Riley Aaron Bloomfield

Riley Aaron Bloomfield

Auto-generated profile, based on publicly available information

Riley Aaron Bloomfield

Department of Electrical & Computer Engineering, Western University, London, CA, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in The Journal of Arthroplasty
Verified
Journal Article
Open access
RBRiley A. Bloomfield
Riley A. Bloomfield
HWHarley A. Williams
Harley A. Williams
JBJordan S. Broberg
Jordan S. Broberg
BLBrent A. Lanting
Brent A. Lanting
KMKenneth A. McIsaac
Kenneth A. McIsaac
MTMatthew G. Teeter
Matthew G. Teeter
Wearable sensors permit efficient data collection and unobtrusive systems can be used for instrumenting knee patients for objective assessment. Machine learning can be leveraged to parse the abundant information these systems provide and segment patients into relevant groups without specifying group membership criteria. The objective of this study is to examine functional parameters influencing favorable recovery outcomes by separating patients into functional groups and tracking them through clinical follow-ups. Patients undergoing primary unilateral total knee arthroplasty (n = 68) completed instrumented timed-up-and-go tests preoperatively and at their 2-, 6-, and 12-week follow-up appointments. A custom wearable system extracted 55 metrics for analysis and a K-means algorithm separated patients into functionally distinguished groups based on the derived features. These groups were analyzed to determine which metrics differentiated most and how each cluster improved during early recovery. Patients separated into 2 clusters (n = 46 and n = 22) with significantly different test completion times (12.6 s vs 21.6 s, P < .001). Tracking the recovery of both groups to their 12-week follow-ups revealed 64% of one group improved their function while 63% of the other maintained preoperative function. The higher improvement group shortened their test times by 4.94 s, (P = .005) showing faster recovery while the other group did not improve above a minimally important clinical difference (0.87 s, P = .07). Features with the largest effect size between groups were distinguished as important functional parameters. This work supports using wearable sensors to instrument functional tests during clinical visits and using machine learning to parse complex patterns to reveal clinically relevant parameters.

1 January 2019 in The Knee
Verified
Journal Article
Open access
MFM.C. Fennema
M.C. Fennema
RBR.A. Bloomfield
R.A. Bloomfield
BLB.A. Lanting
B.A. Lanting
TBT.B. Birmingham
T.B. Birmingham
MTM.G. Teeter
M.G. Teeter
As assessment with inertial-measurement-units (IMUs) increases in research and in clinics, it is important to be aware of the repeatability of these sensors. The objectives of this experiment were to evaluate the measurement repeatability of IMU joint angles using a repeatable robot controller and an anthropomorphic leg phantom and to determine effects of joint speed and sensor positioning on the angles collected by these sensors. Comparisons to an electro-goniometer and three-dimensional (3D) motion capture cameras were also completed. Two dual-IMU setups (posterior and lateral) were tested concurrently with an electro-goniometer and 3D motion capture cameras using a repeatable robot controller and a leg phantom. All modalities were attached to the phantom, which was flexed 10 times using a pre-programmed motion pathway during each test. Mean angles were compared across tests. Effects of joint speed, sensor re-positioning, and anatomical placement of the sensors on repeatability were assessed. Re-positioning caused greater deviation to the maximum and minimum angles than differences in speed. Overall, the means ± standard deviations, and 95% confidence intervals of the maximum angles across all tests for the 3D camera markers, electro-goniometer, posterior IMUs, and lateral IMUs were 119.4 ± 0.3° (119.4, 119.5), 112.4 ± 0.5° (112.3, 112.5), 116.2 ± 2.4° (115.7, 116.7), and 118.3 ± 1.1° (118.1, 118.6). Both posterior and lateral IMU setups demonstrated acceptable repeatability in measurement of range of motion that was advantageous to manual goniometer methods. Posterior and lateral IMU setups demonstrated overlapping standard deviations about their means.

16 May 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
RBRiley Aaron Bloomfield
Riley Aaron Bloomfield
MFMegan Christine Fennema
Megan Christine Fennema
KMKenneth Alexander McIsaac
Kenneth Alexander McIsaac
MTMatthew G. Teeter
Matthew G. Teeter
Objective: Currently, most measurements of knee joint function are obtained through observation and patient-reported outcomes. This paper proposes an implementation and validation of a knee monitor to measure quantitative joint data in multiple degrees of freedom. The proposed system is configurable with minimal patient interaction and no frame-alignment calibration procedure is required for measurement after visually placing/replacing sensors on patients. Methods: A mobile software system was developed using a method of extracting clinical knee angles based on attitude estimations from independent wearable sensors. Validation was performed using a robot phantom and results were compared with a gold standard motion capture system. Two instrumentation placements (lateral and posterior) were examined. Results: A posterior sensor placement was determined to provide the most repeatable results through multiple degrees of freedom and measurement accuracy approached a gold standard motion capture technology with low root mean square error (flexion: 3.34°, internal/external rotation: 2.18°, varus/valgus: 1.44°). Conclusion: The proposed system is simple to use and convenient for use in ambulatory or unsupervised environments for joint measurement, however, it was shown that accuracy can be sensitive to sensor placement. Significance: This system would be beneficial for obtaining quantitative patient data or tracking functional activity in variable environments, providing clinicians with indications of how patients' knees function during activity, potentially permitting more individualized care and recommendations.

24 December 2020 in Medical Engineering & Physics
Verified
Journal Article
Closed access
RBRiley A. Bloomfield
Riley A. Bloomfield
JBJordan S. Broberg
Jordan S. Broberg
HWHarley A. Williams
Harley A. Williams
BLBrent A. Lanting
Brent A. Lanting
KMKenneth A. McIsaac
Kenneth A. McIsaac
MTMatthew G. Teeter
Matthew G. Teeter
Unmet expectations contribute to a high patient dissatisfaction rate following total knee replacement but clinicians currently do not have the tools to confidently adjust expectations. In this study, supervised machine learning was applied to multi-variate wearable sensor data from preoperative timed-up-and-go tests. Participants (n=82) were instrumented three months after surgery and patients showing relevant improvement were designated as "responders" while the remainder were labelled "maintainers". Support vector machine, naïve Bayes, and random forest binary classifiers were developed to distinguish patients using sensor-derived features. Accuracy, sensitivity, specificity, and area under the receiver-operator curve (AUC) were compared between models using ten-fold out-of-sample testing. A high performance using only sensor-derived functional metrics was obtained with a random forest model (accuracy = 0.76 ± 0.11, sensitivity = 0.87 ± 0.08, specificity = 0.57 ± 0.26, AUC = 0.80 ± 0.14) but highly sensitive models were observed using naïve Bayes and SVM models after including patient age, sex, and BMI into the feature set (accuracy = 0.72, 0.73 ± 0.09, 0.12; sensitivity = 0.94, 0.95 ± 0.11, 0.11; specificity = 0.35, 0.37 ± 0.20, 0.18; AUC = 0.80, 0.74 ± 0.07, 0.11; respectfully). Including select patient-reported subjective measures increased the top random forest performance slightly (accuracy = 0.80 ± 0.10, sensitivity = 0.91 ± 0.14, specificity = 0.62 ± 0.23, AUC = 0.86 ± 0.09). The current work has demonstrated that prediction models developed from preoperative sensor-derived functional metrics can reliably predict expected functional recovery following surgery and this can be used by clinicians to help set realistic patient expectations.

23 July 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
RBRiley A. Bloomfield
Riley A. Bloomfield
MTMatthew G. Teeter
Matthew G. Teeter
KMKenneth Alexander McIsaac
Kenneth Alexander McIsaac
Wearable sensors permit convenient human activity data collection in diverse environments and collected data can be used to evaluate functional impairment or analyze recovery following surgical interventions such as knee replacement. Automated activity classification can be used for adding context to unscripted sessions for comparing identical tasks across subjects. In this study, twenty participants were instrumented with wearable inertial sensors placed above and below both knees while performing activities of daily living. Collected multivariate time series data were encoded as colour images and three convolutional neural networks were developed to classify activities into eleven classes. Performance was evaluated using twenty iterations of a leave-one-subject-out scheme. A first-stage classification model was able to differentiate static vs. dynamic activities almost perfectly and a second-stage model was able to further classify specific static activities performed with 99% accuracy. A separate second-stage model was developed to classify dynamic activities with 91% accuracy. Cycling and ascending/descending stairs were the most commonly confused activities. The current work has demonstrated that both static and dynamic activities of daily living can be classified using only leg instrumentation which is beneficial for applications studying knee performance in varying environments.