Background and Objectives: Three-dimensional (3D) coils offer stable initial framing in intracranial aneurysm embolization, but their utility in pulmonary and visceral vascular lesions has not been well established. The objective of this study was to assess the feasibility, safety, and effectiveness of 3D coils used as the primary framing device in pulmonary and visceral embolization. Materials and Methods: This retrospective study included 13 patients with 14 lesions, comprising seven pulmonary arteriovenous malformations (PAVMs), six splenic artery aneurysms (SAAs), and one hepatic artery pseudoaneurysm (HAP), treated between 2024 and 2025. In all lesions, a 0.018-inch 3D coil was deployed as the initial framing coil, followed by further packing with additional 3D or non-3D coils. Technical success, angiographic success, and clinical outcomes were evaluated. Results: Technical success was achieved in all lesions (14/14, 100%; 95% CI, 78.5–100). Angiographic success was achieved in 13 of 14 lesions (92.9%; 95% CI, 68.5–98.7), and clinical success was achieved in 12 of 13 lesions (92.3%; 95% CI, 66.7–98.6). Post-embolization syndrome (PES) developed in five patients with SAAs and in one patient with HAP; all complications were minor and resolved with conservative management. No coil migration or major complications occurred. Conclusions: When used as the initial framing device, 3D coils were technically feasible and achieved acceptable short-term angiographic and clinical outcomes in this small, heterogeneous series; these preliminary findings require confirmation in comparative studies.
Background/Objectives: May–Thurner syndrome (MTS) is a common cause of iliofemoral deep vein thrombosis (DVT). Venous bleeding associated with MTS is extremely rare and has been reported mainly as spontaneous iliac vein rupture (SIVR) with retroperitoneal or iliac hematoma. Additionally, standardized treatment strategies have not yet been established. Herein, we report a case of an iliac hematoma associated with MTS that was successfully treated with endovascular mechanical thrombectomy and bare-metal stenting. Case Presentation: A 69-year-old man presented with acute swelling and pain in the left lower extremity. Computed tomography angiography demonstrated extensive iliofemoral DVT and an iliac hematoma adjacent to the left common iliac vessels, without definite evidence of iliac vein rupture. Initial conservative management with anticoagulation therapy was selected as the patient was hemodynamically stable and showed no active bleeding. However, follow-up imaging one week later revealed persistent DVT with interval enlargement of the hematoma. Pelvic arteriography excluded an arterial bleeding source. Endovascular treatment was performed, including mechanical thrombectomy using the AngioJet system and bare-metal stent placement to restore venous outflow. Follow-up imaging revealed complete thrombus resolution, hematoma regression, and sustained stent patency. Conclusions: Iliac hematomas associated with MTS may occur without definite radiological evidence of iliac vein rupture. In selected hemodynamically stable patients, an individualized endovascular strategy focused on venous outflow restoration using the AngioJet system and bare metal stents may be a feasible treatment option.
Background: Frontier text-to-image models can synthesise radiologic images of high realism, raising the question of whether expert radiologists can serve as a provenance safeguard for the medical image record. Methods: We conducted a prospective, pre-registered visual Turing test in which 60 invited Korean board-certified radiology faculty and trainees judged authentic (teaching-repository) and AI-generated radiologic images from a locked pool of 241 displayable cells (82 entities; nine subspecialties; six modalities; 60 readers x 60 trials = 3,600 reader–image observations) produced by two contemporary commercial generators. The primary endpoint was the confidence-weighted, reader-averaged multi-reader multi-case area under the curve for AI versus authentic images, conditional on the locked image pool; the key secondary endpoint was the Faculty-minus-Junior difference under a two one-sided tests equivalence framework. The pre-specified statistical analysis plan was registered on the Open Science Framework before data lock. Findings: All 60 readers completed the test. The pooled confidence-weighted area under the curve was 0.71 (95% CI, 0.69 to 0.74), above the null value of 0.5 but within the pre-specified modest tier (0.60 to 0.75). The Faculty-minus-Junior contrast was 0.04 (95% CI, −0.02 to 0.10), including zero, and the two one-sided tests established equivalence within the +/−0.10 margin. No reader stratum and no pre-specified sensitivity analysis reached the deployable-classifier threshold (area under the curve >= 0.75). Interpretation: In this single-country cohort, expert radiologists distinguished frontier-generated from authentic radiologic images only modestly, without a meaningful expertise gradient (equivalence within +/−0.10) and with no reader stratum reaching a standalone provenance safeguard. These findings support radiology AI-literacy training and pipeline-level provenance safeguards rather than reliance on reader judgment, and warrant retesting in an independent reader cohort. Funding: This research was supported by a grant of the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea (grant number: RS-2025-02213531).
Background: Chest X-ray (CXR) foundation models can predict patient demographic categories (sex, age, race) from images alone by linear probing, but whether encoded attributes drive finding prediction has not been tested at scale. Methods: On MIMIC-CXR (230,697 images, 60,518 patients), we measured attribute dependence (AUROC drop after residualizing an attribute from a frozen embedding) across 24 patient attributes (four demographics and 20 ICD-coded comorbidities), 10 thoracic findings, and 6 overlap-free foundation models ( triplets), with 3 additional CXR-pretrained models (RAD-DINO, CheXzero, CheSS) for encoding and fairness analyses. Dependence was regressed on attribute-finding odds ratios (ORs), encoding strength, and model-level factors. Results: Encoding and dependence dissociated. Sex (AUROC 0.942) contributed ; race (0.83) contributed (rank 14/24); heart failure (0.774) showed the largest dependence (). explained 50.6% of dependence variance (, ); model factors added no detectable contribution (, ). Residualizing the top three high-OR attributes reduced AUROC by 0.026 without narrowing sex or age subgroup gaps (minimum detectable effect size (MDES) = 0.0019). Across 9 models, four-category race subgroup gaps (mean 0.069) were 30–75× larger than race residualization drops (mean 0.0015); CheXzero showed the same decoupling. Conclusions: Encoding, residualization-sensitive dependence, and subgroup bias are three separable quantities on the same model. Pre-deployment audits on inpatient-skewed cohorts can prioritize attributes by local OR; jointly residualizing race and its cardiac correlates does not narrow the race subgroup gap, which instead tracks group-wise finding base rates. Cross-institutional transfer remains open: no public CXR cohort currently links comorbidity electronic health records for external validation of the OR-dependence relationship.