Megan Christine Fennema

Megan Christine Fennema

Auto-generated profile, based on publicly available information

Megan Christine Fennema

Lawson Health Research Institute, Robarts Research Institute, Department of Medical Biophysics, Western University, London, ON, Canada

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in The Knee
Verified
Journal Article
Open access
MFM.C. Fennema
M.C. Fennema
RBR.A. Bloomfield
R.A. Bloomfield
BLB.A. Lanting
B.A. Lanting
TBT.B. Birmingham
T.B. Birmingham
MTM.G. Teeter
M.G. Teeter
As assessment with inertial-measurement-units (IMUs) increases in research and in clinics, it is important to be aware of the repeatability of these sensors. The objectives of this experiment were to evaluate the measurement repeatability of IMU joint angles using a repeatable robot controller and an anthropomorphic leg phantom and to determine effects of joint speed and sensor positioning on the angles collected by these sensors. Comparisons to an electro-goniometer and three-dimensional (3D) motion capture cameras were also completed. Two dual-IMU setups (posterior and lateral) were tested concurrently with an electro-goniometer and 3D motion capture cameras using a repeatable robot controller and a leg phantom. All modalities were attached to the phantom, which was flexed 10 times using a pre-programmed motion pathway during each test. Mean angles were compared across tests. Effects of joint speed, sensor re-positioning, and anatomical placement of the sensors on repeatability were assessed. Re-positioning caused greater deviation to the maximum and minimum angles than differences in speed. Overall, the means ± standard deviations, and 95% confidence intervals of the maximum angles across all tests for the 3D camera markers, electro-goniometer, posterior IMUs, and lateral IMUs were 119.4 ± 0.3° (119.4, 119.5), 112.4 ± 0.5° (112.3, 112.5), 116.2 ± 2.4° (115.7, 116.7), and 118.3 ± 1.1° (118.1, 118.6). Both posterior and lateral IMU setups demonstrated acceptable repeatability in measurement of range of motion that was advantageous to manual goniometer methods. Posterior and lateral IMU setups demonstrated overlapping standard deviations about their means.

16 May 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
RBRiley Aaron Bloomfield
Riley Aaron Bloomfield
MFMegan Christine Fennema
Megan Christine Fennema
KMKenneth Alexander McIsaac
Kenneth Alexander McIsaac
MTMatthew G. Teeter
Matthew G. Teeter
Objective: Currently, most measurements of knee joint function are obtained through observation and patient-reported outcomes. This paper proposes an implementation and validation of a knee monitor to measure quantitative joint data in multiple degrees of freedom. The proposed system is configurable with minimal patient interaction and no frame-alignment calibration procedure is required for measurement after visually placing/replacing sensors on patients. Methods: A mobile software system was developed using a method of extracting clinical knee angles based on attitude estimations from independent wearable sensors. Validation was performed using a robot phantom and results were compared with a gold standard motion capture system. Two instrumentation placements (lateral and posterior) were examined. Results: A posterior sensor placement was determined to provide the most repeatable results through multiple degrees of freedom and measurement accuracy approached a gold standard motion capture technology with low root mean square error (flexion: 3.34°, internal/external rotation: 2.18°, varus/valgus: 1.44°). Conclusion: The proposed system is simple to use and convenient for use in ambulatory or unsupervised environments for joint measurement, however, it was shown that accuracy can be sensitive to sensor placement. Significance: This system would be beneficial for obtaining quantitative patient data or tracking functional activity in variable environments, providing clinicians with indications of how patients' knees function during activity, potentially permitting more individualized care and recommendations.