Yoshiaki Adachi

Yoshiaki Adachi

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2019 in IEEE Transactions on Magnetics
Verified
Journal Article
Open access
YAYoshiaki Adachi
Yoshiaki Adachi
ODOyama Daisuke
Oyama Daisuke
YTYasushi Terazono
Yasushi Terazono
THTatsuya Hayashi
Tatsuya Hayashi
TSTomohiko Shibuya
Tomohiko Shibuya
SKShigenori Kawabata
Shigenori Kawabata
Biomagnetic field measurement is a promising tool for the investigation of electrical activities in a living body. Room temperature (RT) magnetic sensors with an improved resolution such as magnetoresistance (MR) devices have been recently employed for the detection of weak magnetic fields, which were earlier detected solely using superconducting interference device magnetic sensors. The position, orientation, and sensitivity of each magnetic sensor in a sensor array must be precisely determined for accurate magnetic source analysis. We proposed a calibration method using an array of multiple coils, which is applicable to an RT magnetic sensor array. To demonstrate the validity of the proposed calibration method, we applied it to an MR device-based magnetocardiography (MCG) system equipped with an L-shaped planar sensor array, which was newly developed for the simultaneous observation of both anterior and lateral sides of the body. The deviation of the sensor parameters from the designed values was estimated via calibration. The result of the marker coil localization test indicated that the calibration considerably improved the accuracy of the magnetic source analysis. Finally, we demonstrated a preliminary MCG measurement using the calibrated magnetic sensor array.

3 May 2017 in Superconductor Science and Technology
Verified
Journal Article
Closed access
PDF file
YAYoshiaki Adachi
Yoshiaki Adachi
JKJun Kawai
Jun Kawai
YHYasuhiro Haruta
Yasuhiro Haruta
MMMasakazu Miyamoto
Masakazu Miyamoto
SKShigenori Kawabata
Shigenori Kawabata
GUGen Uehara
Gen Uehara
In this study, a new superconducting quantum interference device (SQUID) biomagnetic measurement system known as magnetospinogram (MSG) is developed. The MSG system is used for observation of a weak magnetic field distribution induced by the neural activity of the spinal cord over the body surface. The current source reconstruction for the observed magnetic field distribution provides noninvasive functional imaging of the spinal cord, which enables medical personnel to diagnose spinal cord diseases more accurately. The MSG system is equipped with a uniquely shaped cryostat and a sensor array of vector-type SQUID gradiometers that are designed to detect the magnetic field from deep sources across a narrow observation area over the body surface of supine subjects. The latest prototype of the MSG system is already applied in clinical studies to develop a diagnosis protocol for spinal cord diseases. Advancements in hardware and software for MSG signal processing and cryogenic components aid in effectively suppressing external magnetic field noise and reducing the cost of liquid helium that act as barriers with respect to the introduction of the MSG system to hospitals. The application of the MSG system is extended to various biomagnetic applications in addition to spinal cord functional imaging given the advantages of the MSG system for investigating deep sources. The study also includes a report on the recent advancements of the SQUID MSG system including its peripheral technologies and wide-spread applications.

6 December 2007 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
YAYoshiaki Adachi
Yoshiaki Adachi
JKJUN KAWAI
JUN KAWAI
GUGen Uehara
Gen Uehara
MMMasakazu Miyamoto
Masakazu Miyamoto
STShoji Tomizawa
Shoji Tomizawa
SKShigenori Kawabata
Shigenori Kawabata
A 75-ch SQUID biomagnetometer system for the measurement of the cervical spinal cord evoked magnetic field (SCEF) was developed for the purpose of the noninvasive functional diagnosis of the spinal cord. The sensor array has 25 SQUID vector sensors arranged along the cylindrical surface to fit to the shape of the subject's neck. The magnetic fields, not only in the direction radial to the subject's body surface but also in the tangential direction, are observed in the area of 80 mm times 90 mm at one time. The dewar has a unique shape with a cylindrical main body and a protrusion from its side surface. The sensor array is installed in the protruded part. This design is optimized to detect magnetic signals at the back of the neck of the subject sitting in a reclining position. We applied the developed SQUID system to the cervical SCEF measurement of normal subjects who were given electric pulse stimulation to their median nerves at the wrists. The evoked magnetic signals were successfully detected at the cervixes of all subjects. A characteristic pattern of transition of the SCEF distribution was observed as a reproducible result and the signal components propagating along the spinal cord were found in the time varying SCEF distribution. We expect that the investigation of the propagating signal components would help to establish a noninvasive functional diagnosis of the spinal cord.

1 April 2020 in Clinical Neurophysiology
Verified
Journal Article
Open access
TSToru Sasaki
Toru Sasaki
SKShigenori Kawabata
Shigenori Kawabata
YHYuko Hoshino
Yuko Hoshino
KSKensuke Sekihara
Kensuke Sekihara
YAYoshiaki Adachi
Yoshiaki Adachi
AOAtsushi Okawa
Atsushi Okawa
To establish a noninvasive method to measure the neuromagnetic fields of the median nerve at the carpal tunnel after electrical digital nerve stimulation and evaluate peripheral nerve function. Using a vector-type biomagnetometer system with a superconducting quantum interference device, neuromagnetic fields at the carpal tunnel were recorded after electrical stimulation of the index or middle digital nerve in five healthy volunteers. A novel technique for removing stimulus-induced artifacts was applied, and current distributions were calculated using a spatial filter algorithm and superimposed on X-ray. A neuromagnetic field propagating from the palm to the carpal tunnel was observed in all participants. Current distributions estimated from the magnetic fields had five components: leading and trailing components parallel to the conduction pathway, outward current preceding the leading component, inward currents between the leading and trailing components, and outward current following the trailing component. The conduction velocity and peak latency of the inward current agreed well with those of sensory nerve action potentials. Removing stimulus-induced artifacts enabled magnetoneurography to noninvasively visualize with high spatial resolution the electrophysiological neural activity from the palm to the carpal tunnel. This is the first report of using magnetoneurography to visualize electrophysiological nerve activity at the palm and carpal tunnel.

21 November 2016 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
YAYoshiaki Adachi
Yoshiaki Adachi
SKShigenori Kawabata
Shigenori Kawabata
JFJun-Ichi Fujihira
Jun-Ichi Fujihira
GUGen Uehara
Gen Uehara
We developed a magnetospinogram (MSG) system equipped with a closed-cycle helium recondensing unit. The MSG system detects weak magnetic fields evoked by neural activity of spinal cords using superconducting quantum interference devices (SQUIDs) and provides functional images effective for the diagnosis of spinal cord diseases. Thus far, the cost of liquid helium (LHe) required to maintain the superconductivity of the SQUID magnetometers has prevented the MSG from being used widely. Here, we combine an LHe recycling system using a pulse tube cryocooler and a low-loss transfer tube for transporting LHe to the system. This allows the superconducting state of SQUIDs to be maintained for half a year without refilling the LHe. The frequency band of noise from the recondensing system was different from that of the MSG signals. Therefore, the MSG signals were obtained at a sufficient signal-to-noise ratio even when the recondensing system, which is located just beside the magnetically shielded room, was in operation. In this paper, the details of the developed MSG system and the results from preliminary measurements using the system are reported.

1 January 2022 in Clinical Neurophysiology
Verified
Journal Article
Open access
JHJun Hashimoto
Jun Hashimoto
SKShigenori Kawabata
Shigenori Kawabata
TSToru Sasaki
Toru Sasaki
YHYuko Hoshino
Yuko Hoshino
KSKensuke Sekihara
Kensuke Sekihara
AOAtsushi Okawa
Atsushi Okawa
Noninvasive and detailed visualization of electrophysiological activity in the thoracic spinal cord through magnetoneurography. In five healthy volunteers, magnetic fields around current flowing in the thoracic spinal cord after alternating unilateral and synchronized bilateral sciatic nerve stimulation were measured using a magnetoneurograph system with superconductive quantum interference device biomagnetometers. The current distribution was obtained from the magnetic data by spatial filtering and visualized by superimposing it on the X-ray image. Conduction velocity was calculated using the peak latency of the current waveforms. A sufficiently high magnetic signal intensity and signal-to-noise ratio were obtained in all participants after synchronized bilateral sciatic nerve stimulation. Leading and trailing components along the spinal canal and inward components flowing into the depolarization site ascended to the upper thoracic spine. Conduction velocity of the inward current in the whole thoracic spine was 42.4 m/s. Visualization of electrophysiological activity in the thoracic spinal cord was achieved through magnetoneurography and a new method for synchronized bilateral sciatic nerve stimulation. Magnetoneurography is expected to be a useful modality in functional assessment of thoracic myelopathy. This is the first report to use magnetoneurography to noninvasively visualize electrophysiological activity in the thoracic spinal cord in detail.