Background and Objectives: Three-dimensional (3D) coils offer stable initial framing in intracranial aneurysm embolization, but their utility in pulmonary and visceral vascular lesions has not been well established. The objective of this study was to assess the feasibility, safety, and effectiveness of 3D coils used as the primary framing device in pulmonary and visceral embolization. Materials and Methods: This retrospective study included 13 patients with 14 lesions, comprising seven pulmonary arteriovenous malformations (PAVMs), six splenic artery aneurysms (SAAs), and one hepatic artery pseudoaneurysm (HAP), treated between 2024 and 2025. In all lesions, a 0.018-inch 3D coil was deployed as the initial framing coil, followed by further packing with additional 3D or non-3D coils. Technical success, angiographic success, and clinical outcomes were evaluated. Results: Technical success was achieved in all lesions (14/14, 100%; 95% CI, 78.5–100). Angiographic success was achieved in 13 of 14 lesions (92.9%; 95% CI, 68.5–98.7), and clinical success was achieved in 12 of 13 lesions (92.3%; 95% CI, 66.7–98.6). Post-embolization syndrome (PES) developed in five patients with SAAs and in one patient with HAP; all complications were minor and resolved with conservative management. No coil migration or major complications occurred. Conclusions: When used as the initial framing device, 3D coils were technically feasible and achieved acceptable short-term angiographic and clinical outcomes in this small, heterogeneous series; these preliminary findings require confirmation in comparative studies.
Background: Loculated pleural effusion—characterized by fibrinous septations that compartmentalize the pleural space and impede drainage—is a technically demanding indication for percutaneous catheter drainage (PCD), in which accurate catheter placement directly determines drainage success. Whether fluoroscopic guidance reduces reintervention compared with ultrasound guidance alone in this population is unknown. Methods: We conducted a retrospective cohort study of 190 PCD procedures for loculated pleural effusion at a single tertiary-care center (Samsung Changwon Hospital, Changwon, South Korea; 118 ultrasound-guided [US alone], median age 71 years; 72 combined ultrasound-and-fluoroscopy-guided [US + Fluoroscopy], median age 75 years). Underlying etiologies included parapneumonic effusion, empyema, malignant effusion, and other causes. The primary outcome was any reintervention. Between-group comparisons used the Mann–Whitney U and Fisher’s exact tests; adjusted analyses included multivariable logistic regression, 1:1 propensity score matching (PSM), and Cox proportional hazards modeling. Results: Reintervention occurred in 35.6% of US alone versus 18.1% of US + Fluoroscopy procedures (relative risk 0.51, 95% CI 0.29–0.88; p = 0.013). After adjustment, US + Fluoroscopy was associated with lower odds of reintervention (adjusted OR 0.42, 95% CI 0.17–0.95; p = 0.043). PSM (60 matched pairs) confirmed this finding (35.0% vs. 16.7%; McNemar’s p = 0.046). The Cox model showed a directionally consistent association (adjusted HR 0.50, 95% CI 0.25–1.02; p = 0.056; log-rank p = 0.012). Conclusions: Combined ultrasound-and-fluoroscopy guidance was associated with a significantly lower reintervention rate than ultrasound guidance alone, with consistent direction of effect across unadjusted and adjusted analyses. These findings support fluoroscopy as an adjunct modality for this technically demanding indication.
Background/Objectives: Isolated internal iliac artery aneurysm (IIAA) is rare and carries a high mortality when ruptured. Management is particularly challenging in very elderly, anticoagulated patients in whom open repair may carry substantial perioperative risk. Herein, we report a case that illustrates device selection when a marked common iliac–external iliac size discrepancy precludes bridging with the available iliac limbs. Case Presentation: A 98-year-old man receiving apixaban presented with lower abdominal pain, nausea, and diarrhea. Computed tomography demonstrated a ruptured right IIAA measuring 79 × 72 mm in the axial plane, with retroperitoneal hematoma. A marked size discrepancy between the common iliac artery (20 mm) and external iliac artery (approximately 10 mm), together with vessel tortuosity, made common iliac–external iliac bridging with an iliac limb unsuitable with the devices available. Emergency endovascular aneurysm repair with a full aortic bifurcated endograft was combined with coil embolization of the inferior gluteal artery and gelatin sponge embolization of the sac. The contralateral internal iliac artery, which harbored a 31 mm aneurysm, was preserved. A suspected type IV endoleak had resolved on CT at day 4, and the patient was discharged on postoperative day 8 without complications. At 6-month follow-up, the aneurysm sac had decreased from 79 × 72 mm to 72 × 62 mm in the axial plane with no evidence of endoleak, and he remained ambulatory without pelvic ischemic symptoms. Conclusions: A full aortic bifurcated endograft combined with coil and sac embolization may be a feasible bail-out option when a marked common iliac–external iliac size discrepancy precludes bridging with the available iliac limbs, even in a nonagenarian receiving apixaban.
Background: Frontier text-to-image models can synthesise radiologic images of high realism, raising the question of whether expert radiologists can serve as a provenance safeguard for the medical image record. Methods: We conducted a prospective, pre-registered visual Turing test in which 60 invited Korean board-certified radiology faculty and trainees judged authentic (teaching-repository) and AI-generated radiologic images from a locked pool of 241 displayable cells (82 entities; nine subspecialties; six modalities; 60 readers x 60 trials = 3,600 reader–image observations) produced by two contemporary commercial generators. The primary endpoint was the confidence-weighted, reader-averaged multi-reader multi-case area under the curve for AI versus authentic images, conditional on the locked image pool; the key secondary endpoint was the Faculty-minus-Junior difference under a two one-sided tests equivalence framework. The pre-specified statistical analysis plan was registered on the Open Science Framework before data lock. Findings: All 60 readers completed the test. The pooled confidence-weighted area under the curve was 0.71 (95% CI, 0.69 to 0.74), above the null value of 0.5 but within the pre-specified modest tier (0.60 to 0.75). The Faculty-minus-Junior contrast was 0.04 (95% CI, −0.02 to 0.10), including zero, and the two one-sided tests established equivalence within the +/−0.10 margin. No reader stratum and no pre-specified sensitivity analysis reached the deployable-classifier threshold (area under the curve >= 0.75). Interpretation: In this single-country cohort, expert radiologists distinguished frontier-generated from authentic radiologic images only modestly, without a meaningful expertise gradient (equivalence within +/−0.10) and with no reader stratum reaching a standalone provenance safeguard. These findings support radiology AI-literacy training and pipeline-level provenance safeguards rather than reliance on reader judgment, and warrant retesting in an independent reader cohort. Funding: This research was supported by a grant of the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea (grant number: RS-2025-02213531).
Background: Chest X-ray (CXR) foundation models can predict patient demographic categories (sex, age, race) from images alone by linear probing, but whether encoded attributes drive finding prediction has not been tested at scale. Methods: On MIMIC-CXR (230,697 images, 60,518 patients), we measured attribute dependence (AUROC drop after residualizing an attribute from a frozen embedding) across 24 patient attributes (four demographics and 20 ICD-coded comorbidities), 10 thoracic findings, and 6 overlap-free foundation models ( triplets), with 3 additional CXR-pretrained models (RAD-DINO, CheXzero, CheSS) for encoding and fairness analyses. Dependence was regressed on attribute-finding odds ratios (ORs), encoding strength, and model-level factors. Results: Encoding and dependence dissociated. Sex (AUROC 0.942) contributed ; race (0.83) contributed (rank 14/24); heart failure (0.774) showed the largest dependence (). explained 50.6% of dependence variance (, ); model factors added no detectable contribution (, ). Residualizing the top three high-OR attributes reduced AUROC by 0.026 without narrowing sex or age subgroup gaps (minimum detectable effect size (MDES) = 0.0019). Across 9 models, four-category race subgroup gaps (mean 0.069) were 30–75× larger than race residualization drops (mean 0.0015); CheXzero showed the same decoupling. Conclusions: Encoding, residualization-sensitive dependence, and subgroup bias are three separable quantities on the same model. Pre-deployment audits on inpatient-skewed cohorts can prioritize attributes by local OR; jointly residualizing race and its cardiac correlates does not narrow the race subgroup gap, which instead tracks group-wise finding base rates. Cross-institutional transfer remains open: no public CXR cohort currently links comorbidity electronic health records for external validation of the OR-dependence relationship.