6 July 2020 in Magnetic Resonance in Medicine
29 October 2020 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: T1ρ imaging is a new quantitative MR imaging pulse sequence with the potential to discriminate between malignant and benign tissue. In this study, we evaluated the capability of T1ρ imaging to characterize tissue by applying T1ρ imaging to malignant and benign tissue in the nasopharynx and to normal tissue in the head and neck. MATERIALS AND METHODS: Participants with undifferentiated nasopharyngeal carcinoma and benign hyperplasia of the nasopharynx prospectively underwent T1ρ imaging. T1ρ measurements obtained from the histogram analysis for nasopharyngeal carcinoma in 43 participants were compared with those for benign hyperplasia and for normal tissue (brain, muscle, and parotid glands) in 41 participants using the Mann-Whitney U test. The area under the curve of significant T1ρ measurements was calculated and compared using receiver operating characteristic analysis and the Delong test, respectively. A P < . 05 indicated statistical significance. RESULTS: There were significant differences in T1ρ measurements between nasopharyngeal carcinoma and benign hyperplasia and between nasopharyngeal carcinoma and normal tissue (all, P < . 05). Compared with benign hyperplasia, nasopharyngeal carcinoma showed a lower T1ρ mean (62.14 versus 65.45 × ms), SD (12.60 versus 17.73 × ms), and skewness (0.61 versus 0.76) (all P < .05), but no difference in kurtosis (P = . 18). The T1ρ SD showed the highest area under the curve of 0.95 compared with the T1ρ mean (area under the curve = 0.72) and T1ρ skewness (area under the curve = 0.72) for discriminating nasopharyngeal carcinoma and benign hyperplasia (all, P < .05). CONCLUSIONS: Quantitative T1ρ imaging has the potential to discriminate malignant from benign and normal tissue in the head and neck.
24 May 2022 in Magnetic Resonance in Medicine
5 August 2025 in Magnetic Resonance in Medicine
Purpose: Recent studies have shown that spin‐lock MRI can simplify quantitative magnetization transfer (MT) by eliminating its dependency on water pool parameters, removing the need for a T1 map in macromolecular proton fraction (MPF) quantification. However, its application is often limited by the requirement for long radiofrequency (RF) pulse durations, which are constrained by RF hardware capabilities despite remaining within specific absorption rate (SAR) safety limits.Methods: To address this challenge, we propose a novel method, MPF mapping using pulsed spin‐lock (MPF‐PSL). MPF‐PSL employs a pulsed spin‐lock train with intermittent free precession periods, enabling extended total spin‐lock durations without exceeding hardware and specific absorption rate limits. A comprehensive analytical framework was developed to model the magnetization dynamics of the two‐pool MT system under pulsed spin‐lock, demonstrating that MPF‐PSL achieves MT‐specific quantification while minimizing confounding effects from the water pool. The proposed method is validated with Bloch–McConnell simulations, phantoms, and in vivo studies at 3T.Results: Both Bloch–McConnell simulations and phantom validation demonstrated that MPF‐PSL exhibits insensitivity to water pool parameters while enabling robust MPF quantification. In vivo validation studies confirmed the method's clinical utility in detecting collagen deposition in patients with liver fibrosis.Conclusion: MPF‐PSL presents a practical solution for quantitative MT imaging, with strong potential for clinical applications.