Sadullah Uctasli

Prof. Dr. Sadullah Uctasli

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2013 in Journal of Dental Education
Verified
Journal Article
Closed access
PDF file
MAMuntaha Alhazmi
Muntaha Alhazmi
OEOmar El‐Mowafy
Omar El‐Mowafy
MZMohamed H. Zahran
Mohamed H. Zahran
SUSadullah Uctasli
Sadullah Uctasli
HAHassan Alkumru
Hassan Alkumru
KNKareem Nada
Kareem Nada

1 January 2020 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
EOEce İrem Oğuz
Ece İrem Oğuz
MÖMerve Erdoğ Özgür
Merve Erdoğ Özgür
SSSercan Sungur
Sercan Sungur
SUSadullah Uctasli
Sadullah Uctasli
Oğuz Eİ, et al. J Adv Prosthodont. 2020 Aug;12(4):197-203. https://doi.org/10.4047/jap.2020.12.4.197

7 January 2026 in Polymers
Verified
Journal Article
Open access
PDF file
IBIrem Buyukates
Irem Buyukates
Sufyan GaroushiSufyan Garoushi
Sufyan Garoushi
PVPekka Vallittu
Pekka Vallittu
SUSadullah Uctasli
Sadullah Uctasli
Lippo LassilaLippo Lassila
Lippo Lassila
The aim was to evaluate the shear-bond strength (SBS) of experimental short fiber-reinforced CAD/CAM composites (SFRC-CAD) and commercial CAD/CAM composites (Cerasmart 270) to different luting resin composites before and after hydrothermal aging. Discs (2 mm) obtained from SFRC-CAD and Cerasmart 270 were air-particle abraded and treated with a primer (G-CEM One Enhancing Primer) with or without universal adhesive (G2 Bond). A fiber-reinforced flowable composite (everX Flow) and a self-adhesive resin cement (G-CEM One) were used as luting materials under direct or indirect curing conditions. Thirty-two experimental groups were determined based on restorative material, bonding protocol, luting resin, curing technique, and aging procedure (n = 8/group). SBS was measured after 24 h of water storage or following hydrothermal aging. Data were analyzed using nonparametric statistical tests (p < 0.05). No statistically significant differences in SBS were observed between everX Flow and G-CEM One regardless of the bond application (p > 0.05). SFRC-CAD bonded with everX Flow and universal adhesive demonstrated significantly higher SBS than the corresponding Cerasmart groups (p < 0.05), whereas no significant differences were observed between comparable groups when G-CEM One was used. Failure mode analysis showed predominantly adhesive and mixed failures, with no cohesive failures within SFRC-CAD. Overall, the everX Flow proved to be an effective luting material, indicating that this material may be suitable for luting CAD/CAM indirect restorations.

24 July 2026 in Polymers
Verified
Journal Article
Open access
PDF file
NONazire Esra Ozer
Nazire Esra Ozer
ŞAŞahin Eren Akay
Şahin Eren Akay
EOEce İrem Oğuz
Ece İrem Oğuz
SUSadullah Uctasli
Sadullah Uctasli
Evaluating the shear bond strength (SBS) of contemporary universal adhesive systems on different substrates is critical for understanding their clinical applicability. In this study, the SBS of universal adhesives was assessed on 144 human and bovine tooth specimens, comparing enamel and dentin across etch-and-rinse and self-etch protocols. Following single-step or two-step adhesive application and resin cementation, the specimens were subjected to 5000 thermocycles before being evaluated with a universal testing machine. Failure modes and surface morphology were additionally characterized using stereomicroscopy and scanning electron microscopy (SEM). Statistical analyses revealed that both tissue type (p = 0.043) and tooth type (p < 0.001) significantly influenced SBS, while the main effect of the adhesive protocol was not significant (p = 0.485). A significant interaction occurred between tissue type and adhesive protocol (p = 0.013); Post hoc analyses revealed that Group A enamel had significantly higher bond strength than both Group D enamel (p = 0.026) and Group A dentin (p = 0.001). Observed failures were predominantly adhesive or mixed, and SEM confirmed expected acid-induced surface roughness. Human teeth yielded higher bond strengths than bovine teeth, meaning absolute SBS values from bovine lab studies should be used with caution.