The objective of this study is to improve the exit flow uniformity of a gas torch with multiple exit holes for effective heating of a steel plate. The torch was simulated, and combustion experiments were performed for validation. Based on a basic model, three different revised models were designed and analyzed with the software ANSYS FLUENT 18.2. The flow uniformity (γ) of the velocity distribution at the multiple exit holes was investigated with the pressure drop ranging from 100 to 500 Pa. The basic model had flow uniformity ranging from 0.849 to 0.852, but the three new models had γ1 = 0.901–0.912, γ2 = 0.902–0.911, and γ3 = 0.901–0.914, respectively. The maximum percentage difference of the flow uniformity index between the three new models and the basic model was 7.3%. The basic model with nonuniform flow distribution made a temperature difference of the back side of the steel plate from the center to the edge of around 229 °C, while the modified model with uniform flow distribution had a smaller temperature difference of 90 °C. The simulation results showed good agreement with our experimental results for both the basic model and the modified model. The modified gas torch made a wider and more uniform temperature distribution on a preheated steel plate than the basic one. The results revealed that a trade-off between cost and flow uniformity, as well as the new gas torch, could be applied to a steel-plate preheating process before welding.
The temperature distribution on a steel plate during a preheating process was compared using gas torch models with and without guide vanes. Numerical simulations were done using ANSYS FLUENT software, and experiments were done using thermal images obtained by a TVS-200EX infrared thermal camera. Liquefied petroleum gas (LPG) was used as fuel for the gas torch in the simulation and experiment. The temperature distribution on the steel plate and the flame region were first compared. The temperature increase caused by the flame concentration with the guide vanes was 65 °C. The transient and steady-state temperature distribution on the back side of the steel plate were then examined. The results showed good agreement between the simulation and experimental results. At steady state, the back-side temperature deviation of the steel plate between the numerical simulation and experimental results was approximately 4.9%. The effects of the equivalence ratio (Φ), Reynolds number (Re), and the downstream distance ratio of the combustion gas from the torch outlet to the steel plate (H/d) on the temperature distribution were also investigated. The highest temperature distribution was found in stoichiometric combustion. The temperature of the plate increased as the Reynolds number increased from 2368 to 4876 but decreased as the distance ratio (H/d) increased from 25 to 75. The guide vane angles at the gas torch outlet were from 30 to 60 degrees, and the angle of 40 degrees resulted in the highest temperature of the steel plate.
8 December 2021 in Journal of Mechanical Science and Technology
태양열 가열을 도입한 해양온도차발전용 열교환기(증발기와 응축기)설계 최적화가 수행되었다. 출력은 100kW이고 작동유체는 R134a이며 고성능 상용튜브를 사용하였다. 열전달면적과 압력강하는 관수의 증가와 관통로수의 감소에 따라 서로 상반되는 경향이 존재하므로 이를 해결하기 위하여, 설비투자비에 관련되는 열전달면적과 압력강하에 관련되는 운전비용 최소화를 고려한 두 목적함수를 갖는 유전자 알고리즘(GA)을 이용하여 다목적설계최적화를 수행하였다. 설계최적화 결과, 구현 가능한 최적의 열전달면적 및 압력강하의 조합들이 적정한 관수 및 관통로 수에 대하여 존재하였다. 도출된 증발기와 응축기의 Pareto 선들은 설계자들에게 재정적인 면을 고려하여 선택할 수 있도록 넓은 범위의 최적해를 제공하였다. 또한, 총열전달면적 중 응축기의 열전달면적이 증발기 쪽보다 크게 나타났다.
31 October 2019 in Transactions of the Korean Society of Mechanical Engineers - B
본 연구의 목적은 소둔로의 입구 구조를 변경하여 내부에 배열된 강관 군 사이의 온도차를 최소화 하는 것이다. 기본 및 수정된 소둔로 내부의 유동장 및 강관의 온도 분포를 ANSYS FLUENT 18.2 소프트웨어를 사용하여 조사하였다. 3개의 수정된 입구 모델은, 스월 유동을 생성하기 위해 엘보우 입구를 채택하고, 하향 제트유동 생성 후 상향 부력 흐름이 발생되도록 엘보우의 수평방향에 대한 하향 제트각은 0도에서 45도 범위에서 설계되었다. 기본 모델에 대한 강관 군의 온도 차는 37℃이었다. 반면, 하향 제트각 0도, 30도 및 45도 엘보우들을 사용한 강관 군의 온도 차는 각각 10℃, 8℃ 및 15℃이었다. 하향 제트각 30도 부근의 엘보우는 강관 군 사이의 온도 차를 줄이기 위해 본 연구 범위 내에서 최적화된 각도이었다. 본 연구로부터, 소둔로에서 강관 군 간의 온도 차의 최소화는, 적정각의 하향 분사 엘보우 입구를 사용한 입구형상을 통해서도 달성될 수 있음을 알 수 있었다.
1 October 2018 in Transactions of the Korean Society of Mechanical Engineers - B
The hot mixing chamber (HMC) is a device that mixes streams of fluid to obtain gas with a pertinent operational temperature in the final outlet section that can meet the industry requirements. In this numerical simulation study, the flow and temperature characteristics in the hot mixing chamber in different cold air inlets conditions were obtained using the software FLUENT. The number of cold air inlets was 2, 3 and 4. For the two cold air inlets, there were four models with various inlet angles of 90 degrees, 120 degrees, 150 degrees and 180 degrees. Therefore, a total of six models including 3 air inlets angle of 120 degrees and 4 air inlets angle of 90 degrees, were simulated in this study. The simulation results showed the model with 3 cold air inlets had the best performance for the highest temperature uniformity at the HMC outlet and the lowest wall temperature over the surface of the HMC.