Kenneth Alexander McIsaac

Dr. Kenneth Alexander McIsaac


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Journal of the Neurological Sciences
Verified
Journal Article
Closed access
Mehdi DelrobaeiMehdi Delrobaei
Mehdi Delrobaei
SMSara Memar
Sara Memar
MPMarcus Pieterman
Marcus Pieterman
TSTyler W. Stratton
Tyler W. Stratton
KMKenneth Alexander McIsaac
Kenneth Alexander McIsaac
Mandar JogMandar Jog
Mandar Jog

13 June 2019 in IEEE Transactions on Systems, Man, and Cybernetics: Systems
Verified
Journal Article
Closed access
HHHashim Hashim
Hashim Hashim
LBLyndon J. Brown
Lyndon J. Brown
KMKenneth Alexander McIsaac
Kenneth Alexander McIsaac
Two novel nonlinear pose (i.e., attitude and position) filters developed directly on the Special Euclidean Group SE(3) able to guarantee prescribed characteristics of transient and steady-state performance are proposed. The position error and normalized Euclidean distance of attitude error are trapped to arbitrarily start within a given large set and converge systematically and asymptotically to the origin from almost any initial condition. The transient error is guaranteed not to exceed a prescribed value while the steady-state error is bounded by a predefined small value. The first pose filter operates based on a set of vectorial measurements coupled with a group of velocity vectors and requires preliminary pose reconstruction. The second filter, on the contrary, is able to perform its function using a set of vectorial measurements and a group of velocity vectors directly. Both proposed filters provide reasonable pose estimates with superior convergence properties while being able to use measurements obtained from low-cost inertial measurement, landmark measurement, and velocity measurement units. The simulation results demonstrate the effectiveness and robustness of the proposed filters considering large error in initialization and high level of uncertainties in velocity vectors as well as in the set of vector measurements.

16 May 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
RBRiley Aaron Bloomfield
Riley Aaron Bloomfield
MFMegan Christine Fennema
Megan Christine Fennema
KMKenneth Alexander McIsaac
Kenneth Alexander McIsaac
MTMatthew G. Teeter
Matthew G. Teeter
Objective: Currently, most measurements of knee joint function are obtained through observation and patient-reported outcomes. This paper proposes an implementation and validation of a knee monitor to measure quantitative joint data in multiple degrees of freedom. The proposed system is configurable with minimal patient interaction and no frame-alignment calibration procedure is required for measurement after visually placing/replacing sensors on patients. Methods: A mobile software system was developed using a method of extracting clinical knee angles based on attitude estimations from independent wearable sensors. Validation was performed using a robot phantom and results were compared with a gold standard motion capture system. Two instrumentation placements (lateral and posterior) were examined. Results: A posterior sensor placement was determined to provide the most repeatable results through multiple degrees of freedom and measurement accuracy approached a gold standard motion capture technology with low root mean square error (flexion: 3.34°, internal/external rotation: 2.18°, varus/valgus: 1.44°). Conclusion: The proposed system is simple to use and convenient for use in ambulatory or unsupervised environments for joint measurement, however, it was shown that accuracy can be sensitive to sensor placement. Significance: This system would be beneficial for obtaining quantitative patient data or tracking functional activity in variable environments, providing clinicians with indications of how patients' knees function during activity, potentially permitting more individualized care and recommendations.

16 May 2018 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
LSLei Shu
Lei Shu
KMKenneth Alexander McIsaac
Kenneth Alexander McIsaac
GOGordon Osinski
Gordon Osinski
Jointly combining the spatial and spectral features has proved to dramatically improve the performance of classifying hyperspectral image. Recently, utilizing neural networks to automatically model the spatial-spectral feature representations for hyperspectral images has become of great interest. This paper proposes a simple but innovative framework to classify hyperspectral image with two shallow convolutional neural networks (CNNs). First, principal component analysis whitening is applied to decorrelate hundreds of spectral bands. Instead of selecting the principal components to reduce the spectral dimensionality, we retain all the spectral bands but compress the image cuboid into a one-channel spectral quilt by stacking spectral patches. In this way, not only all the spectral information is retained but also the computational complexity of training a neural network is reduced compared with conventional networks that directly input the spectral volumes. Moreover, the spectral quilt will contain some novel textural patterns that are effective at distinguishing classes. Two shallow CNNs are then applied to classify the spectral quilts. As shown in the experiments, both networks can outperform the standard analysis methods.

29 April 2021 in Remote Sensing
Verified
Journal Article
Open access
PDF file
HMHadis Madani
Hadis Madani
KMKenneth Alexander McIsaac
Kenneth Alexander McIsaac
Pixel-wise classification of hyperspectral images (HSIs) from remote sensing data is a common approach for extracting information about scenes. In recent years, approaches based on deep learning techniques have gained wide applicability. An HSI dataset can be viewed either as a collection of images, each one captured at a different wavelength, or as a collection of spectra, each one associated with a specific point (pixel). Enhanced classification accuracy is enabled if the spectral and spatial information are combined in the input vector. This allows simultaneous classification according to spectral type but also according to geometric relationships. In this study, we proposed a novel spatial feature vector which improves accuracies in pixel-wise classification. Our proposed feature vector is based on the distance transform of the pixels with respect to the dominant edges in the input HSI. In other words, we allow the location of pixels within geometric subdivisions of the dataset to modify the contribution of each pixel to the spatial feature vector. Moreover, we used the extended multi attribute profile (EMAP) features to add more geometric features to the proposed spatial feature vector. We have performed experiments with three hyperspectral datasets. In addition to the Salinas and University of Pavia datasets, which are commonly used in HSI research, we include samples from our Surrey BC dataset. Our proposed method results compares favorably to traditional algorithms as well as to some recently published deep learning-based algorithms.

23 July 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
RBRiley A. Bloomfield
Riley A. Bloomfield
MTMatthew G. Teeter
Matthew G. Teeter
KMKenneth Alexander McIsaac
Kenneth Alexander McIsaac
Wearable sensors permit convenient human activity data collection in diverse environments and collected data can be used to evaluate functional impairment or analyze recovery following surgical interventions such as knee replacement. Automated activity classification can be used for adding context to unscripted sessions for comparing identical tasks across subjects. In this study, twenty participants were instrumented with wearable inertial sensors placed above and below both knees while performing activities of daily living. Collected multivariate time series data were encoded as colour images and three convolutional neural networks were developed to classify activities into eleven classes. Performance was evaluated using twenty iterations of a leave-one-subject-out scheme. A first-stage classification model was able to differentiate static vs. dynamic activities almost perfectly and a second-stage model was able to further classify specific static activities performed with 99% accuracy. A separate second-stage model was developed to classify dynamic activities with 91% accuracy. Cycling and ascending/descending stairs were the most commonly confused activities. The current work has demonstrated that both static and dynamic activities of daily living can be classified using only leg instrumentation which is beneficial for applications studying knee performance in varying environments.