Jozef Selin

Dr. Jozef Selin

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2026 in Water
Verified
Journal Article
Open access
PDF file
SASetah Naser Alowfi
Setah Naser Alowfi
Islam M. HamdiIslam M. Hamdi
Islam M. Hamdi
JSJozef Selin
Jozef Selin
AAAmnah Aldohan
Amnah Aldohan
Martina ZelenakovaMartina Zelenakova
Martina Zelenakova
Youssef M. YoussefYoussef M. Youssef
Youssef M. Youssef
Lake Nasser represents Egypt’s principal strategic freshwater reservoir; however, its long-term phytoplankton dynamics at the basin scale remain insufficiently characterized. This study presents a detailed spatiotemporal investigation of chlorophyll-a (Chl-a) variability across the reservoir during the 2002–2020 period using exclusively MODIS-Aqua Level-3 satellite observations. As no concurrent in situ measurements were available for validation, the reported values are treated as satellite-derived Chl-a estimates rather than direct observations of phytoplankton biomass. A non-parametric statistical approach, incorporating the Mann–Kendall test, Theil–Sen slope estimator, coefficient of variation (CV), and relative anomaly analysis, was used to characterize pixel-level climatology and temporal trends. The findings demonstrate that the reservoir exhibits pronounced spatial heterogeneity and a well-defined bimodal seasonal pattern associated with the annual Blue Nile flood pulse during August–October and winter convective mixing processes between November and February. Although annual-scale analysis did not indicate a statistically significant monotonic trend, seasonal investigations revealed strongly contrasting temporal responses throughout the year. At the pixel level, significant increases dominated ten of the twelve calendar months, from September through June, with median slopes among significant pixels of +0.36 to +1.47 mg m−3 yr−1. July and August reversed this pattern, combining significant declines along the northern and central main channel with the steepest increases in the record at the extreme southern inflow. The directional contrast was unaffected by control of the false discovery rate within each calendar month (q = 0.05), which retained 66% of the significant pixels. Summer conditions were additionally marked by substantial temporal variability (CV > 60%) and pronounced positive anomalies, reaching +274.51% during August. Notably, these anomalies were spatially concentrated within the central and southern sectors of the reservoir, rather than within the conventionally productive northern region. This spatial redistribution, together with the broad enrichment tendency indicated by the pixel-level trends, points to an intensification of the summer maximum within the southern inflow zone and to a possible emergence of localized eutrophication risk, a hypothesis that requires confirmation through concurrent nutrient, transparency, and dissolved-oxygen observations. Overall, the study provides valuable geospatial insights for the environmental management of Lake Nasser, emphasizing the importance of implementing targeted early-warning systems for harmful algal bloom monitoring. The results also demonstrate the critical role of satellite-based Earth observation technologies in supporting adaptive water resource management under evolving climatic and hydrological conditions.

24 March 2026 in Buildings
Verified
Journal Article
Open access
PDF file
AEAhmed S. Eisa
Ahmed S. Eisa
AAAhmad Abdallah Attia
Ahmad Abdallah Attia
JSJozef Selin
Jozef Selin
PPPavol Purcz
Pavol Purcz
The integration of real-time monitoring capabilities into concrete materials offers significant potential for improving the safety and durability of building infrastructure. This study investigates the real-time electromechanical behavior of steel fiber-reinforced self-sensing concrete under compressive and splitting tensile loading. Eighteen cubes (150 × 150 × 150 mm) and eighteen cylinders (150 × 300 mm) containing 0.5%, 1.5%, and 3% steel fiber volume fractions were tested. Electrical resistance was continuously recorded at one-second intervals using an Arduino–ESP32-based system, enabling in situ tracking of damage evolution. The conductive steel fiber network functioned as an intrinsic sensing phase, where load-induced microstructural changes altered electrical pathways. Resistance variations consistently preceded visible cracking, with pronounced nonlinear increases observed at 65–80% of peak load, indicating micro-crack initiation. Distinct electromechanical stages were identified, including elastic stability, compaction-induced resistance reduction near yield, and rapid resistance growth during crack propagation. Higher fiber contents improved both mechanical performance and sensing sensitivity through enhanced crack-bridging and conductive network stability. Although curing age influenced baseline resistance, reliable real-time damage detection was achieved across all specimens. The findings demonstrate the feasibility of steel fiber-reinforced concrete as a cost-effective, distributed monitoring material for early damage detection in building structures.

27 August 2026 in Water
Verified
Journal Article
Open access
PDF file
MSMarwa F. Shaheen
Marwa F. Shaheen
SASamy Abdel-Fattah
Samy Abdel-Fattah
Martina ZelenakovaMartina Zelenakova
Martina Zelenakova
JSJozef Selin
Jozef Selin
Mohamed Galal ElbagouryMohamed Galal Elbagoury
Mohamed Galal Elbagoury
Piano key weirs (PKWs) increase the effective crest length and provide high discharge capacity within limited spillway widths; however, their hydraulic efficiency depends on key geometry. Addressing the limited understanding of key-curvature effects, this study systematically investigates the influence of inlet- and outlet-key curvature on the discharge coefficient (Cd) and crest-wise discharge distribution of type-A PKWs. Nine configurations are examined experimentally in a flume at the Hydraulics Research Institute, Egypt. These include a reference model with linear inlet and outlet keys and modified geometries incorporating C- and S-shaped keys in both normal and inverted forms. Experiments are conducted under free-flow conditions for total-head ratios HT/P up to 0.23, where HT is the total upstream head above the crest and P is the PKW height. A three-dimensional numerical model using FLOW-3D HYDRO is validated against these experimental data and subsequently extended to HT/P ≈ 0.50–0.60. All reported results and conclusions are based on the numerical simulations over the full investigated range. Results show that Cd increases to a peak near HT/P ≈ 0.08 and then decreases gradually for all configurations. Both inlet- and outlet-key curvature influence hydraulic performance by modifying flow guidance and redistribution along the crest. However, only the inverted C-shaped inlet configuration (M2) improves efficiency, increasing Cd by about 5.46% on average over the investigated head range and enhancing the total discharge by approximately 4.36% at HT/P ≈ 0.12 relative to the reference case. Discharge-distribution analysis indicates that this improvement results from inlet feeding and efficient flow conveyance along the sidewall crest. A predictive relation is developed for the optimal configuration to support hydraulic design.

27 July 2026 in Buildings
Verified
Journal Article
Open access
PDF file
AGAmr Ghoneim
Amr Ghoneim
LALouay A. Aboul-Nour
Louay A. Aboul-Nour
Erika DolníkováErika Dolníková
Erika Dolníková
JSJozef Selin
Jozef Selin
Dušan KatunskýDušan Katunský
Dušan Katunský
Mohamed Hamdy El-FekyMohamed Hamdy El-Feky
Mohamed Hamdy El-Feky
Expanded Polystyrene (EPS) offers a viable pathway for balancing the fresh and hardened properties of infrastructure with environmental sustainability. This study evaluated six concrete mixes with varying EPS Styrofoam aggregate ratios and three water-to-binder (w/b) ratios, all of which incorporated silica fume and a superplasticizer. Eight machine learning (ML) algorithms (SVMs, GPR, ANNs, etc.) and a deep-learning LSTM model were utilized to preliminarily predict trends in EPS concrete properties. The experimental results indicated that the fine aggregate replacement outperformed the coarse aggregate replacement, retaining approximately 76% of the density of the control mixture, along with other property reductions. The fine aggregate replacement resulted in a compressive strength reduction of up to 46.4%, with losses in tensile strength of 20.9% and an improvement in workability of 3.4%. Finally, various Artificial intelligence (AI) models identified trends in the predictions of EPS properties based on the mixing ratio within a limited experimental dataset. In addition, explainable AI with SHAP analysis, quantifying feature contributions, ensured that the coarse aggregate replacement exerted a more significant negative impact on the mechanical properties and density than the fine aggregate replacement. Although these mixtures offer significant weight reduction, their use in structural applications requires further verification, as the reduction of nearly half of the compressive strength is significant. These findings provide strategies and a framework to facilitate the precise practical application of EPS concrete in nonstructural or lightly loaded applications.

4 June 2026 in Results in Engineering
Verified
Journal Article
Open access
Tarek Nageeb SalemTarek Nageeb Salem
Tarek Nageeb Salem
HEHussein M. El-Demerdash
Hussein M. El-Demerdash
NENadia M. El-Khawas
Nadia M. El-Khawas
JSJozef Selin
Jozef Selin
Dušan KatunskýDušan Katunský
Dušan Katunský

22 October 2026 in Water
Verified
Journal Article
Open access
PDF file
Mohamed Galal ElbagouryMohamed Galal Elbagoury
Mohamed Galal Elbagoury
SASamy Abdel-Fattah
Samy Abdel-Fattah
Martina ZelenakovaMartina Zelenakova
Martina Zelenakova
JSJozef Selin
Jozef Selin
MSMarwa F. Shaheen
Marwa F. Shaheen
Piano key weirs (PKWs) provide high discharge efficiency within a limited footprint, but the influence of inlet- and outlet-key shapes on their energy dissipation has received limited attention. This study investigates the effects of curved inlet- and outlet-key geometries on PKW energy dissipation using 102 free-flow experimental runs. Nine configurations are tested: a linear reference (M1) and C-shaped, inverted C-shaped, S-shaped, and inverted S-shaped modifications applied separately to the inlet and outlet keys. A FLOW-3D HYDRO model is validated against the measurements, reproducing the total head with R2 = 0.997 and RMSE = 0.0013 m and the relative energy loss within ±15% (MAPE = 6.70%), and is then used to evaluate a combined configuration (M10) with C-shaped inlet and outlet keys. Experimental results show that the relative energy loss decreases with increasing total head ratio, from approximately 71–74% at low heads to 46–52% at higher heads. At HT/P = 0.18, the C-shaped inlet (M4) and outlet (M5) increase the relative energy loss by 12.80% and 8.27%, respectively, relative to M1. Compared with the numerically simulated M1, M10 is predicted to increase the relative energy loss by 5.86%, 9.64%, and 14.61% at HT/P = 0.08, 0.12, and 0.18, respectively. A logarithmic relationship fitted to 11 numerical runs is provided for estimating the relative energy loss of M10 within HT/P = 0.075–0.266. The results show that PKW energy dissipation depends strongly on curvature shape, orientation, and key location.