Jose Vicente Lidon-Roger

Mr. Jose Vicente Lidon-Roger

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2018 in Sensors
Verified
Journal Article
Open access
PDF file
JLJose Vicente Lidon-Roger
Jose Vicente Lidon-Roger
GPGema Prats-Boluda
Gema Prats-Boluda
YYYiyao Ye-Lin
Yiyao Ye-Lin
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
Eduardo Garcia-BreijoEduardo Garcia-Breijo
Eduardo Garcia-Breijo
Among many of the electrode designs used in electrocardiography (ECG), concentric ring electrodes (CREs) are one of the most promising due to their enhanced spatial resolution. Their development has undergone a great push due to their use in recent years; however, they are not yet widely used in clinical practice. CRE implementation in textiles will lead to a low cost, flexible, comfortable, and robust electrode capable of detecting high spatial resolution ECG signals. A textile CRE set has been designed and developed using screen-printing technology. This is a mature technology in the textile industry and, therefore, does not require heavy investments. Inks employed as conductive elements have been silver and a conducting polymer (poly (3,4-ethylenedioxythiophene) polystyrene sulfonate; PEDOT:PSS). Conducting polymers have biocompatibility advantages, they can be used with flexible substrates, and they are available for several printing technologies. CREs implemented with both inks have been compared by analyzing their electric features and their performance in detecting ECG signals. The results reveal that silver CREs present a higher average thickness and slightly lower skin-electrode impedance than PEDOT:PSS CREs. As for ECG recordings with subjects at rest, both CREs allowed the uptake of bipolar concentric ECG signals (BC-ECG) with signal-to-noise ratios similar to that of conventional ECG recordings. Regarding the saturation and alterations of ECGs captured with textile CREs caused by intentional subject movements, silver CREs presented a more stable response (fewer saturations and alterations) than those of PEDOT:PSS. Moreover, BC-ECG signals provided higher spatial resolution compared to conventional ECG. This improved spatial resolution was manifested in the identification of P1 and P2 waves of atrial activity in most of the BC-ECG signals. It can be concluded that textile silver CREs are more suitable than those of PEDOT:PSS for obtaining BC-ECG records. These developed textile electrodes bring the use of CREs closer to the clinical environment.

1 June 2017 in Organic Electronics
Verified
Journal Article
Open access
LCLaura Contat-Rodrigo
Laura Contat-Rodrigo
CFClara Pérez Fuster
Clara Pérez Fuster
JLJose Vicente Lidon-Roger
Jose Vicente Lidon-Roger
ABAnnalisa Bonfiglio
Annalisa Bonfiglio
EGEduardo García-Breijo
Eduardo García-Breijo

20 December 2017 in Materials
Verified
Journal Article
Open access
PDF file
JFJosue Ferri
Josue Ferri
JLJose Vicente Lidon-Roger
Jose Vicente Lidon-Roger
JMJorge Moreno
Jorge Moreno
GMGabriel Martinez
Gabriel Martinez
Eduardo Garcia-BreijoEduardo Garcia-Breijo
Eduardo Garcia-Breijo
Among many of the designs used in the detection of 2D gestures for portable technology, the touchpad is one of the most complex and with more functions to implement. Its development has undergone a great push due to its use in displays, but it is not widely used with other technologies. Its application on textiles could allow a wide range of applications in the field of medicine, sports, etc. Obtaining a flexible, robust touchpad with good response and low cost is one of the objectives of this work. A textile touchpad based on a diamond pattern design using screen printing technology has been developed. This technology is widely used in the textile industry and therefore does not require heavy investments. The developed prototypes were analyzed using a particular controller for projected capacitive technologies (pro-cap), which is the most used in gesture detection. Two different designs were used to obtain the best configuration, obtaining a good result in both cases.

28 September 2016 in Sensors
Verified
Journal Article
Open access
PDF file
LRLaura Contat Rodrigo
Laura Contat Rodrigo
CFClara Pérez Fuster
Clara Pérez Fuster
JLJose Vicente Lidon-Roger
Jose Vicente Lidon-Roger
ABAnnalisa Bonfiglio
Annalisa Bonfiglio
Eduardo Garcia-BreijoEduardo Garcia-Breijo
Eduardo Garcia-Breijo
A novel screen-printing fabrication method was used to prepare organic electrochemical transistors (OECTs) based on poly(3,4-ethylenedioxythiophene) doped with polysterene sulfonate (PEDOT:PSS). Initially, three types of these screen-printed OECTs with a different channel and gate areas ratio were compared in terms of output characteristics, transfer characteristics, and current modulation in a phosphate buffered saline (PBS) solution. Results confirm that transistors with a gate electrode larger than the channel exhibit higher modulation. OECTs with this geometry were therefore chosen to investigate their ion-sensitive properties in aqueous solutions of cations of different sizes (sodium and rhodamine B). The effect of the gate electrode was additionally studied by comparing these all-PEDOT:PSS transistors with OECTs with the same geometry but with a non-polarizable metal gate (Ag). The operation of the all-PEDOT:PSS OECTs yields a response that is not dependent on a Na+ or rhodamine concentration. The weak modulation of these transistors can be explained assuming that PEDOT:PSS behaves like a supercapacitor. In contrast, the operation of Ag-Gate OECTs yields a response that is dependent on ion concentration due to the redox reaction taking place at the gate electrode with Cl− counter-ions. This indicates that, for cation detection, the response is maximized in OECTs with non-polarizable gate electrodes.

5 May 2015 in Microelectronics International
Verified
Journal Article
Closed access
EGEduardo Garcia-Breijo
Eduardo Garcia-Breijo
GPGema Prats-Boluda
Gema Prats-Boluda
JLJose Vicente Lidon-Roger
Jose Vicente Lidon-Roger
YYYiyao Ye-Lin
Yiyao Ye-Lin
Javier Garcia-CasadoJavier Garcia-Casado
Javier Garcia-Casado
Purpose: – This paper aims to present a comparison between three types of manufacturing techniques, namely, screen-printed, inkjet and gravure, using different types of inks, for the implementation of concentric ring electrodes which permit estimation of Laplacian potential on the body surface. Design/methodology/approach: – Flexible concentric ring electrodes not only present lower skin–electrode contact impedance and lower baseline wander than rigid electrodes but are also less sensitive to interference and motion artefacts. The above three techniques allow printing of conductive inks on flexible substrates, and with this work, the authors aim to study which is the best technique and ink to obtain the best electrode response. Findings: – From the results obtained regarding ink thickness, resistivity, electrode resistance and other performance parameters derived from electrocardiographic signal recording tests, it can be said that concentric electrodes using the screen-printing and inkjet techniques are suitable for non-invasive bioelectric signal acquisition. Originality/value: – The development of new types of inks and substrates for the electronics industry and the adaptation of new manufacturing techniques allow for an improvement in the development of electrodes and sensors.

22 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JFJosue Ferri
Josue Ferri
RLRaul Llinares
Raul Llinares
GMGabriel Martinez
Gabriel Martinez
JLJose Vicente Lidon-Roger
Jose Vicente Lidon-Roger
Eduardo Garcia-BreijoEduardo Garcia-Breijo
Eduardo Garcia-Breijo
There is an interest in new wearable solutions that can be directly worn on the curved human body or integrated into daily objects. Textiles offer properties that are suitable to be used as holders for electronics or sensors components. Many sensing technologies have been explored considering textiles substrates in combination with conductive materials in the last years. In this work, a novel solution of a gesture recognition touchless sensor is implemented with satisfactory results. Moreover, three manufacturing techniques have been considered as alternatives: screen-printing with conductive ink, embroidery with conductive thread and thermosealing with conductive fabric. The main critical parameters have been analyzed for each prototype including the sensitivity of the sensor, which is an important and specific parameter of this type of sensor. In addition, user validation has been performed, testing several gestures with different subjects. During the tests carried out, flick gestures obtained detection rates from 79% to 89% on average. Finally, in order to evaluate the stability and strength of the solutions, some tests have been performed to assess environmental variations and washability deteriorations. The obtained results are satisfactory regarding temperature and humidity variations. The washability tests revealed that, except for the screen-printing prototype, the sensors can be washed with minimum degradation.