The accurate monitoring and dynamic analysis of metal ions are of considerable practical significance in environmental toxicology and life sciences. Colorimetric analysis and surface-enhanced Raman scattering (SERS) sensing technologies, utilizing the aggregation effect of gold and silver nanoparticles (Au/Ag NPs), have emerged as prominent methods for rapid metal ion detection. While sharing a common plasmonic basis, these two techniques serve distinct yet complementary analytical roles: colorimetric assays offer rapid, instrument-free visual screening ideal for point-of-care testing (POCT), whereas SERS provides superior sensitivity and structural fingerprinting for precise quantification in complex matrices. Furthermore, the synergistic integration of these modalities facilitates the development of dual-mode sensing platforms, enabling mutual signal verification for enhanced reliability. This article evaluates contemporary optical sensing methodologies utilizing aggregation effects and their advancements in the detection of diverse metal ions. It comprehensively outlines methodological advancements from nanomaterial fabrication to signal transduction, encompassing approaches such as biomass-mediated green synthesis and functionalization, targeted surface ligand engineering, digital readout systems utilizing intelligent algorithms, and multimodal synergistic sensing. Recent studies demonstrate that these techniques have attained trace-level identification of target ions regarding analytical efficacy, with detection limits generally conforming to or beyond applicable environmental and health safety regulations. Moreover, pertinent research has enhanced detection linear ranges, anti-interference properties, and adaptability for POCT, validating the usefulness and developmental prospects of this technology for analysis in complicated matrices.
The accurate monitoring and dynamic analysis of metal ions are of considerable practical significance in environmental toxicology and life sciences. Colorimetric analysis and surface-enhanced Raman scattering (SERS) sensing technologies, utilizing the aggregation effect of gold and silver nanoparticles (Au/Ag NPs), have emerged as prominent methods for rapid metal ion detection, serving as effective complements to conventional bulky instrumental analysis techniques. This is propelled by their distinctive localized surface plasmon resonance (LSPR) response and electromagnetic field enhancement mechanisms. This article evaluates contemporary optical sensing methodologies utilizing aggregation effects and their advancements in the detection of diverse metal ions. It comprehensively outlines methodological advancements from nanomaterial fabrication to signal transduction, encompassing approaches such as biomass-mediated green synthesis and functionalization, targeted surface ligand engineering, digital readout systems utilizing intelligent algorithms, and multimodal synergistic sensing. Recent studies demonstrate that these techniques have attained trace-level identification of target ions regarding analytical efficacy, with detection limits generally conforming to or beyond applicable environmental and health safety regulations. Moreover, pertinent research has enhanced detection linear ranges, anti-interference properties, and adaptability for point-of-care testing (POCT), validating the usefulness and developmental prospects of this technology for analysis in complicated matrices.
In polarization-modulated laser ranging systems, noise-induced waveform distortion and shifts in extremum position severely limit ranging accuracy. To address the difficulty of conventional filters in balancing noise suppression against preservation of extremum features, this paper proposes a local structure- and noise-aware spatially adaptive Stein’s Unbiased Risk Estimate (SURE) wavelet denoising method. Within the SURE minimum-mean-square-error framework, a local second-derivative structural feature and local noise are introduced to construct a spatially adaptive threshold-adjustment mechanism at individual wavelet coefficients. This mechanism reduces the shrinkage strength in extremum neighborhoods characterized by strong local second-order variation to protect key structural features, while enhancing shrinkage in relatively flat and noisy regions to improve denoising performance. Experimental results show that, relative to mean filtering, Savitzky–Golay (SG) filtering, and standard SURE wavelet denoising, the proposed method markedly improves the stability of extremum positions while maintaining the signal-to-noise ratio (SNR), and reduces the ranging root-mean-square error (RMSE) by 27.3 μm, 21.5 μm, and 4.0 μm on average across all tested distances, respectively. Extremum stability and ranging error exhibit a significant positive correlation (r = 0.863, = 0.745, p < 0.001), confirming the critical influence of extremum structural stability on ranging accuracy. This study is of value for extending precision measurement systems based on feature extraction.
Single-photon avalanche diodes (SPADs) operated in free-running mode exhibit three major nonideal effects: dead time, recovery time, and afterpulsing. Together, these effects cause the measured count rate to deviate from the true incident photon rate, degrade photon counting accuracy, and limit the linear dynamic range of the detector. Here, we establish a joint correction model for dead time, recovery time, and afterpulsing, based on a nonhomogeneous Poisson process, and propose a staged decoupling calibration strategy spanning from low to high count rates to systematically extract the afterpulse probability, dead time, and recovery-time constant. The proposed model is benchmarked on a commercial silicon SPAD module. Over a dynamic range of 550 kHz to 30 MHz, the mean absolute percentage error (MAPE) between model predictions and factory-provided correction factors is 2.74%, with a coefficient of determination (R2) of 0.985; relative deviations remain within 3% at low and moderate count rates. The proposed scheme requires only a continuous wave (CW) light source and a single channel TDC, eliminating the need for pulsed sources and external gated synchronization. It therefore provides a practical calibration route for commercial free-running silicon SPAD modules that require rapid on-site nonlinearity correction over a wide dynamic range. The demonstration and benchmark are performed on one commercial module, and extension to other low-afterpulse silicon SPADs is expected after local calibration and verification of the afterpulse-template separability conditions.