3–8 mm) has been utilized as an adjunctive treatment combined with implant exchange, radical debridement, and antimicrobial loaded acrylic spacers. The non-exothermic setting of CaSO4 theoretically allows for any antimicrobial agent to be used, so long as mixing methods provide a consistent fabrication within a reasonable set time. This study performed the first in vitro mixing study, in which various antimicrobial agents, used singularly and in combination, were mixed with a synthetic CaSO4 product to observe and document their interactions. The study was performed in a simulated operating room environment. We report a standard mix formula with set times, testing 22 different antimicrobial agents, combinations, and doses. For some antimicrobials and combinations, set times using the standard formula were either too fast or exceedingly slow. For these 14 antimicrobial agents and combinations, we were able to arrive at individualized mixing methods. We present all mixing formulas and set times. In all, we were able to establish mixing methods that incorporate all antimicrobial agents and combinations that we have seen utilized via surgeon-directed use.
Periprosthetic joint infection (PJI) is a devastating complication of joint arthroplasty. In chronic PJI, a biofilm envelops the surface of implants, which contains microbiota within an extra-microbial polymeric matrix (EMPM). Microbial identification is paramount for effective treatment. In this study, we use a multi-modal, EMPM disrupting, neoadjuvant irrigant and compare the microbiota detected pre-lavage to post-lavage by two techniques: culture and Next Generation Sequencing (NGS). We suspect more organisms to be identified after applying an EMPM disrupting irrigant. A multicenter, prospective study was conducted on 38 patients with known Total Knee Arthroplasty PJI. At initial arthrotomy, synovial fluid was obtained and analyzed for quantitative cultures and microbial NGS. Joint was then irrigated with Bactisure Lavage followed by Normal Saline. Post-lavage samples were similarly obtained and analyzed. In pre-lavage samples for cultures, 55.3% of samples were positive, identifying 11 unique organisms. In post-lavage samples for cultures, 13.2% of samples were positive, identifying 5 unique organisms. In pre-lavage samples for NGS, 79% were DNA signal positive, identifying 126 unique organisms. In post-lavage samples for NGS, 74% of samples were DNA signal positive, identifying 177 unique organisms. Moreover, 135/177 of these organisms were not identified pre-lavage. In this pre-to-post irrigant study, culture showed a decrease in the number of identifiable organisms post-lavage. In contrast NGS revealed an increase in the number of identifiable organisms post-lavage. Furthermore, NGS identified 135 additional organisms, not detected pre-lavage. This suggests an increased diversity of microbes may exist within EMPM, which are not cultivable.
Infection rates in revision total hip arthroplasty are lower when antibiotic loaded cemented stems are utilized. Inspired by this technique, a point-of-care coating of antibiotic-loaded calcium sulfate (CaSO4) was applied to cementless revision stems in aseptic revision and 2nd stage reimplantation total hip arthroplasty. One hundred eleven consecutive femoral stems were coated. Just prior to insertion, 10 cc of CaSO4 was mixed with 1 g vancomycin and 240 mg tobramycin with the paste applied to the stem. The results were compared to a matched cohort (N = 104) performed across the previous 5 years. The surgical methods were comparable, but for the stem coating. The study group was followed for a minimum of 3 years. In the study cohort of 111 patients, there were 69 aseptic revisions with one periprosthetic joint infection (PJI) (1.4%) and 42 second-stage reimplantations with 2 PJIs (4.8%). In the control cohort of 104 patients, there were 74 aseptic revisions with one PJI (1.4%) and 30 second-stage reimplantations with 7 PJIs (23.3%). There was no significant reduction in PJI rate in the aseptic revision subgroup (1.4% study vs 1.4% control group), P = 1.000. Antibiotic stem coating reduced PJI rate in the 2nd stage reimplantation subgroup (23.3% control vs 4.8% study group), P = .028. In both groups, there were no cases of aseptic stem loosening. Point-of-care antibiotic coating of cementless revision femoral stems reduces PJI infection rate in 2nd stage reimplantations only. We theorize that microbes persist in the endosteal cortices after resection and may contribute to infection recurrence.