Tri Vu

Dr. Tri Vu


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2020 in Experimental Biology and Medicine
Verified
Journal Article
Open access
PDF file
TVTri Vu
Tri Vu
MLMucong Li
Mucong Li
HHHannah Humayun
Hannah Humayun
YZYuan Zhou
Yuan Zhou
JYJunjie Yao
Junjie Yao
This study has the following main impacts. It offers a promising solution for removing limited-view and limited-bandwidth artifact in PACT using a linear-array transducer and conventional image reconstruction, which have long hindered its clinical translation. Our solution shows unprecedented artifact removal ability for in vivo image, which may enable important applications such as imaging tumor angiogenesis and hypoxia. The study reports, for the first time, the use of an advanced deep-learning model based on stabilized generative adversarial network. Our results have demonstrated its superiority over other state-of-the-art deep-learning methods.

1 June 2021 in Photoacoustics
Verified
Journal Article
Open access
TVTri Vu
Tri Vu
ADAnthony DiSpirito
Anthony DiSpirito
DLDaiwei Li
Daiwei Li
ZWZixuan Wang
Zixuan Wang
XZXiaoyi Zhu
Xiaoyi Zhu
JYJunjie Yao
Junjie Yao
Photoacoustic microscopy (PAM) is an emerging imaging method combining light and sound. However, limited by the laser’s repetition rate, state-of-the-art high-speed PAM technology often sacrifices spatial sampling density (i.e., undersampling) for increased imaging speed over a large field-of-view. Deep learning (DL) methods have recently been used to improve sparsely sampled PAM images; however, these methods often require time-consuming pre-training and large training dataset with ground truth. Here, we propose the use of deep image prior (DIP) to improve the image quality of undersampled PAM images. Unlike other DL approaches, DIP requires neither pre-training nor fully-sampled ground truth, enabling its flexible and fast implementation on various imaging targets. Our results have demonstrated substantial improvement in PAM images with as few as 1.4 % of the fully sampled pixels on high-speed PAM. Our approach outperforms interpolation, is competitive with pre-trained supervised DL method, and is readily translated to other high-speed, undersampling imaging modalities.

25 June 2021 in JID Innovations
Verified
Journal Article
Open access
DLDaiwei Li
Daiwei Li
LHLucas Humayun
Lucas Humayun
EVEmelina Vienneau
Emelina Vienneau
TVTri Vu
Tri Vu
JYJunjie Yao
Junjie Yao
Skin diseases are the most common human diseases and manifest in distinct structural and functional changes to skin tissue components such as basal cells, vasculature, and pigmentation. Although biopsy is the standard practice for skin disease diagnosis, it is not sufficient to provide in vivo status of the skin and highly depends on the timing of diagnosis. Noninvasive imaging technologies that can provide structural and functional tissue information in real time would be invaluable for skin disease diagnosis and treatment evaluation. Among the modern medical imaging technologies, photoacoustic (PA) tomography (PAT) shows great promise as an emerging optical imaging modality with high spatial resolution, high imaging speed, deep penetration depth, rich contrast, and inherent sensitivity to functional and molecular information. Over the last decade, PAT has undergone an explosion in technical development and biomedical applications. Particularly, PAT has attracted increasing attention in skin disease diagnosis, providing structural, functional, metabolic, molecular, and histological information. In this concise review, we introduce the principles and imaging capability of various PA skin imaging technologies. We highlight the representative applications in the past decade with a focus on imaging skin vasculature and melanoma. We also envision the critical technical developments necessary to further accelerate the translation of PAT technologies to fundamental skin research and clinical impacts.

29 September 2023 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
TVTri Vu
Tri Vu
PKPaul Klippel
Paul Klippel
ACAidan J. Canning
Aidan J. Canning
CMChenshuo Ma
Chenshuo Ma
HZHuijuan Zhang
Huijuan Zhang
JYJunjie Yao
Junjie Yao
In photoacoustic computed tomography (PACT) with short-pulsed laser excitation, wideband acoustic signals are generated in biological tissues with frequencies related to the effective shapes and sizes of the optically absorbing targets. Low-frequency photoacoustic signal components correspond to slowly varying spatial features and are often omitted during imaging due to the limited detection bandwidth of the ultrasound transducer, or during image reconstruction as undesired background that degrades image contrast. Here we demonstrate that low-frequency photoacoustic signals, in fact, contain functional and molecular information, and can be used to enhance structural visibility, improve quantitative accuracy, and reduce spare-sampling artifacts. We provide an in-depth theoretical analysis of low-frequency signals in PACT, and experimentally evaluate their impact on several representative PACT applications, such as mapping temperature in photothermal treatment, measuring blood oxygenation in a hypoxia challenge, and detecting photoswitchable molecular probes in deep organs. Our results strongly suggest that low-frequency signals are important for functional and molecular PACT.

10 August 2021 in Biomedical Optics Express
Verified
Journal Article
Closed access
TVTri Vu
Tri Vu
YTYuqi Tang
Yuqi Tang
MLMucong Li
Mucong Li
GSGeorgii Sankin
Georgii Sankin
STShanshan Tang
Shanshan Tang
JYJunjie Yao
Junjie Yao
Mechanical high-intensity focused ultrasound (HIFU) has been used for cancer treatment and drug delivery. Existing monitoring methods for mechanical HIFU therapies such as MRI and ultrasound imaging often suffer from high cost, poor spatial-temporal resolution, and/or low sensitivity to tissue’s hemodynamic changes. Evaluating vascular injury during mechanical HIFU treatment, therefore, remains challenging. Photoacoustic computed tomography (PACT) is a promising tool to meet this need. Intrinsically sensitive to optical absorption, PACT provides high-resolution imaging of blood vessels using hemoglobin as the endogenous contrast. In this study, we have developed an integrated HIFU-PACT system for detecting vascular rupture in mechanical HIFU treatment. We have demonstrated singular value decomposition for enhancing hemorrhage detection. We have validated the HIFU-PACT performance on phantoms and in vivo animal tumor models. We expect that PACT-HIFU will find practical applications in oncology research using small animal models.