During non-severe fault conditions, crowbar protection is not activated and the rotor windings of a doubly-fed induction generator (DFIG) are excited by the AC/DC/AC converter. Meanwhile, under asymmetrical fault conditions, the electrical variables oscillate at twice the grid frequency in synchronous dq frame. In the engineering practice, notch filters are usually used to extract the positive and negative sequence components. In these cases, the dynamic response of a rotor-side converter (RSC) and the notch filters have a large influence on the fault current characteristics of the DFIG. In this paper, the influence of the notch filters on the proportional integral (PI) parameters is discussed and the simplified calculation models of the rotor current are established. Then, the dynamic performance of the stator flux linkage under asymmetrical fault conditions is also analyzed. Based on this, the fault characteristics of the stator current under asymmetrical fault conditions are studied and the corresponding analytical expressions of the stator fault current are obtained. Finally, digital simulation results validate the analytical results. The research results are helpful to meet the requirements of a practical short-circuit calculation and the construction of a relaying protection system for the power grid with penetration of DFIGs.
28 September 2023 in IEEE Transactions on Smart Grid
With the high penetration connection of inverter-interfaced distributed generators and the increasing application of large-capacity energy routers, fully weak-infeed distribution networks consisting entirely of power-electronized weak-infeed power sources are set to become one of the fundamental forms of future distribution networks. For fully weak-infeed distribution networks, multi-terminal current differential protection is considered an optional or even preferred line protection scheme. In this paper, a multi-terminal current differential protection setting method for fully weak-infeed distribution networks is proposed based on the restricted enumeration method. To address the impact of data synchronization errors and measurement errors of multi-terminal current on differential current, the problem of determining the maximum differential current superimposed with the multi-terminal current phasor errors is transformed into a high-dimensional non-convex optimization problem. The distribution law of the global optimal solution in the non-convex constraint space is deeply studied and analyzed, and a restricted enumeration method is proposed that can quickly solve the protection setting value, thereby solving the problem of multi-terminal current differential protection setting. The accuracy and rapidity of the proposed method are verified by comparing the calculation accuracy and time consumption of the restricted enumeration method and the exhaustive search. It is shown that the proposed multi-terminal differential protection setting method exhibits sufficient reliability and sensitivity in fully weak-infeed distribution networks, as verified through simulation analysis using a fully weak-infeed distribution network model built in PSCAD/EMTDC.
20 November 2019 in IEEJ Transactions on Electrical and Electronic Engineering
The abnormal grid voltages, such as sags, swells, and harmonics caused by grid faults, seriously threaten the safe operation of a doubly-fed induction generator (DFIG)-based wind energy conversion system (WECS). To enhance the fault ride-through (FRT) capability of DFIG and improve the converter capacity utilization, this paper proposes a novel DFIG-based WECS using a dynamic reconfiguration hybrid interlinking transformer (DR-HIT) technique for performance improvement under grid faults. Multiple operating modes and flexible switching strategies were developed based on the analysis of the proposed topology and principles. The proposed DR-HIT approach smooths the DFIG ’s output power fluctuations through the cooperative control of the multifunctional converter (MFC) and grid-side converter (GSC) in shunt mode when the grid voltage is stable. Upon the occurrence of a grid voltage fault, the DR-HIT flexibly switches from shunt mode to series mode, maintaining the terminal voltage at a constant value. Additionally, once grid voltage recovers, the DR-HIT reverts flexibly to its shunt mode. Finally, simulations and experimental results demonstrate that the proposed scheme can achieve accurate control of the system and flexible switching between different modes.
19 April 2023 in International Transactions on Electrical Energy Systems
With the establishment and rapid development of the national carbon emission trading market, new energy system participates in the carbon emission trading market. Analysing the potentiality of virtual power plant trading in carbon emission trading market, this paper designs a two-stage joint trading mechanism for electricity and carbon market with a weekly cycle according to their characteristics, which contain multiple transaction types for both markets. In addition, this paper introduces a carbon capture system (CCS) in gas turbine, which reduces the actual carbon emissions and increases the carbon market income of virtual power plant. Furthermore, it improves the comprehensive and flexible operation capability by adjusting the operation level of CCS, which is conducive to the timely consumption of renewable energy. Aiming at the uncertainty of renewable energy output and electricity price, the paper adopts a multiscenario analysis method to deal with it and establishes a stochastic optimization model to maximize joint earnings. Finally, through example analysis with GAMS, the effectiveness of the scheduling model is verified with simulation results. The overall income of the virtual power plant is improved, and the low carbon power is realized.
1 March 2022 in IET Generation, Transmission & Distribution
In a high proportion of new energy grids or a 100% new energy source of power grid, the dynamic performance of PMSG under fault conditions is very important. However, the current small signal model lacks detailed and deep analysis of a permanent‐magnet synchronous generator (PMSG)‐based wind power generation under LVRT control. Here, a small signal model of a PMSG under pre‐fault, fault and after fault failure recovery stages are established. This paper employs linear analyses to characterize the dynamic performance of a PMSG‐based wind power generation system under LVRT control and practical generator characteristics. In particular, the conflict between frequency regulation and LVRT is discussed based on the constructed model. On this basis, the impact of dc‐link bandwidth on the system performance during failure recovery stage is discussed, and the active damping method is analysed to improve the performance of PMSG during failure and failure recovery stages. Finally, time‐domain simulations are utilized to verify the analyses and models discussed. The research results in this paper are helpful to promote and improve the performance of PMSG during LVRT conditions.