JUN KAWAI

Prof. Dr. JUN KAWAI

orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2016 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
JKJUN KAWAI
JUN KAWAI
HOHirokuni Oda
Hirokuni Oda
JFJunichi Fujihira
Junichi Fujihira
MMMasakazu Miyamoto
Masakazu Miyamoto
IMIsoji Miyagi
Isoji Miyagi
MSMasahiko Sato
Masahiko Sato
We have developed a high-spatial-resolution superconducting quantum interference device (SQUID) microscope for magnetic field imaging of rock samples at room temperature, using a hollow-structured cryostat. A directly coupled low-temperature SQUID with a 200 μm × 200 μm pickup loop, which is mounted on a sapphire conical rod, is separated from room temperature by a thin sapphire window. Precise and repeatable adjustment of the vacuum gap between the SQUID and the sapphire window is performed by rotating a micrometer spindle connected to the sapphire rod through the hollow portion of the cryostat. A spacing of 230 μm between the SQUID and a sample has been achieved. We demonstrated the imaging of the magnetic field on a zircon containing magnetic grains.

6 December 2007 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
YAYoshiaki Adachi
Yoshiaki Adachi
JKJUN KAWAI
JUN KAWAI
GUGen Uehara
Gen Uehara
MMMasakazu Miyamoto
Masakazu Miyamoto
STShoji Tomizawa
Shoji Tomizawa
SKShigenori Kawabata
Shigenori Kawabata
A 75-ch SQUID biomagnetometer system for the measurement of the cervical spinal cord evoked magnetic field (SCEF) was developed for the purpose of the noninvasive functional diagnosis of the spinal cord. The sensor array has 25 SQUID vector sensors arranged along the cylindrical surface to fit to the shape of the subject's neck. The magnetic fields, not only in the direction radial to the subject's body surface but also in the tangential direction, are observed in the area of 80 mm times 90 mm at one time. The dewar has a unique shape with a cylindrical main body and a protrusion from its side surface. The sensor array is installed in the protruded part. This design is optimized to detect magnetic signals at the back of the neck of the subject sitting in a reclining position. We applied the developed SQUID system to the cervical SCEF measurement of normal subjects who were given electric pulse stimulation to their median nerves at the wrists. The evoked magnetic signals were successfully detected at the cervixes of all subjects. A characteristic pattern of transition of the SCEF distribution was observed as a reproducible result and the signal components propagating along the spinal cord were found in the time varying SCEF distribution. We expect that the investigation of the propagating signal components would help to establish a noninvasive functional diagnosis of the spinal cord.

12 July 2017 in Journal of Geophysical Research: Space Physics
Verified
Journal Article
Open access
PDF file
MNM. Nosé
M. Nosé
MUM. Uyeshima
M. Uyeshima
JKJUN KAWAI
JUN KAWAI
HHH. Hase
H. Hase
The ionospheric Alfvén resonator (IAR) is found in a dynamic power spectrum of the geomagnetic field variations as spectral resonance structures in the frequency range of 0.1–10 Hz. To date, observations of IAR at low latitude have only been made by a few studies employing a single ground observatory and are not sufficient enough to reveal its general characteristics. We analyze data measured with an induction magnetometer installed at Muroto, Japan (24.40° geomagnetic latitude) for the period from 28 December 2013 to 13 August 2016. A statistical analysis reveals that the occurrence probability of the low‐latitude IAR is (1) dominant during nighttime with a gradual increase from dusk to midnight and a broad maximum at 00–05 LT followed by a sudden decrease at dawn, (2) slightly higher during May through September, and (3) independent of the Kp index for Kp ≤ 5. We also find that (4) the frequency separation between the harmonics (Δf) of the low‐latitude IAR is 0.1–0.5 Hz with a peak at 0.2–0.275 Hz. These observational results are compared with the model calculation results along with previous studies about possible energy sources. It is found that the global thunderstorm activity is a likely source for IAR at Muroto; that is, it produces electromagnetic disturbances that are converted into the Alfvén waves and that are then trapped in the ionospheric cavity bounded by the conductive E layer and a steep gradient of Alfvén velocity above the F2 layer to form the resonant Alfvén waves.

27 June 2017 in Superconductor Science and Technology
Verified
Journal Article
Closed access
PDF file
JKJUN KAWAI
JUN KAWAI
MMM Miyamoto
M Miyamoto
MKM Kawabata
M Kawabata
MNM Nosé
M Nosé
YHY Haruta
Y Haruta
GUG Uehara
G Uehara
We characterized a low temperature superconducting quantum interference device (SQUID) magnetometer system developed for high-sensitivity geomagnetic field measurement, and demonstrated the detection of weak geomagnetic signals. The SQUID magnetometer system is comprised of three-axis SQUID magnetometers housed in a glass fiber reinforced plastic cryostat, readout electronics with flux locked loop (FLL), a 24-bit data logger with a global positioning system and batteries. The system noise was approximately 0.2 pT √Hz − 1/2 in the 1–50 Hz frequency range. This performance was determined by including the thermal noise and the shielding effect of the copper shield, which covered the SQUID magnetometers to eliminate high-frequency interference. The temperature drift of the system was ∼0.8 pT °C − 1 in an FLL operation. The system operated for a month using 33 l liquid helium. Using this system, we performed the measurements of geomagnetic field in the open-air, far away from the city. The system could detect weak geomagnetic signals such as the Schumann resonance with sixth harmonics, and the ionospheric Alfvén resonance appearing at night, for the north–south and east–west components of the geomagnetic field. We confirm that the system was capable of high-sensitivity measurement of the weak geomagnetic activities.

3 June 2017 in Geophysical Research Letters
Verified
Journal Article
Open access
PDF file
ANA. Noguchi
A. Noguchi
HOHirokuni Oda
Hirokuni Oda
YYY. Yamamoto
Y. Yamamoto
AUA. Usui
A. Usui
MSM. Sato
M. Sato
JKJUN KAWAI
JUN KAWAI
Ferromanganese crusts record long‐term deep‐sea environmental changes. Thus, providing their reliable high‐resolution age models is important. We applied a magnetostratigraphic technique to estimate the growth rate of a ferromanganese crust using scanning SQUID (superconducting quantum interference device) microscope (SSM). SSM is designed to map the magnetic field across thin sections with submillimeter resolution. The crust sample was taken from the Takuyo‐Daigo Seamount, northwestern Pacific, and recorded a limited supply of dust and sediment from continents. After drift correction and removal of spike noises, the magnetic field values were stacked within the areas of high signal‐to‐noise ratios. By correlating the obtained profiles with a standard geomagnetic polarity timescale, we obtained an average growth rate of 3.37 ± 0.06 mm/Ma, which is consistent with that obtained by 10Be/9Be geochronology (2.93 ± 0.15 mm/Ma). S ratio mapping shows low values after ~3 Ma, associated with voids between columnar structures.

1 January 2010 in MATERIALS TRANSACTIONS
Verified
Journal Article
Open access
KYKoretaka Yuge
Koretaka Yuge
Takayuki IchikawaTakayuki Ichikawa
Takayuki Ichikawa
JKJUN KAWAI
JUN KAWAI
Energetic stability and electronic structures of Pt atoms in Pt-Rh nanoparticle is investigated by first-principles calculation. Pt atom energetically prefer surface sites (vertex, edge, and (100)) rather than subsurface and core site, which is attributed to lower Pt surface energy compared with Rh. Vertex of nanoparticle is the most favorable site for Pt atom, which has lowest coordination numbers. Band center of d-state electronic contribution for Pt atom measured from the Fermi energy exhibit negative dependence with respect to Pt coordination number. This can be attributed to positive dependence of second-order moment of density of states for the Pt d-band on the coordination number. Pt segregation to the surface is expected due mainly to contribution from Pt on-site segregation energy compared with weak ordering tendency of Pt-Rh unlike-atom pairs. [doi:10.2320/matertrans.M2009295