Jean Pierre Uwiringiyimana

Dr. Jean Pierre Uwiringiyimana

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2022 in IEEE Access
Verified
Journal Article
Open access
Jean Pierre UwiringiyimanaJean Pierre Uwiringiyimana
Jean Pierre Uwiringiyimana
UKUmar Khayam
Umar Khayam
SSSuwarno Suwarno
Suwarno Suwarno
Gian Carlo MontanariGian Carlo Montanari
Gian Carlo Montanari
Partial discharges (PD) are the most common and harmful threat to the health of electrical insulation of high voltage (HV) and high field (HF) equipment. The occurrence of PD activity in HV and MV equipment is at the same time a cause and a sign of insulation degradation that may eventually result in the breakdown of the HV power equipment. For the safe and reliable operation of HV power equipment, continuous PD monitoring needs to be conducted conveniently to prevent any unplanned power outages and damage to electrical power equipment. The ultra-high frequency (UHF) PD measurement method has been widely used as an effective technique to detect PD activity on HV power equipment due to its non-invasive principle. To enable PD detection accuracy, there is still a need for more sensitive PD sensors that can assist the UHF PD monitoring system by suppressing ambient background noise and low-frequency electromagnetic interferences from telecommunication such as GSM signals. To tackle the sensitivity issues, this article presents a new design of ultra-wideband (UWB) microstrip patch antenna that is capable of effective suppression of low-frequency interference signals. The proposed antenna, designed, simulated, and optimized using the CST Microwave Studio software, has a bandwidth of 3.3GHz, below -10dB, in the operating frequency range of 1.2GHz-4.5GHz. The prototype of this antenna, printed on an FR4 substrate of a thickness of 1.6mm and a dielectric constant of 4.4, featuring a compact size of 100mm $\times100$ mm $\times1.6$ mm, was implemented to detect PD through laboratory experiments. This paper shows that the designed UWB antenna has high sensitivity, good noise rejection and it is, therefore, a promising candidate sensor for PD detection on HV equipment.

6 October 2022 in IEEE Access
Verified
Journal Article
Open access
Jean Pierre UwiringiyimanaJean Pierre Uwiringiyimana
Jean Pierre Uwiringiyimana
UKUmar Khayam
Umar Khayam
SSSuwarno Suwarno
Suwarno Suwarno
Gian Carlo MontanariGian Carlo Montanari
Gian Carlo Montanari
This article presents a design of ultra-high frequency (UHF), ultra-wide band (UWB) antenna used for partial discharge (PD) detection on high voltage and medium voltage power system equipment. The proposed UHF antenna has a working frequency band of 1.2GHz-4.5GHz, covering a total bandwidth of 3.3GHz with a return loss of less than -10dB in the entire antenna’s operating frequency. The computer simulation technology (CST) Microwave Studio software was used to design, simulate and optimize the proposed antenna. Upon simulation and optimization process, the antenna prototype was fabricated on the FR-4 substrate of 1.6 mm thickness and dielectric permittivity of 4.4. This antenna has a compact size of 100mm $\times100$ mm.The radiating patch and the ground plane of this antenna are made of annealed copper whose thickness is 0.035mm. The simulations and measurement results for the proposed antenna are in a good agreement, and the return loss of this antenna is less than −10dB with voltage standing wave ratio, VSWR, < 2 within the frequency range of interest. The proposed antenna performance in PD sensing is compared with a commercial high-frequency current transformer, HFCT. To validate the sensitivity performance of the designed antenna, experimental PD measurements were carried out by using an epoxy slab inserted between two parallel plates electrode model, in order to generate surface discharge on the insulator, and using a needle-plate electrode configuration to generate corona discharge in transformer oil. Based on PD measurement results, it was shown that the designed antenna has a high sensitivity, which make it a suitable candidate for UHF partial discharge monitoring on high voltage and medium voltage power assets.

13 September 2024 in IEEE Access
Verified
Journal Article
Open access
Jean Pierre UwiringiyimanaJean Pierre Uwiringiyimana
Jean Pierre Uwiringiyimana
UKUmar Khayam
Umar Khayam
SUSuwarno
Suwarno
Gian Carlo MontanariGian Carlo Montanari
Gian Carlo Montanari
Partial discharge (PD) occurrence in high-voltage (HV) and medium-voltage (MV) power assets is a warning sign of insulation system degradation or defective manufacturing/assembly, that may cause catastrophic damage and eventually lead to the breakdown of the power equipment. Ultra-high frequency (UHF) PD measurement technology has extensively been used to monitor insulation health of the HV or MV equipment due to its high immunity against ambient noise and conducted disturbances. This paper presents experimental validation of a new design of a UHF planar rectangular microstrip antenna that can be used for PD monitoring of HV and/or MV power equipment, such as power transformers. The designed planar rectangular microstrip antenna has a compact size of 80mmx70mmx1.6mm. Laboratory experiments were performed to validate the antenna sensitivity to PD activity caused by insulation defects created inside an oil-filled transformer tank model. PD measurement results confirm that the proposed rectangular microstrip antenna has high sensitivity and high signal-to-noise ratio (SNR), thanks to its capability to suppress external noise disturbances, especially during the online PD monitoring. Thus, the proposed UHF antenna seems to be a promising and alternative PD sensor that can be employed in UHF PD monitoring systems of HV or MV power equipment.

1 July 2019
Verified
Conference Paper
Closed access
Jean Pierre UwiringiyimanaJean Pierre Uwiringiyimana
Jean Pierre Uwiringiyimana
UKUmar Khayam
Umar Khayam
The measurement of partial discharge (PD) by detecting the released energy from the PD source in the form of electromagnetic wave during the corona discharge(discharge in air) by using Ultra-High Frequency (UHF) antenna has been an accurate diagnostic technique to determine the condition and quality of the insulation system in high voltage equipements. The UHF sensors have shown a great advantage in the detection of partial discharge because they are capable to detect partial discharge signal online without the need of prior shutdown of the high voltage apparatus. This paper discuss the measurement of partial discharge in air insulation by using the designed UHF double layer bowtie antenna with modified antenna wings edges. The double layer bowtie antenna was used to detect PD based on EM waves induced by PD in air insulation. The PD measurement results obtained by using the designed double layer bowtie were compared with PD measurements results obtained by using the RC detector which was taken as a comparison sensor. The characteristics of PD induced EM waves measured by RC detector and double layer bowtie have been investigated. The PD measurement was performed at three applied voltage levels namely, 5 kV, 6 kV and 7kV. The PD measurement results have shown that the higher applied voltage, the high Vpp magnitude for PD waveform, PD charge magnitude and PD number in both negative and positive half cycle.

13 November 2022
Verified
Conference Paper
Closed access
Jean Pierre UwiringiyimanaJean Pierre Uwiringiyimana
Jean Pierre Uwiringiyimana
UKUmar Khayam
Umar Khayam
SUSuwarno
Suwarno
This partial discharge measurement technique has been widely used as a powerful tool to assess the insulation condition of high voltage (HV) and medium voltage (MV) power equipment. UHF partial discharge (PD) detection method which applies UHF sensors has shown the capability to detect, localize and identify potential insulation defects. This paper presents a novel type of UHF microstrip patch antenna with an ultra-wideband frequency that was designed, manufactured, and implemented for PD detection in power transformer oil insulation. The proposed antenna was designed and simulated using the CST Microwave Studio Software. This antenna was printed on FR4 epoxy substrate whose thickness is 1.6mm and whose permittivity is 4.4. The copper material whose thickness is 0.035mm, was used on the radiating patch and ground plane of the antenna. The optimal design of the proposed antenna has a total bandwidth of 3.3GHz, under −10dB. The prototype of this antenna was fabricated and later on measured by using the vector network analyzer (VNA). After antenna fabrication, laboratory experiments were conducted to investigate the antenna's sensitivity performance in detecting PD activity in transformer oil insulation. The PD measurement results obtained by using the proposed antenna in comparison with the HFCT proved that the designed antenna has a high sensitivity to detect EM waves induced by PD activity in oil insulation, which makes it a promising sensor that can be used in the diagnosis of power transformer insulation based on UHF PD measurement technique.

1 May 2020 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
Jean Pierre UwiringiyimanaJean Pierre Uwiringiyimana
Jean Pierre Uwiringiyimana
UKU Khayam
U Khayam
The reliability of the power system cannot be achieved without good insulation quality of the high voltage apparatus. The Ultra-high frequency (UHF) method has been applied and proven to be accurate in detecting partial discharge (PD) signals emitted from the PD source in the form of electromagnetic waves. This paper discusses the design and application of double layer bowtie antenna and single layer bowtie antenna as UHF sensors for partial discharge detection in air insulation. The PD measurement results obtained by using the designed double layer bowtie antenna were compared with PD measurement results obtained by using the single layer bowtie antenna. The PD characteristics of induced EM waves detected by double layer bowtie antenna and single layer bowtie have been analysed. Based on the simulation results, the double layer bowtie antenna has a minimum return loss values of -31.54 dB and -33.43 dB, with corresponding resonance frequency values of 1.7 GHz and 2.7 GHz, with a total bandwidth of 602 MHz, and corresponding VSWR values of 1.04 and 1.05 while the measurement results by using Vector Network Analyser (VNA) shows that the designed double layer bowtie antenna has a minimum return loss of -20.2 dB, at a resonance frequency of 1.7 GHz, a bandwidth of 576 MHz and corresponding VSWR of 1.2. The single layer bowtie antenna has a bandwidth of 240 MHz, a minimum return loss of -24 dB, at a resonance frequency of 1.28 GHz, and a VSWR of 1.13 based on the simulation results while the single layer bowtie antenna has a bandwidth of 298 MHz, a minimum return loss of -23.32 dB, at a resonance frequency of 1.3 GHz, and a VSWR of 1.14 based on the measurement results by using VNA. The bowtie antennas were designed using the 3D-HFSS software with FR4-epoxy substrate type and later on were printed on the Printed Circuit Board (PCB). The PD measurement data were performed by using the applied voltage level of 7 kV. According to the antennas simulation results, antennas measurement results by VNA and PD measurement results, the double layer bowtie antenna has proven to be more sensitive than the single layer bowtie antenna.