Javier García-Bella

Dr. Javier García-Bella

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2015 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
JCJesus Carballo-Alvarez
Jesus Carballo-Alvarez
JVJose M Vazquez-Molini
Jose M Vazquez-Molini
JSJuan C Sanz-Fernandez
Juan C Sanz-Fernandez
JGJavier García-Bella
Javier García-Bella
VPVicente Polo
Vicente Polo
Jose M Martinez de la CasaJose M Martinez de la Casa
Jose M Martinez de la Casa
In recent years new models of intraocular lenses are appearing on the market to reduce requirements for additional optical correction. The purpose of this study is to assess visual outcomes following bilateral cataract surgery and the implant of a FineVision® trifocal intraocular lens (IOL). Prospective, nonrandomized, observational study. Vision was assessed in 44 eyes of 22 patients (mean age 68.4 ± 5.5 years) before and 3 months after surgery. Aberrations were determined using the Topcon KR-1 W wave-front analyzer. LogMAR visual acuity was measured at distance (corrected distance visual acuity, CDVA 4 m), intermediate (distance corrected intermediate visual acuity, DCIVA 60 cm) and near (distance corrected near visual acuity, DCNVA 40 cm). The Pelli-Robson letter chart and the CSV-1000 test were used to estimate contrast sensitivity (CS). Defocus curve testing was performed in photopic and mesopic conditions. Adverse photic phenomena were assessed using the Halo v1.0 program. Mean aberration values for a mesopic pupil diameter were: total HOA RMS: 0.41 ± 0.30 μm, coma: 0.32 ± 0.22 μm and spherical aberration: 0.21 ± 0.20 μm. Binocular logMAR measurements were: CDVA −0.05 ± 0.05, DCIVA 0.15 ± 0.10, and DCNVA 0.06 ± 0.10. Mean Pelli-Robson CS was 1.40 ± 0.14 log units. Mean CSV100 CS for the 4 frequencies examined (A: 3 cycles/degree (cpd), B: 6 cpd, C: 12 cpd, D: 18 cpd) were 1.64 ± 0.14, 1.77 ± 0.18, 1.44 ± 0.24 and 0.98 ± 0.24 log units, respectively. Significant differences were observed in defocus curves for photopic and mesopic conditions (p < 0.0001). A mean disturbance index of 0.28 ± 0.22 was obtained. Bilateral FineVision IOL implant achieved a full range of adequate vision, satisfactory contrast sensitivity, and a lack of significant adverse photic phenomena. Eudract Clinical Trials Registry Number: 2014-003266-2 .

1 June 2024 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
JGJavier García-Bella
Javier García-Bella
Bárbara Burgos-BlascoBárbara Burgos-Blasco
Bárbara Burgos-Blasco
BVBeatriz Vidal-Villegas
Beatriz Vidal-Villegas
NJNuria Garzón Jimenez
Nuria Garzón Jimenez
CVCelia Villanueva
Celia Villanueva
JGJulián García-Feijóo
Julián García-Feijóo
Purpose: To evaluate visual and refractive outcomes, as well as patient satisfaction after bilateral implantation of an enhanced monofocal intraocular lens (IOL) with emmetropia as a target refraction. Setting: San Carlos Hospital, Madrid, Spain. Design: Prospective, monocentric, noncomparative study. Methods: Adults 21 years or older suitable for cataract surgery and with corneal astigmatism <1.50 diopters (D) were bilaterally implanted with the RayOne EMV IOL and followed up for 3 months. Outcomes measures included refraction, monocular and binocular uncorrected distance visual acuity, corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity, distance-corrected intermediate visual acuity (DCIVA), and defocus curve, aberrometry, and satisfaction. Visual symptoms were assessed using the CatQuest-9SF questionnaire. Results: 50 eyes of 25 patients were included. At month 3, the mean manifest spherical equivalent was −0.39 ± 0.28 D, with all eyes within 1.00 D. Binocularly, uncorrected, at distance, 68% of patients could read ≤0.0 logMAR and 95% ≤0.2 logMAR; at intermediate 59% of patients could read ≤0.1 and 100% ≤0.2 logMAR. Mean monocular CDVA was −0.03 ± 0.06 logMAR and mean monocular DCIVA was 0.28 ± 0.07 logMAR. Binocular defocus curve demonstrated a visual acuity ≤0.2 logMAR over a 2 D range from +1.00 D to −1.25 D. Satisfaction was good in 96% of patients. Conclusions: Bilateral implantation of an enhanced monofocal IOL with emmetropia as a target provided excellent binocular CDVA and good DCIVA, with a high level of satisfaction.

18 April 2016 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
José Ignacio Fernández-VigoJosé Ignacio Fernández-Vigo
José Ignacio Fernández-Vigo
JGJulián García-Feijóo
Julián García-Feijóo
Jose M Martinez de la CasaJose M Martinez de la Casa
Jose M Martinez de la Casa
JGJavier García-Bella
Javier García-Bella
PVPedro Arriola Villalobos
Pedro Arriola Villalobos
José Ignacio Fernández-VigoJosé Ignacio Fernández-Vigo
José Ignacio Fernández-Vigo
Recently, novel anatomic parameters that can be measured by optical coherence tomography (OCT), have been identified as a more objective and accurate method of defining the iridocorneal angle. The aim of the present study is to measure the iridocorneal angle by Fourier domain (FD) OCT and to identify correlations between angle measurements and subject factors in a large healthy Caucasian population. A cross sectional study was performed in 989 left eyes of 989 healthy subjects. The iridocorneal angle measurements: trabecular-iris angle (TIA), angle opening distance (AOD500) and trabecular-iris space area (TISA500) 500 μm from the scleral spur, were made using the FD-OCT RTVue®. Iris thickness was also measured. Correlations were examined between angle measurements and demographic and ocular factors. The main determinants of angle width were identified by multivariate linear regression. TIA could be measured in 94 % of the eyes, and AOD500 and TISA500 in 92 %. The means recorded were TIA 35.8 ± 12.2 degrees (range 1.5 to 76.1), AOD500 542.6 ± 285.4 μm (range 15 to 1755), and TISA500 0.195 ± 0.104 mm2 (range 0.02 to 0.62). The correlation between the temporal and nasal quadrant was R = 0.902 for TIA. The reproducibility of measurements was excellent (intraclass correlation coefficient >0.947). Mean angle width measurements were smaller in women (p = 0.02). Correlation was detected between angle means and anterior chamber volume (ACV; R = 0.848), anterior chamber depth (ACD; R = 0.818), spherical error (R = -0.619) and age (R = -0.487), while no correlation was observed with Intraocular pressure (R = -0.052). ACV emerged as the main determinant of TIA (R2 = 0.705; p < 0.001). In this Caucasian population, strong correlation was detected between FD-OCT anterior angle measurements and ACV, ACD, spherical refractive error and sex, emerging the ACV as the main determinant of TIA.

9 November 2017 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
JGJavier García-Bella
Javier García-Bella
NVNéstor Ventura-Abreu
Néstor Ventura-Abreu
LMLaura Morales-Fernández
Laura Morales-Fernández
PTPaula Talavero-González
Paula Talavero-González
JCJesus Carballo-Alvarez
Jesus Carballo-Alvarez
Jose M Martinez de la CasaJose M Martinez de la Casa
Jose M Martinez de la Casa
Purpose: To assess photopic and mesopic vision in patients implanted with the Bi-Flex® M 677 MY bifocal intraocular lens (IOL). Methods: In this prospective clinical study, 25 patients with cataract in both eyes were subjected to cataract surgery and bilateral implantation of the Bi-Flex® M 677MY (Medicontur, Hungary) IOL. Three months after surgery, high-contrast photopic uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were determined. Intermediate at 65 cm (DCIVA) and near at 40 cm (DCNVA) visual acuity were also measured, both with best distance correction. The CSV-1000 test chart was used to assess contrast sensitivity (CS). Defocus curves were constructed under photopic and mesopic conditions, determining binocular best-corrected visual acuity over the range +1.50 D to -4.00 D in 0.50-D steps. A KR-1W Wavefront Analyzer was used to measure pupil size and aberrometric outcomes. Presence and type of dysphotopsia were evaluated with the Likert scale. Results: Mesopic mean pupil diameter was 4.58 ± 0.73 mm. The mean values at 3 months were UDVA 0.03 ± 0.09, CDVA -0.05 ± 0.06, DCIVA 0.20 ± 0.07, and DCNVA 0.11 ± 0.08. Mean CS for the 4 frequencies examined were 1.66 ± 0.16, 1.75 ± 0.14, 1.39 ± 0.22, and 0.96 ± 0.19. Significant differences were observed in defocus curves for photopic and mesopic conditions. A significant correlation between pupil diameter and the dysphotopic photopic was found (r = 0.62; p = 0.02). Conclusions: The evaluated progressive apodized diffractive design IOL provides effective restoration of visual function in far and near vision distance with an adequate intermediate visual quality between -1.00 and -1.50 focus.

11 June 2018 in Eye
Verified
Journal Article
Closed access
PDF file
JGJavier García-Bella
Javier García-Bella
PTPaula Talavero-González
Paula Talavero-González
JCJesus Carballo-Alvarez
Jesus Carballo-Alvarez
JSJuan C. Sanz-Fernández
Juan C. Sanz-Fernández
JVJosé M. Vázquez-Moliní
José M. Vázquez-Moliní
Jose M Martinez de la CasaJose M Martinez de la Casa
Jose M Martinez de la Casa

1 August 2016 in Archivos de la Sociedad Española de Oftalmología
Verified
Journal Article
Closed access
JGJavier García-Bella
Javier García-Bella
JDJUAN DONATE-LOPEZ
JUAN DONATE-LOPEZ
RGR. Gallego-Pinazo
R. Gallego-Pinazo
JCJ.M. Benítez del Castillo
J.M. Benítez del Castillo