Emelina Vienneau

Emelina Vienneau

Auto-generated profile, based on publicly available information

Emelina Vienneau

Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2021 in JID Innovations
Verified
Journal Article
Open access
DLDaiwei Li
Daiwei Li
LHLucas Humayun
Lucas Humayun
EVEmelina Vienneau
Emelina Vienneau
TVTri Vu
Tri Vu
JYJunjie Yao
Junjie Yao
Skin diseases are the most common human diseases and manifest in distinct structural and functional changes to skin tissue components such as basal cells, vasculature, and pigmentation. Although biopsy is the standard practice for skin disease diagnosis, it is not sufficient to provide in vivo status of the skin and highly depends on the timing of diagnosis. Noninvasive imaging technologies that can provide structural and functional tissue information in real time would be invaluable for skin disease diagnosis and treatment evaluation. Among the modern medical imaging technologies, photoacoustic (PA) tomography (PAT) shows great promise as an emerging optical imaging modality with high spatial resolution, high imaging speed, deep penetration depth, rich contrast, and inherent sensitivity to functional and molecular information. Over the last decade, PAT has undergone an explosion in technical development and biomedical applications. Particularly, PAT has attracted increasing attention in skin disease diagnosis, providing structural, functional, metabolic, molecular, and histological information. In this concise review, we introduce the principles and imaging capability of various PA skin imaging technologies. We highlight the representative applications in the past decade with a focus on imaging skin vasculature and melanoma. We also envision the critical technical developments necessary to further accelerate the translation of PAT technologies to fundamental skin research and clinical impacts.

20 April 2023 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
EVEmelina P. Vienneau
Emelina P. Vienneau
BBBrett C. Byram
Brett C. Byram
Robust transcranial ultrasound imaging is difficult due to poor image quality. In particular, low signal-to-noise ratio (SNR) limits sensitivity to blood flow and has hindered clinical translation of transcranial functional ultrasound neuroimaging thus far. In this work, we present a coded excitation framework to increase SNR in transcranial ultrasound without negatively impacting frame rate or image quality. We applied this coded excitation framework in phantom imaging and showed SNR gains as large as 24.78 dB and signal-to-clutter ratio gains as high as 10.66 dB with a 65 bit code. We also analyzed how imaging sequence parameters can impact image quality and showed how coded excitation sequences can be designed to maximize image quality for a given application. In particular, we show that considering the number of active transmit elements and the transmit voltage is critical for coded excitation with long codes. Finally, we applied our coded excitation technique in transcranial imaging of ten adult subjects and showed an average SNR gain of 17.91 ± 0.96 dB without a significant increase in clutter using a 65 bit code. We also performed transcranial power Doppler imaging in three adult subjects and showed contrast and contrast-to-noise ratio improvements of 27.32 ± 8.08 dB and 7.25 ± 1.61 dB, respectively with a 65 bit code. These results show that transcranial functional ultrasound neuroimaging may be possible using coded excitation.

11 September 2018 in Optics Letters
Verified
Journal Article
Closed access
PDF file
EVEmelina Vienneau
Emelina Vienneau
Wei LiuWei Liu
Wei Liu
JYJunjie Yao
Junjie Yao
Acoustic-resolution photoacoustic microscopy (AR-PAM) can provide penetration depths beyond the optical diffusion limit, but its lateral resolution is typically much worse than its axial resolution, resulting in a low-resolution isotropy. We herein present a dual-view AR-PAM (DV-AR-PAM) system that exploits two orthogonally arranged focused ultrasonic transducers. Taking advantage of their complementary acoustic detecting profiles, DV-AR-PAM allows the fusion of the dual-view signals, resulting in an enhancement in the resolution isotropy from 29% to 95% within one imaging plane, as demonstrated by simulation results on densely packed particles and experimental results on a single carbon fiber. The application of this method in vivo revealed distinct microvasculature structures in mouse skin that were previously indistinguishable with single-view detection, demonstrating the potential of DV-AR-PAM for vascular and neurological studies.

3 October 2017 in Journal of Biophotonics
Verified
Journal Article
Closed access
PDF file
Wei LiuWei Liu
Wei Liu
YZYuan Zhou
Yuan Zhou
MWMengran Wang
Mengran Wang
LLLei Li
Lei Li
EVEmelina Vienneau
Emelina Vienneau
JYJunjie Yao
Junjie Yao

30 March 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
EVEmelina P. Vienneau
Emelina P. Vienneau
KOKathryn A. Ozgun
Kathryn A. Ozgun
BBBrett C. Byram
Brett C. Byram
Thermal noise and acoustic clutter signals degrade ultrasonic image quality and contribute to unreliable clinical assessment. When both noise and clutter are prevalent, it is difficult to determine which one is a more significant contributor to image degradation because there is no way to separately measure their contributions in vivo . Efforts to improve image quality often rely on an understanding of the type of image degradation at play. To address this, we derived and validated a method to quantify the individual contributions of thermal noise and acoustic clutter to image degradation by leveraging spatial and temporal coherence characteristics. Using Field II simulations, we validated the assumptions of our method, explored strategies for robust implementation, and investigated its accuracy and dynamic range. We further proposed a novel robust approach for estimating spatial lag-one coherence. Using this robust approach, we determined that our method can estimate the signal-to-thermal noise ratio (SNR) and signal-to-clutter ratio (SCR) with high accuracy between SNR levels of −30 to 40 dB and SCR levels of −20 to 15 dB. We further explored imaging parameter requirements with our Field II simulations and determined that SNR and SCR can be estimated accurately with as few as two frames and sixteen channels. Finally, we demonstrate in vivo feasibility in brain imaging and liver imaging, showing that it is possible to overcome the constraints of in vivo motion using high-frame rate M-Mode imaging.

21 November 2019
Verified
Book Chapter
Closed access
PDF file
EVEmelina Vienneau
Emelina Vienneau
TVTri Vu
Tri Vu
JYJunjie Yao
Junjie Yao