LUIS HUMBERTO RODRIGUEZ ALFARO

LUIS HUMBERTO RODRIGUEZ ALFARO

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
LGLuis Alonso Trujillo Guajardo
Luis Alonso Trujillo Guajardo
Miguel A. Platas-GarzaMiguel A. Platas-Garza
Miguel A. Platas-Garza
JRJohnny Rodríguez-Maldonado
Johnny Rodríguez-Maldonado
MGMario Gonzalez
Mario Gonzalez
LALUIS HUMBERTO RODRIGUEZ ALFARO
LUIS HUMBERTO RODRIGUEZ ALFARO
FSFernando Salinas Salinas
Fernando Salinas Salinas
This article presents an evaluation of Prony method and its implementation considerations for motor current signal analysis diagnostics in rotor cage induction motors. The broken rotor bar fault signature in current signals is evaluated using Prony method, where its advantages in comparison with fast Fourier transform are presented. The broken rotor bar fault signature could occur during the life cycle operation of induction motors, so that is why an effective early detection estimation technique of this fault could prevent an insulation failure or heavy damage, leaving the motor out of service. First, an overview of cage winding defects in rotor cage induction motors is presented. Next, Prony method and its considerations for the implementation in current signature analysis are described. Then, the performance of Prony method using numerical simulations is evaluated. Lastly, an assessment of Prony method as a tool for current signal analysis diagnostics is performed using a laboratory test system where real signals of an induction motor with broken rotor bar operated with/without a variable frequency drive are analyzed. The summary results of the estimation (amplitudes and frequencies) are presented in the results and discussion section.

6 February 2023 in Machines
Verified
Journal Article
Open access
PDF file
LGLuis Alonso Trujillo Guajardo
Luis Alonso Trujillo Guajardo
LALUIS HUMBERTO RODRIGUEZ ALFARO
LUIS HUMBERTO RODRIGUEZ ALFARO
JRJohnny Rodríguez-Maldonado
Johnny Rodríguez-Maldonado
MGMario Gonzalez
Mario Gonzalez
FSFernando Salinas Salinas
Fernando Salinas Salinas
MSMeng Yen Shih
Meng Yen Shih
This article presents an evaluation of Prony method estimation and its implementation considerations for surge comparison test application in turn insulation diagnostics for three-phase stator windings. Surge testing diagnostics compares recorded surge voltage signals of motor winding, and a diagnostic is then defined with a defined value of EAR (error area ratio), which evaluates the difference between signals to determine a turn insulation diagnostic. First, an overview of surge testing is presented. Next, the Prony method and the considerations for its implementation in surge testing are described. Then, a numerical simulation is used to define a simulated turn fault surge voltage signal, where its parameters can be obtained with Prony method estimation and compared with EAR to evaluate its performance. Lastly, recorded surge test signals from two tested motors are used to validate Prony method estimation application for surge test diagnostics, where twelve recorded surge signals for no-fault and fault conditions were analyzed. The summary results of the surge signals parameter estimation are presented in the results and discussion section.

2 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
IRIván Rafael Macías Ruiz
Iván Rafael Macías Ruiz
LGLuis Alonso Trujillo Guajardo
Luis Alonso Trujillo Guajardo
LALUIS HUMBERTO RODRIGUEZ ALFARO
LUIS HUMBERTO RODRIGUEZ ALFARO
FSFernando Salinas Salinas
Fernando Salinas Salinas
JRJohnny Rodríguez-Maldonado
Johnny Rodríguez-Maldonado
MGMario Gonzalez
Mario Gonzalez
This article presents a comparative analysis for the design considerations for a solar power generation transformer. One of the main existing problems in transformer manufacturing is in the renewable energy field, specifically the solar power generation, where the transformer connected to the inverter is operated under a certain harmonic content and operating conditions. The operating conditions of the transformer connected to the inverter are particularly unknown for each solar power plant; thus, the transformer will be subject to a particular harmonic content, which is defined by the inverter of the solar power plant. First, the fundamental calculations for solar power plant transformer and the proposed methodology for the design calculation of the distribution pad-mounted three phase transformer are presented. Then, a design study case is described where a distribution transformer and an inverter of a particular solar power plant are used for the analysis. Next, the transformer under analysis is modeled using finite element analysis in ANSYS Maxwell® software, where the transformer will be designed for a non-harmonic and harmonic content application. Lastly, the main design parameters, flux density, the core losses and the winding excitation voltage of the transformer are calculated and presented in results and discussion section.

1 October 2013
Verified
Conference Paper
Closed access
PAP. Acosta-Santana
P. Acosta-Santana
LALUIS HUMBERTO RODRIGUEZ ALFARO
LUIS HUMBERTO RODRIGUEZ ALFARO
Efrain AlcortaEfrain Alcorta
Efrain Alcorta
Fault tolerant control (FTC) seeks to avoid the deterioration of the system at the time that there is a change of one or more parameters outside the limits of tolerance. There is in the literature a set of approaches based on the idea of tracking the nominal trajectory, which have been proved to be effective. However, some of them do not maintain the nominal controller, others, even if they keep it, require meet very demanding existence conditions. This paper proposes a fault recovery using a cascade control structure. The proposed design is based on the nominal trajectory tracking as well, but keeps intact the original control while existence conditions are relaxed. The resulting equivalent controller can be changed according to the performance needs of the system's response to faults. The controller could be defined by using stability regions and LMI tools.

20 November 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JRJohnny Rodríguez-Maldonado
Johnny Rodríguez-Maldonado
LGLuis Alonso Trujillo Guajardo
Luis Alonso Trujillo Guajardo
LALUIS HUMBERTO RODRIGUEZ ALFARO
LUIS HUMBERTO RODRIGUEZ ALFARO
FSFernando Salinas Salinas
Fernando Salinas Salinas
MGMario Gonzalez
Mario Gonzalez
Miguel A. Platas-GarzaMiguel A. Platas-Garza
Miguel A. Platas-Garza
Synchrophasor measurements are used as a tool to obtain information from an electrical network to make control decisions. The electrical grid is susceptible to many changes due to faults, lightning discharges, switching surges, transformer energization, back-to-back switching of capacitor banks, and so on. Hence, the phasor takes different shapes under several operating conditions of the electrical grid. Therefore, phasor estimation should consider changes in the waveform. In this article, a proposed methodology based on deterministic state observers is presented, where transients and modulation changes in the analyzed signals are considered during phasor measurement. This approach aims to provide competitive estimations using a simplified algorithm compared to Kalman phasor estimation techniques. To evaluate the proposed technique, the requirements of standard IEC/IEEE 60255-118-1 for protection relay applications and analytic measurements are studied.

30 January 2023 in Ingenierias
Verified
Journal Article
Open access
PDF file
Efrain AlcortaEfrain Alcorta
Efrain Alcorta
DRDavid Alejandro Díaz Romero
David Alejandro Díaz Romero
RMRodolfo Castillo Martínez
Rodolfo Castillo Martínez
LALUIS HUMBERTO RODRIGUEZ ALFARO
LUIS HUMBERTO RODRIGUEZ ALFARO
La respuesta en frecuencia de sistemas lineales es una popular herramienta utilizada en el análisis y diseño de sistemas de control automático. La forma común de obtener la respuesta en frecuencia es a partir de la representación entrada-salida (función de transferencia) de un sistema. En este trabajo se presenta una manera novedosa para obtener la respuesta en frecuencia partiendo de la representación en el espacio de estados. El resultado es obtenido mediante la caracterización de la señal de entrada (función senoidal) mediante un sistema externo adicional, así como la evaluación del estado estacionario. La determinación de la fase y magnitud se obtiene de la solución a una ecuación de Sylvester reiteradamente para diferentes valores de la frecuencia en un intervalo específico junto con algunas manipulaciones algebraicas y uso de identidades trigonométricas. El procedimiento es mostrado mediante ejemplos y comparado con las maneras clásicas de obtener la respuesta en frecuencia.