Queenie Chan

Dr. Queenie Chan

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

21 November 2014 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
ELElaine Yuen Phin Lee
Elaine Yuen Phin Lee
EHEdward Sai Kam Hui
Edward Sai Kam Hui
KCKaren Kar Loen Chan
Karen Kar Loen Chan
KTKa Yu Tse
Ka Yu Tse
WKWai Kay Kwong
Wai Kay Kwong
PKPek-Lan Khong
Pek-Lan Khong
Purpose To investigate the relationship between intravoxel incoherent motion (IVIM) diffusion-weighted magnetic resonance imaging (MRI) and dynamic contrast-enhanced MRI (DCE-MRI) in cervical cancer perfusion. Materials and Methods Prospective newly diagnosed cervical cancer patients underwent diffusion-weighted MRI (13 b-values: 1–1000 s/mm2) and DCE-MRI. The IVIM perfusion parameters, perfusion fraction (f), pseudodiffusion coefficient (D*), and flow-related parameter (fD*), were derived from a biexponential decay model. DCE-MRI was analyzed with a pharmacokinetic model and signal-time curve to derive the amplitude factor (A), estimated volume transfer constant between blood plasma, and the extravascular extracellular space (estKtrans), maximum relative enhancement (MaxRE), and area under the signal-time curve (AUC). Spearman's rank correlation coefficient (r) evaluated the correlative relationships. Results The f = 13.51% ± 1.76%, D* = 71.72 ± 7.55 × 10−3 mm2/s, fD* = 9.64 ± 1.28 × 10−3 mm2/s, A = 1.41 ± 0.43, estKtrans = 0.19 ± 0.06 s−1, MaxRE of 120.02 ± 21.07%, and AUC 212,393 ± 54,423 was found in 25 cervical cancer patients. Statistically significant positive correlations were found between fD* and estKtrans (r = 0.42, P = 0.038), fD* and A (r = 0.50, P = 0.011), fD* and MaxRE (r = 0.52, P = 0.008), f and AUC (r = 0.58, P = 0.003). Conclusion: The IVIM perfusion parameters showed moderate to good correlations with quantitative and semiquantitative perfusion parameters derived from DCE-MRI in cervical cancer. J. Magn. Reson. Imaging 2014. J. Magn. Reson. Imaging 2015;42:454–459.

22 January 2020 in Cancer Imaging
Verified
Journal Article
Open access
PDF file
MSMinghui Song
Minghui Song
YYYunlong Yue
Yunlong Yue
YJYanfang Jin
Yanfang Jin
JGJinsong Guo
Jinsong Guo
LZLili Zuo
Lili Zuo
QCQueenie Chan
Queenie Chan
Background: There is a growing need for a reproducible and effective imaging method for the quantitative differentiation of benign from malignant thyroid nodules. This study aimed to investigate the performances of intravoxel incoherent motion (IVIM) parameters and the apparent diffusion coefficient (ADC) in differentiating malignant from benign thyroid nodules derived from the most repeatable region of interest (ROI) delineation. Methods: Forty-three patients with 46 pathologically confirmed thyroid nodules underwent diffusion-weighted imaging (DWI) with 8 b values. Two observers measured the intravoxel incoherent motion (IVIM) parameters (D, f and D*) and the apparent diffusion coefficient (ADC), ADC600 and ADC990 values using whole-lesion (W-L) ROI and IVIM parameters using single-section (S-S) ROI delineation. The intraclass correlation coefficients (ICCs) and Bland-Altman plots were used to evaluate the intra- and interobserver variability. The diagnostic performance of these parameters was evaluated by generating receiver operating characteristic (ROC) curves. Results: The ICC values of all IVIM with W-L ROI delineation were higher than those with S-S ROI delineation, and excellent intra- and interobserver reproducibility was obtained. According to the Bland-Altman plots, the 95% limits of agreement of the IVIM parameters determined by the W-L ROIs revealed smaller absolute intra- and interobserver variability than those determined by S-S ROIs. The D and ADC600 values obtained from the W-L ROIs were the most powerful parameters in differentiating benign from the malignant nodules [area under the ROC curve = 0.962 and 0.970, P = 0.771]. Conclusions: The W-L ROI of the thyroid was considered an effective method for obtaining IVIM measurements with excellent reproducibility for differentiating benign from malignant nodules.

23 December 2014 in European Radiology
Verified
Journal Article
Closed access
PDF file
VLVincent Lai
Vincent Lai
VLVictor Ho Fun Lee
Victor Ho Fun Lee
KLKa On Lam
Ka On Lam
HSHenry Chun Kin Sze
Henry Chun Kin Sze
QCQueenie Chan
Queenie Chan
PKPek Lan Khong
Pek Lan Khong

18 May 2016 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
SLShanshan Liu
Shanshan Liu
QZQi Zhang
Qi Zhang
CYChengying Yin
Chengying Yin
SLSong Liu
Song Liu
QCQueenie Chan
Queenie Chan
BZBin Zhu
Bin Zhu
Purpose To determine the optimal slice thickness, playback rate, and scan time for uterine peristalsis with 3.0T magnetic resonance imaging (MRI). Materials and Methods In all, 23 young female volunteers underwent a 3.0T MRI scan with different slice thicknesses of 3 mm (Cine3mm), 5 mm (Cine5mm), and 7 mm (Cine7mm) for 6 minutes. Subjective image quality score, signal‐to‐noise ratios (SNRs), and contrast‐to‐noise ratios (CNRs) of those MR images were evaluated by two radiologists independently. The number, intensity, and direction of uterine peristalsis with different thickness were compared at various playback rates. Also, the peristalsis frequency was counted and compared in different acquisition durations (1–6 minutes). Results The subjective image quality score, peristalsis number, and intensity were significantly higher in Cine7mm and Cine5mm than Cine3mm (P < 0.05), while the SNRs and CNRs of Cine7mm were significantly higher than Cine3mm (P < 0.05). Peristalsis numbers did not differ significantly at different playback rates with the same slice thickness (P = 0.548–0.962). However, peristalsis intensity at 12×, and 15× was significantly greater than that at 8× the actual speed for Cine7mm and Cine5mm (P < 0.05). The peristalsis frequency at 3, 4, 5, 6 minutes was significantly higher than that at 1 minute and 2 minutes (P < 0.05). Conclusion We recommend a slice thickness of 5 mm or 7 mm and a scan time of 3 minutes for uterine peristalsis with 3.0T MRI, and a playback rate of 12× or 15× the actual speed for peristalsis observation. J. Magn. Reson. Imaging 2016;44:1397–1404.

29 October 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
Qi Yong Hemis AiQi Yong Hemis Ai
Qi Yong Hemis Ai
WCWeitian Chen
Weitian Chen
TSTiffany So
Tiffany So
WLWai Kei Jacky Lam
Wai Kei Jacky Lam
BJB. Jiang
B. Jiang
AKAnn D. King
Ann D. King
BACKGROUND AND PURPOSE: T1ρ imaging is a new quantitative MR imaging pulse sequence with the potential to discriminate between malignant and benign tissue. In this study, we evaluated the capability of T1ρ imaging to characterize tissue by applying T1ρ imaging to malignant and benign tissue in the nasopharynx and to normal tissue in the head and neck. MATERIALS AND METHODS: Participants with undifferentiated nasopharyngeal carcinoma and benign hyperplasia of the nasopharynx prospectively underwent T1ρ imaging. T1ρ measurements obtained from the histogram analysis for nasopharyngeal carcinoma in 43 participants were compared with those for benign hyperplasia and for normal tissue (brain, muscle, and parotid glands) in 41 participants using the Mann-Whitney U test. The area under the curve of significant T1ρ measurements was calculated and compared using receiver operating characteristic analysis and the Delong test, respectively. A P < . 05 indicated statistical significance. RESULTS: There were significant differences in T1ρ measurements between nasopharyngeal carcinoma and benign hyperplasia and between nasopharyngeal carcinoma and normal tissue (all, P < . 05). Compared with benign hyperplasia, nasopharyngeal carcinoma showed a lower T1ρ mean (62.14 versus 65.45 × ms), SD (12.60 versus 17.73 × ms), and skewness (0.61 versus 0.76) (all P < .05), but no difference in kurtosis (P = . 18). The T1ρ SD showed the highest area under the curve of 0.95 compared with the T1ρ mean (area under the curve = 0.72) and T1ρ skewness (area under the curve = 0.72) for discriminating nasopharyngeal carcinoma and benign hyperplasia (all, P < .05). CONCLUSIONS: Quantitative T1ρ imaging has the potential to discriminate malignant from benign and normal tissue in the head and neck.