Hojjat Ghahramanzadeh Asl

Dr. Hojjat Ghahramanzadeh Asl

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2023 in Medical Engineering & Physics
Verified
Journal Article
Closed access
DKDerya Karaman
Derya Karaman
HAHojjat Ghahramanzadeh Asl
Hojjat Ghahramanzadeh Asl
Triply periodic minimal surface (TPMS) is known mathematically as a surface with mean curvature of zero and replicated in three directions infinitely. Providing the pore combination in porous structures with surface connections, they provide large surface areas. This study aims to determine the effects of the network solid and sheet solid structures in the three different TPMS architectures on bone regeneration. Evaluation is made for Diamond, Gyroid, and I-WP structures, which are widely preferred architectures in terms of mechanical strength. Scaffolds are modeled as both network solid and sheet solid unit cells with similar porosities (60%, 70%, and 80%). Flow analyses are performed with the Computational Fluid Dynamics method to determine of potential for bone cell development of scaffolds. The permeability, wall shear stress on the surfaces, and the flow velocity distribution of the scaffolds are obtained with these analyses. The permeability value of 18 scaffolds is between the permeability values determined for trabecular bone. The permeability of network solid TPMS scaffolds for the same architectures is higher than sheet solid TPMS scaffolds due to the low pressures generated. The maximum wall shear stress in scaffolds decreases as porosity increases. Since the maximum wall shear stresses occur in less than 0.1% area on the scaffold surfaces, it is more appropriate to examine distribution of these stresses on the scaffold surfaces. Sheet solid structures within TPMS are more advantageous for biomechanical environments due to their greater surface area at similar porosities, wall shear stress, and permeability values.

6 September 2019 in Materials and Corrosion
Verified
Journal Article
Closed access
PDF file
ÖBÖzgü Bayrak
Özgü Bayrak
HAHojjat Ghahramanzadeh Asl
Hojjat Ghahramanzadeh Asl
AAAyşe AK
Ayşe AK

12 April 2022 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
DKDerya Karaman
Derya Karaman
HAHojjat Ghahramanzadeh Asl
Hojjat Ghahramanzadeh Asl
Scaffolds provide a suitable environment for the bone tissue to maintain its self-healing ability and help new bone-cell formation by creating structures with similar mechanical properties to the surrounding tissue. In the modeling of the scaffolds, an optimum environment is tried to be provided by changing the geometrical properties of the cell architecture such as porosity, pore size, and specific surface area. For this purpose, different design approaches have been used in studies to change these properties. This study aims to determine whether scaffolds with similar porosities modeled by different design approaches exhibit distinct biomechanical behaviors or not. By using the Diamond lattice architecture, two different design approaches were constituted. The first approach has constant wall thickness and variable cell size, whereas the second approach contains variable wall thickness and constant cell size. The usage of different design approaches affected the amount of specific surface area in models with similar porosity. Mechanical compression tests were conducted via finite element analysis, while the permeability performance of configurations with similar porosities (50%, 60%, 70%, 80%, and 90%) was evaluated by using computational fluid dynamics. The mechanical results revealed that the structural strength decreased with increasing porosity. Since their higher specific surface area causes lower pressure drops, the second group exhibits better permeability. In addition, it was found that to evaluate the wall shear stresses occurring on the scaffold surfaces properly, it is essential to consider the stress distributions within the scaffold rather than the maximum values.

3 March 2022 in Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications
Verified
Journal Article
Closed access
YSYaşar Sert
Yaşar Sert
HAHojjat Ghahramanzadeh Asl
Hojjat Ghahramanzadeh Asl
TKTevfik Küçükömeroğlu
Tevfik Küçükömeroğlu
It is known that the interest in manufacturing in a vacuum environment has increased in recent years. Thus, the wear behavior of mechanical tools under vacuum conditions has critical importance. However, adhesion and cold-welding problems between tool and working piece in vacuum conditions lead to poor wear properties and severe coefficient of friction values. Surface treatment methods such as physical vapor deposition coatings can eliminate these undesirable consequences, especially transition metal nitrides. In this study, TiAlN, TiSiN, and TiAlN/TiSiN films were coated on AISI H13 tool steels employing the cathodic arc evaporation technique. Whether the coatings grown to the substrate surface have a positive contribution to the wear performance of the substrate in the ambient air and vacuum environment was answered. Scanning electron microscope, energy dispersive spectrometer, and X-ray diffractometer analyses were used to attain structural properties. The hardness was measured using a nano-hardness tester, and the adhesion properties were determined by a scratch test. The wear behavior of the substrate and coating samples are determined under 2 N constant normal load and using WC-6%Co counter bodies under ambient air and vacuum conditions. The hardness of samples improved owing to surface coatings, and the highest nano-hardness value was determined from the TiSiN coatings as 39.42 GPa, which is ∼700% greater than the substrate. It has been observed that coated samples have superior wear performance in both wear conditions. Besides, it is determined that those tested under a vacuum condition showed superior wear resistance than the samples tested under ambient air. While TiSiN film exhibits the highest wear resistance in ambient air, the TiAlN/TiSiN layer is the best in a vacuum environment. Owing to the deposited coatings, the seizure mechanism between the friction surfaces, which is frequently encountered in the vacuum environment, is prevented, and a fascinating improvement in terms of friction coefficient is achieved.

8 November 2022 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
HAHojjat Ghahramanzadeh Asl
Hojjat Ghahramanzadeh Asl
SCSelcen Celik-Uzuner
Selcen Celik-Uzuner
UUUgur Uzuner
Ugur Uzuner
YSYaşar Sert
Yaşar Sert
TKTevfik Küçükömeroğlu
Tevfik Küçükömeroğlu
Recently, AZ31B magnesium alloy has been widely employed in automotive, aerospace, and bio implant industries due to its light-weight and biocompatibility properties. However, the equilibrium of ductility and strength of this material and the negativity brought by its poor wear behavior have limited its versatile use. Friction stir processing (FSP) has been commonly used as severe plastic deformation method for improving mechanical and tribological properties of metal sheets. The effect of this method on the biocompatibility of materials is a matter of curiosity that should be emphasized. So, the present study aims to investigate the effect of friction stir process on the mechanical, tribological, and biocompatibility properties of AZ31B magnesium alloy. It is observed that FSP enhanced the tensile properties of the alloy but decreased its elongation. It was determined that the base material exhibited ductile character on the fracture surface of the specimens, and mixed ductile/brittle fracture was evident with the FSP. In the FSP zone, the hardness value was improved by 17% compared to the base material. Also, the wear performance of the alloy enhanced in ambient air and Simulated Body Fluid (SBF) solution. Wear properties in SBF solution were better due to less adhesive bonds between the friction surfaces. This assessment was supported by SEM images of the wear path and surface of counter bodies. On the other hand, FSPed AZ31B alloy materials with improved strength properties were not cytotoxic for human gingival fibroblasts, and these results may suggest that the materials are safe for clinical uses.

31 December 2020 in Dental and Medical Problems
Verified
Journal Article
Open access
HAHojjat Ghahramanzadeh Asl
Hojjat Ghahramanzadeh Asl
AAAkgün Alsaran
Akgün Alsaran
Implants called miniplates, with different geometries, are used for the treatment of a fractured or diseased mandible. Generally, Ti-based miniplates in various quantities and with various geometries are fixed into the bone tissue according to the location and shape of the fracture by embedding. The aim of this study was to increase the strength of the material used in the production of miniplates by means of the equal-channel angular pressing (ECAP) treatment, and to provide a highrigidity fixation system with fewer miniplates. In this study, the ECAP method, which is one of the methods of severe plastic deformation, was applied at 4 passes at 300°C in route Bc to increase the strength of pure Ti. Then, miniplates were produced with 2 different geometries (regular and long) and 2 different properties of the Ti material (untreated and ECAP-treated). The produced miniplates were placed in the fracture line formed in the angular region of an artificial, synthetic-bone mandible. The 2-point and 3-point bending and torsion tests were conducted on these fixation systems. As a result, after the ECAP process, the yield and tensile strength of pure Ti increased by 65%, while elongation decreased by 13%. After the ECAP process, the grain size of the material was reduced from 110 μm to 200 nm. This study showed that the fixation system became more rigid due to using ECAP-treated miniplates, and this ensured lesser displacement of the fixation system.