In many commercial instruments for measuring reflectance, the area illuminated on the measured object is identical to the area from which light is collected. This configuration is suitable for strongly scattering materials such as paper, but issues arise with translucent materials, because a portion of the incident light spreads around the illuminated area by subsurface transport and escapes the detection system. This phenomenon, referred to as edge loss, yields erroneous, underestimated reflectance measurements. In the case of colored and opalescent materials, the impact of edge loss on the measured reflectance varies with the wavelength, which is a significant issue for spectrophotometer and colorimeter users. In the present study, we investigate the edge-loss phenomenon with an emphasis on human skin measurement. In particular, we use a mathematical model to estimate the PSF of translucent materials, relying on the diffusion approximation of the radiative transfer theory, to predict edge-loss measurement error. We use this model to discuss the suitability of several commercial spectrophotometers to accurately measure the translucent materials of various optical properties and show that not all devices can adapt to all translucent materials.
In recent years, there has been a growing interest in the measurements of the bidirectional reflectance distribution function (BRDF) in industry and research and development. However, there is currently no dedicated key comparison to demonstrate the scale conformity. To date, scale conformity has been proved only for classical in-plane geometries, in comparisons between different national metrology institutes (NMIs) and designated institutes (DIs). This study aims at expanding that with nonclassical geometries, including, for the first time, to the best of our knowledge, two out-of-plane geometries. A total of four NMIs and two DIs participated in a scale comparison of the BRDF measurements of three achromatic samples at 550 nm in five measurement geometries. The realization of the scale of BRDF is a well-understood procedure, as explained in this paper, but the comparison of the measured values presents slight inconsistencies in some geometries, most likely due to the underestimation of measurement uncertainties. This underestimation was revealed and indirectly quantified using the Mandel–Paule method, which provides the interlaboratory uncertainty. The results from the presented comparison allow the present state of the BRDF scale realization to be evaluated, not only for classical in-plane geometries, but also for out-of-plane geometries.
The bidirectional scattering-surface reflectance distribution function (BSSRDF) describes the radiance originated by the volume scattering and the surface reflectance of any position on the surface of a sample, when it is directionally irradiated at any other position. The present state of the technology for appearance rendering requires a more detailed physical description of translucent objects by traceable measurements of the BSSRDF. This work presents two primary facilities developed for traceable BSSRDF measurements by different measuring approaches. Their results on the same translucent samples have been compared and the achieved BSSRDF scale has been transferred to a commercial measuring system. This study highlights the problems of the different measuring instrument designs and provides the scientific community with more knowledge on the measurement of the BSSRDF, which will be crucial for future works on material appearance.
Translucent materials have the property of reflecting light beyond the illumination point due to subsurface light propagation in the material. These reflectance properties can be characterized using the bidirectional scattering-surface reflectance distribution function (BSSRDF), a radiometric quantity that is a function of spatial, angular, spectral, and polarization parameters. At very small scales, we have observed that Spectralon, a commercial material widely used as a diffuse reflectance calibration standard, can be regarded as translucent. This can generate measurement errors and limit Spectralon’s reliability as a calibration artefact for instruments that measure optical quantities on very small surfaces. To characterize the translucent properties of Spectralon, we have measured its BSSRDF using an experimental setup based on a goniospectrophotometer with a spatial scanning system for detection. In the present study, we show that Spectralon cannot be considered an opaque material at small scales (below 1 mm). For instrument measuring on small areas, Spectralon can be used for calibration only when the illumination area and the observation area differ by more than 1 mm in radius.
In recent years, a growing demand for the capability of performing accurate measurements of the bidirectional transmittance distribution function (BTDF) has been observed in industry, research and development, and aerospace applications. However, there exists no calibration and measurement capabilities-entry for BTDF in the database of the Bureau International des Poids et Mesures and to date no BTDF comparison has been conducted between different national metrology institutes (NMIs) or designated institutes (DIs). As a first step to a possible future key comparison and to test the existing capabilities of determining this measurand, two interlaboratory comparisons were performed. In comparison one, five samples of three different types of optical transmissive diffusers were measured by five NMIs and one DI. By specific sample choice, the focus for this study lay more on orientation-dependent scatter properties. In comparison two, where one NMI, one DI, one university, and three industrial partners investigated their measurement capabilities, the dependence on the orientation was not assessed, but two additional samples of the same material and different thickness were measured. Results of the two comparisons are presented, giving a good overview of existing experimental solutions, and showing specific sample-related problems to be solved for improved future BTDF measurements.