In the modern power grid, characterized by the increased penetration of power electronics and extensive utilization of renewable energy, inverter-based power plants play a pivotal role as the principal interface of renewable energy sources (RESs) and the grid. Considering the stability characteristics of grid-following (GFL) inverters when the grid is relatively weak, the application of grid-forming (GFM) controls becomes imperative in enhancing the stability of the entire power plant. Thus, there is an urgent need for suitable and effective models to study the interaction and stability of the paralleled inverters employing GFL and GFM controls. Thus, the small-signal modeling with full-order state-space model and eigenvalues analysis are presented in this paper. First, the small-signal state-space model of the individual GFL and GFM inverters is obtained, considering the control loop, interaction, reference frame, transmissions, and time delays. Then, the models of the individual inverter are extended to the hybrid inverters to study the effects of the GFM inverters on the small-signal stability of the entire system. And the impacts of the inertia and damping are analyzed by the eigenvalues of the state-transition matrix. A case comprising three parallel GFL inverters and two GFL inverters with one GFM inverter, respectively, are studied to examine the effectiveness and accuracy of the model. Finally, the stability margin obtained from the eigenvalue analysis of the entire system is verified by time-domain simulations.
With the rapid development of renewable energy sources such as wind power and photovoltaics, the penetration rate of power electronic equipment represented by grid-forming (GFM) and grid-following (GFL) converters in the power system has been increasing. The development of modern power systems is gradually showing a trend of high proportion of renewable energy and high proportion of power electronic devices (double-high), which profoundly changes the dynamic characteristics of modern power systems. Most of the converters in the power system adopt the GFL control strategy, which lacks the ability to support frequency and voltage. The converter with GFM control have gradually been incorporated into high-proportion renewable energy systems due to their voltage support and inertial response capabilities. However, the proportion configurations of GFM converter in the GFM/GFL hybrid system still needs to be further investigated. Therefore, this paper compares the basic principles and control methods of converters based on GFM strategy and GFL strategy, establishes the small-signal model of 100% REI system, and comparatively analyzes the dynamic characteristics of GFM and GFL converters. Secondly, a proportional configuration method for the GFM converter in 100% renewable electricity independent system (100% REI system) is proposed, and then through the small-signal model, the influence of different proportions of GFM converters and control mode on the stability of 100% REI system is discussed, the minimum configuration proportion of GFM converter to satisfy the stable operation of the system is explored. Finally, the correctness of the proportional configuration of GFM converters proposed in this paper and the engineering feasibility of independent operation of 100% REI system is verified.
19 April 2023 in International Transactions on Electrical Energy Systems
With the establishment and rapid development of the national carbon emission trading market, new energy system participates in the carbon emission trading market. Analysing the potentiality of virtual power plant trading in carbon emission trading market, this paper designs a two-stage joint trading mechanism for electricity and carbon market with a weekly cycle according to their characteristics, which contain multiple transaction types for both markets. In addition, this paper introduces a carbon capture system (CCS) in gas turbine, which reduces the actual carbon emissions and increases the carbon market income of virtual power plant. Furthermore, it improves the comprehensive and flexible operation capability by adjusting the operation level of CCS, which is conducive to the timely consumption of renewable energy. Aiming at the uncertainty of renewable energy output and electricity price, the paper adopts a multiscenario analysis method to deal with it and establishes a stochastic optimization model to maximize joint earnings. Finally, through example analysis with GAMS, the effectiveness of the scheduling model is verified with simulation results. The overall income of the virtual power plant is improved, and the low carbon power is realized.
The demand for decarbonization calls for building up a nearly 100% renewable electricity resulting in Grid-forming (GFM) capability requirements. The foregoing paradigm shifts from synchronous AC systems to converter-based systems that need to remain stable and self-synchronous while providing GFM services. However, as this article’s analysis in the introduction, achieving such goals inevitably necessitates the implementation of a PLL controller and energy storage in a wind turbine, whereas it is not suitable to operate in a weak energy system. To tackle this issue, a novel grid-forming method is proposed. The suggested idea calls for creating a DC voltage controller in a grid-side converter that mimics inertia response and applying a Rotor kinetic energy storage (RKES) controller in a Generator-side converter. Moreover, a coordinated controller of RKES controllers and conventional low voltage ride-through (LVRT) is proposed to gain increases in dynamic performance and maintain grid-forming capabilities in the transient process. Extensive modeling, experimental results based on a semi-physical platform, and an actual wind farm demonstration project are provided to validate the proposed controls. The results demonstrate the effectiveness of the presented method when applied to the future 100% renewable electricity.
Existing short-circuit calculation methods for distribution networks with renewable energy sources ignore the fluctuation of renewable sources and cannot reflect the impact of renewable sources and load changes on short-circuit current in real time at all times of the day and in extreme scenarios. A real-time short-circuit current calculation method is proposed to take into account the stochastic nature of distributed generators (DGs) and electricity loads. Firstly, the continuous power flow of distribution networks is calculated based on the real-time renewable energy output and electricity loads. And then, equivalent DG models with low-voltage ride through (LVRT) strategies are substituted into the iterative calculation method to obtain the short-circuit currents of all main branches in real time. The effects of different renewable energy output curves on distribution network short-circuit currents are quantitatively analyzed during the fluctuation in distributed power output, which can provide an important basis for the setting calculation of distribution network relay protection and the study of new principles of protection.
In some areas, such as Gansu in China and Texas in the USA, lots of wind power bases are located far away from load centers. Transmitting large amounts of wind power to load centers through long transmission lines will lead to wind turbines being integrated into a weak grid, which decreases the stability limits of wind turbines. To solve this problem, this study investigates the stability limits of a Doubly Fed Induction Generator (DFIG) connected to a weak grid in a DC-link voltage control timescale. To start with, a model of the DFIG in a DC-link voltage control timescale is presented for stability limit analysis, which facilitates profound physical understanding. Through steady-state stability analysis based on sensitivity evaluation, it is found that the critical factor restricting the stability limit of the DFIG connected to a weak grid is ∂Pe/∂ (−ird), changing from positive to negative. As ∂Pe/∂ (−ird) reaches zero, the system reaches its stability limit. Furthermore, by considering control loop dynamics and grid strength, the stability limit of the DFIG is investigated based on eigenvalue analysis with multiple physical scenarios. The results of root locus analysis show that, when the DFIG is connected to an extremely weak grid, reducing the bandwidth of the PLL or increasing the bandwidth of the AVC with equal damping can increase the stability limit. The aforesaid theoretical analysis is verified through both time domain simulation and physical experiments.